An efficient rectangular optimization method for sparse orthogonal collimator based small animal irradiation.
An efficient rectangular optimization method for sparse orthogonal collimator based small animal irradiation.
复制标题
DOI:
10.1088/1361-6560/ac910b
复制
发表时间:
2022-09-28
影响因子:
3.5
通讯作者:
中科院分区:
文献类型:
--
作者:
Intensity-modulated radiotherapy (IMRT) is widely used in clinical radiotherapy, treating varying malignancies with conformal doses. As the test field for clinical translation, preclinical small animal experiments need to mimic the human radiotherapy condition, including IMRT. However, small animal IMRT is a systematic challenge due to the lack of corresponding hardware and software for miniaturized targets. The sparse orthogonal collimators (SOC) based on the direct rectangular aperture optimization (RAO) substantially simplified the hardware for miniaturization. This study investigates and evaluates a significantly improved RAO algorithm for complex mouse irradiation using SOC. Because the Kronecker product representation of the rectangular aperture is the main limitation of the computational performance, we reformulated matrix multiplication in the data fidelity term using multiplication with small matrices instead of the Kronecker product of the dose loading matrices. Solving the optimization problem was further accelerated using the Fast Iterative Shrinkage-Thresholding Algorithm (FISTA). Four mouse cases, including a liver, a brain tumor, a concave U-target, and a complex total marrow irradiation (TMI) case, were included in this study with manually delineated targets and OARs. Seven coplanar-field SOC IMRT (sIMRT) plans were compared with idealistic fluence map based IMRT (iIMRT) plans. For the first three cases with simpler and smaller targets, the differences between sIMRT plans and iIMRT plans in the planning target volumes (PTV) statistics are within 1%. For the TMI case, the sIMRT plans are superior in reducing hot spots (also termed Dmax) of PTV, kidneys, lungs, heart, and bowel by 20.5%, 31.5%, 24.67%, 20.13%, and 17.78%, respectively. On average, in four cases in this study, the sIMRT plan conformity is comparable to that of the iIMRT’s with lightly increased R50 and Integral Dose by 2.23% and 2.78%. The significantly improved sIMRT optimization method allows fast plan creation in under 1 minute for smaller targets and makes complex TMI planning feasible while achieving comparable dosimetry to idealistic IMRT with fluence map optimization.
登录
查看更多内容
影响因子:
64.5
作者:
Leder K;Pitter K;LaPlant Q;Hambardzumyan D;Ross BD;Chan TA;Holland EC;Michor F
通讯作者:
Michor F
影响因子:
24.1
作者:
Du, Shisuo;Chen, Genwen;Zeng, Zhaochong
通讯作者:
Zeng, Zhaochong
影响因子:
3.8
作者:
Earl, M. A.;Afghan, M. K. N.;Shepard, D. M.
通讯作者:
Shepard, D. M.
影响因子:
3.5
作者:
Das, Shiva K.;Ten Haken, Randall K.
通讯作者:
Ten Haken, Randall K.
影响因子:
3.8
作者:
Dan Nguyen;O'Connor, Daniel;Sheng, Ke
通讯作者:
Sheng, Ke