Diagnostic accuracy of two commercial SARS-CoV-2 antigen-detecting rapid tests at the point of care in community-based testing centers.

Diagnostic accuracy of two commercial SARS-CoV-2 antigen-detecting rapid tests at the point of care in community-based testing centers.
复制标题

DOI:
10.1371/journal.pone.0248921
复制
发表时间:
2021
期刊:
影响因子:
3.7
通讯作者:
Eckerle I
Eckerle I
中科院分区:
综合性期刊3区
文献类型:
--
作者:
Berger A;Nsoga MTN;Perez-Rodriguez FJ;Aad YA;Sattonnet-Roche P;Gayet-Ageron A;Jaksic C;Torriani G;Boehm E;Kronig I;Sacks JA;de Vos M;Bausch FJ;Chappuis F;Renzoni A;Kaiser L;Schibler M;Eckerle I

文献摘要

参考文献

被引文献

相似文献

Determine the diagnostic accuracy of two antigen-detecting rapid diagnostic tests (Ag-RDT) for SARS-CoV-2 at the point of care and define individuals’ characteristics providing best performance. We performed a prospective, single-center, point of care validation of two Ag-RDT in comparison to RT-PCR on nasopharyngeal swabs. Between October 9th and 23rd, 2020, 1064 participants were enrolled. The PanbioTM Covid-19 Ag Rapid Test device (Abbott) was validated in 535 participants, with 106 positive Ag-RDT results out of 124 positive RT-PCR individuals, yielding a sensitivity of 85.5% (95% CI: 78.0–91.2). Specificity was 100.0% (95% CI: 99.1–100) in 411 RT-PCR negative individuals. The Standard Q Ag-RDT (SD Biosensor, Roche) was validated in 529 participants, with 170 positive Ag-RDT results out of 191 positive RT-PCR individuals, yielding a sensitivity of 89.0% (95%CI: 83.7–93.1). One false positive result was obtained in 338 RT-PCR negative individuals, yielding a specificity of 99.7% (95%CI: 98.4–100). For individuals presenting with fever 1–5 days post symptom onset, combined Ag-RDT sensitivity was above 95%. Lower sensitivity of 88.2% was seen on the same day of symptom development (day 0). We provide an independent validation of two widely available commercial Ag-RDTs, both meeting WHO criteria of ≥80% sensitivity and ≥97% specificity. Although less sensitive than RT-PCR, these assays could be beneficial due to their rapid results, ease of use, and independence from existing laboratory structures. Testing criteria focusing on patients with typical symptoms in their early symptomatic period onset could further increase diagnostic value.
DOI: 10.1016/j.eclinm.2020.100677
发表时间: 2021-01
期刊: EClinicalMedicine
影响因子: 15.1
作者:
Gremmels H;Winkel BMF;Schuurman R;Rosingh A;Rigter NAM;Rodriguez O;Ubijaan J;Wensing AMJ;Bonten MJM;Hofstra LM
通讯作者: Hofstra LM
DOI: 10.1186/s12985-020-01452-5
发表时间: 2020-11-13
期刊: Virology journal
影响因子: 4.8
作者:
Chaimayo C;Kaewnaphan B;Tanlieng N;Athipanyasilp N;Sirijatuphat R;Chayakulkeeree M;Angkasekwinai N;Sutthent R;Puangpunngam N;Tharmviboonsri T;Pongraweewan O;Chuthapisith S;Sirivatanauksorn Y;Kantakamalakul W;Horthongkham N
通讯作者: Horthongkham N
DOI: 10.1038/s41591-020-0869-5
发表时间: 2020-04-15
期刊: NATURE MEDICINE
影响因子: 82.9
作者:
He, Xi;Lau, Eric H. Y.;Leung, Gabriel M.
通讯作者: Leung, Gabriel M.
DOI: 10.1016/j.cmi.2020.11.004
发表时间: 2021-03
期刊: Clinical microbiology and infection : the official publication of the European Society of Clinical Microbiology and Infectious Diseases
影响因子: --
作者:
Albert E;Torres I;Bueno F;Huntley D;Molla E;Fernández-Fuentes MÁ;Martínez M;Poujois S;Forqué L;Valdivia A;Solano de la Asunción C;Ferrer J;Colomina J;Navarro D
通讯作者: Navarro D
DOI: 10.1016/j.jcv.2020.104659
发表时间: 2020-12
期刊: Journal of clinical virology : the official publication of the Pan American Society for Clinical Virology
影响因子: --
作者:
Linares M;Pérez-Tanoira R;Carrero A;Romanyk J;Pérez-García F;Gómez-Herruz P;Arroyo T;Cuadros J
通讯作者: Cuadros J