A fully biodegradable polydioxanone occluder for ventricle septal defect closure.
A fully biodegradable polydioxanone occluder for ventricle septal defect closure.
复制标题
一种完全可生物降解的聚二恶酮闭塞剂用于室间隔缺损封闭。
DOI:
10.1016/j.bioactmat.2022.12.018
复制
发表时间:
2023-06
影响因子:
18.9
通讯作者:
Pan, Xiangbin
中科院分区:
文献类型:
--
作者:
Li, Zefu;Kong, Pengxu;Liu, Xiang;Feng, Shuyi;Ouyang, Wenbin;Wang, Shouzheng;Hu, Xiaopeng;Xie, Yongquan;Zhang, Fengwen;Zhang, Yuxin;Gao, Rui;Wang, Weiwei;Pan, Xiangbin
关键词:
Ventricular septal defect (VSD) is one of the commonest congenital heart diseases (CHDs). Current occluders for VSD treatment are mainly made of nitinol, which has the risk of nickel allergy, persistent myocardial abrasion and fatal arrythmia. Herein, a fully biodegradable polydioxanone (PDO) occluder equipped with a shape line and poly-l-lactic acid PLLA membranes is developed for VSD closure without the addition of metal marker. PDO occluder showed great mechanical strength, fatigue resistance, geometry fitness, biocompatibility and degradability. In a rat subcutaneous implantation model, PDO filaments significantly alleviated inflammation response, mitigated fibrosis and promoted endothelialization compared with nitinol. The safety and efficacy of PDO occluder were confirmed in a canine VSD model with 3-year follow-up, demonstrating the biodegradable PDO occluder could not only effectively repair VSD, induce cardiac remodeling but also address the complications associated with metal occluders. Furthermore, a pilot clinical trial with five VSD patients indicated that all the occluders were successfully implanted under the guidance of echocardiography and no adverse events occurred during the 3-month follow-up. Collectively, the fully bioresorbable PDO occluder is safe and effective for clinical VSD closure and holds great promise for the treatment of structural CHDs. Metal occluders may lead to complications due to permanent residues in the heart. PDO occluders mitigate inflammation response and promote endothelialization. 3-year follow-up of canine model testifies safety and efficacy of PDO occluders. PDO occluders were successfully implanted in 5 VSD patients.
登录
查看更多内容
影响因子:
3.4
作者:
Ou-Yang, Wen-Bin;Wang, Shou-Zheng;Pan, Xiang-Bin
通讯作者:
Pan, Xiang-Bin
DOI:
10.1080/00222349808220453
发表时间:
1998-01-01
期刊:
JOURNAL OF MACROMOLECULAR SCIENCE-PHYSICS
影响因子:
--
作者:
Ishikiriyama, K;Pyda, M;Wunderlich, B
通讯作者:
Wunderlich, B
影响因子:
5.5
作者:
Shah, Anand D.;Hirsh, David S.;Langberg, Jonathan J.
通讯作者:
Langberg, Jonathan J.
影响因子:
8.4
作者:
Pan, Maoen;Xu, Zeya;Huang, Heguang
通讯作者:
Huang, Heguang
影响因子:
24
作者:
Toumanides, Savvas;Sideris, Eleftherios B.;Moulopoulos, Spyridon
通讯作者:
Moulopoulos, Spyridon