Effects of putrefaction on the quantitative analyses of diphenhydramine in blood and tissues: model experiments by the routine matrix-matched calibration method and standard addition method with different internal standards
Effects of putrefaction on the quantitative analyses of diphenhydramine in blood and tissues: model experiments by the routine matrix-matched calibration method and standard addition method with different internal standards
复制标题
腐败对血液和组织中苯海拉明定量分析的影响:常规基质匹配校准法和不同内标标准添加法模型实验
DOI:
10.1007/s11419-021-00580-z
复制
发表时间:
2021
影响因子:
2.2
通讯作者:
Kubo Shin-ichi
中科院分区:
文献类型:
--
作者:
Kudo Keiko;Saka Kanju;Waters Brian;Hara Kenji;Matsusue Aya;Kashiwagi Masayuki;Kubo Shin-ichi
PurposeThe purpose of this study was to elucidate the effect of putrefaction on the quantitative analyses of diphenhydramine in blood and tissues by the routine matrix-matched calibration (MMC) method and the standard addition (SA) method for comparison.MethodsPutrefied samples were prepared by leaving pig blood, liver and muscle at room temperature. Toxic amounts of diphenhydramine and six internal standards (ISs) having different similarities were added to the prepared samples, and the drug was extracted with a liquid-liquid extraction method. The concentrations of diphenhydramine were determined by liquid chromatography–tandem mass spectrometry. The accuracies and precisions of the obtained quantitative values were compared in each quantification method. The results were also verified using human blood and tissues obtained at the time of autopsy.ResultsIn the MMC method, the deuterium-labeled IS showed good accuracies and precisions for putrefied samples. On the other hand, the concentrations of diphenhydramine using some non-isotopic ISs were found to deviate significantly from the true value.ConclusionsThe obtained results showed that the MMC method using fresh blood calibration curve with isotope-labeled IS could accurately measure drug concentrations in putrefied blood and tissues. If the isotope-labeled compound is not available, the quantification by the MMC method seems effective using several ISs with high similarity. This kind of study on the effects of putrefaction on forensic analyses has not been reported to our knowledge.
登录
查看更多内容
影响因子:
2.5
作者:
B. Reiter;T. Stimpfl
通讯作者:
T. Stimpfl
影响因子:
2.2
作者:
Amin Wurita;Koutaro Hasegawa;H. Nozawa;I. Yamagishi;K. Minakata;Kanako Watanabe;O. Suzuki
通讯作者:
O. Suzuki
影响因子:
1.5
作者:
Kiyotaka Usui;Yoshie Hayashizaki;M. Hashiyada;M. Funayama
通讯作者:
M. Funayama
影响因子:
2.5
作者:
M. Juhascik;A. Jenkins
通讯作者:
A. Jenkins