Optimization of a Concanavalin A-based glucose sensor using fluorescence anisotropy.

Optimization of a Concanavalin A-based glucose sensor using fluorescence anisotropy.
复制标题

DOI:
10.1021/ac303689j
复制
发表时间:
2013-06-04
影响因子:
7.4
通讯作者:
Cote, Gerard L.
Cote, Gerard L.
中科院分区:
化学1区
文献类型:
--
作者:
Cummins, Brian M.;Garza, Javier T.;Cote, Gerard L.

文献摘要

参考文献

被引文献

相似文献

To date, the dependent nature of the recognition and transduction mechanisms in optical glucose sensors based upon Concanavalin A (ConA) has tended to prevent the sensors’ full potential from being realized. In this paper, these mechanisms are independently optimized for a given assay configuration in order to decrease the predictive error of a ConA-based glucose sensor and to give a more accurate demonstration of its potential. To this end, we used fluorescence anisotropy as the transduction mechanism to determine the binding of ConA to 4 kDa FITC-dextran by measuring the change in the rotational correlation lifetime between the bound and unbound populations. By tracking the fluorescence anisotropy of this ligand, the ranges of ConA and 4 kDa FITC-dextran concentrations capable of being explored were not limited by the transduction mechanism. Using predetermined association constants, the binding responses to physiological glucose concentrations were predicted for different assay configurations, and experimentally collected fluorescence anisotropy data displayed the predicted trends for these assay configurations. From the experimental results, a calibration fit was generated for the optimized assay configuration to predict the glucose concentrations using the fluorescence anisotropy. This optimized assay displayed a mean standard error of prediction of 7.5 mg/dL (0–300 mg/dL), and 100% of the data points fell within clinically acceptable zones (A and B) upon the Clarke Error Grid Analysis. This indicates that, by independently optimizing the recognition and transduction mechanisms for the final assay configuration, the sensitivity of a competitive binding chemistry using ConA can be appropriately configured for continuous glucose monitoring applications.
DOI: 10.2337/diacare.10.5.622
发表时间: 1987-09-01
期刊: DIABETES CARE
影响因子: 16.2
作者:
CLARKE, WL;COX, D;POHL, SL
通讯作者: POHL, SL
DOI: 10.1016/0144-8617(90)90027-p
发表时间: 1990-01-01
影响因子: 11.2
作者:
CHEETHAM, NWH;FIALABEER, E;WALKER, GJ
通讯作者: WALKER, GJ
DOI: 10.1021/bi00171a014
发表时间: 1994-02-08
期刊: BIOCHEMISTRY
影响因子: 2.9
作者:
MANDAL, DK;KISHORE, N;BREWER, CF
通讯作者: BREWER, CF
DOI: 10.1016/0039-9140(88)80053-5
发表时间: 1988-02-01
期刊: TALANTA
影响因子: 6.1
作者:
MEADOWS, D;SCHULTZ, JS
通讯作者: SCHULTZ, JS
DOI: 10.1016/j.cbpa.2009.06.021
发表时间: 2009-10
影响因子: 7.8
作者:
Oyelaran, Oyindasola;Gildersleeve, Jeffrey C.
通讯作者: Gildersleeve, Jeffrey C.