Multifocused Ultrasound Therapy for Controlled Microvascular Permeabilization and Improved Drug Delivery.
Multifocused Ultrasound Therapy for Controlled Microvascular Permeabilization and Improved Drug Delivery.
复制标题
多聚焦超声治疗控制微血管渗透和改善药物传递。
DOI:
10.1109/tuffc.2020.3026697
复制
发表时间:
2021-04
期刊:
影响因子:
--
通讯作者:
Hoyt K
中科院分区:
文献类型:
--
作者:
Basavarajappa L;Rijal G;Hoyt K
Focused ultrasound (FUS) exposure of microbubble (MB) contrast agents can transiently increase microvascular permeability allowing anticancer drugs to extravasate into a targeted tumor tissue. Either fixed or mechanically steered in space, most studies to date have used a single element focused transducer to deliver the ultrasound (US) energy. The goal of this study was to investigate various multi-FUS strategies implemented on a programmable US scanner (Vantage 256, Verasonics Inc) equipped with a linear array for image guidance and a 128-element therapy transducer (HIFUPlex-06, Sonic Concepts). The multi-FUS strategies include multi-FUS with sequential excitation (multi-FUS-SE) and multi-FUS with temporal sequential excitation (multi-FUS-TSE) and were compared to single-FUS and sham treatment. This study was performed using athymic mice implanted with breast cancer cells (N = 20). FUS therapy experiments were performed for 10 min after a solution containing MBs (Definity, Lantheus Medical Imaging Inc) and near infrared (NIR, surrogate drug) dye were injected via the tail vein. Fluorescent signal was monitored using an in vivo optical imaging system (Pearl Trilogy, LI-COR) to quantify intratumoral dye accumulation at baseline and again at 0.1, 24, and 48 h after receiving US therapy. Animals were then euthanized for ex vivo dye extraction analysis. At 48 h, fluorescent tracer accumulation within the tumor space for the multi-FUS-TSE therapy group animals was found to be 67.3%, 50.3%, and 36.2% higher when compared to sham, single-FUS, and multi-FUS-SE therapy group measures, respectively. Also, dye extraction and fluorescence measurements from excised tumor tissue found increases of 243.2%, 163.1%, and 68.1% for the multi-FUS-TSE group compared to sham, single-FUS, and multi-FUS-SE therapy group measures, respectively. In summary, experimental results revealed that for a multi-FUS sequence, increased microvascular permeability was considerably influenced by both the spatial and temporal aspects of the applied US therapy.
影响因子:
2.9
作者:
Sorace, Anna G.;Warram, Jason M.;Mahoney, Marshall;Zinn, Kurt R.;Hoyt, Kenneth
通讯作者:
Hoyt, Kenneth