Fundamental Studies for the High Intensity Flash X-ray generators for Biomedical Radiography
Fundamental Studies for the High Intensity Flash X-ray generators for Biomedical Radiography
批准号:
60480256
负责人:
ISOBE Hiroshi
金额:
$4.03万
依托单位国家:
日本
项目类别:
Grant-in-Aid for General Scientific Research (B)
财政年份:
1985
资助国家:
日本
项目状态:
已结题
起止时间:
1985 至 1987
中文摘要
点击翻译按钮获取中文摘要
英文摘要
Fundamental studies for the high intensity flash x-ray generators for biomedical radiography are described. The single flash x-ray generators are as follows: (a) a high intensity type (less than 100kV) for performing the soft radiography, (b) a low-impedance and high intensity type (less than 120kV) for obtaining radiographs of tissues deep inside of the human body, and (c) a portable type (less than 200kV). Each generators had the control functions for the x-ray intensity, the spectrum distribution, and the effective focal spot size, and mainly consisted of the following essential components: a high voltage generator, a pulse condenser, a gas gap system, a turbo molecular pump, and a flash x-ray tube using field emission.Two types of the triple-pulsed x-ray generators consisted of the following components: a high-voltage generating unit, a voltage divider unit, three high-voltage generating unit, three high-voltage pulsers used for a portable generator, a tiple parallel impulse switch … More ing system, a high-power gas diode having three terminals, a turbo molecular pump, and three remote x-ray tubes having cold cathode. For the single-tube generator, the pulsers were charged to the same or different voltages by using a voltage divider unit and were connected to the x-ray tube through a high-power gas diode using SF_6. For the triple-tube generator,since three pulsers were connected directly to the tubes without a diode, three x-ray outputs could be obtained simultaneously. The minimum time intervals for the single-tube and the triple-tube types were about 100 and 3us, respectively. The x-ray intensities increased in proportion to the third or fourth power of the charging voltage. The pulse width was less than 300ns, and the x-ray quality (average spectrum distribution) became hard according to increases in the charging voltage and increases in the thickness of metal filters inserted outside of the x-ray window. The effective focal spot size could be reduced by decreasing the anode angle, decreasing the cathode diameter, decreasing the anode-cathode space, and inserting the metal filters.The high-speed radiographic system consisted of the following components: two types of delay switches,i. e. (a) direct switching and (b) laser switching, a delayed pulse generator, a CR system,and an FX generator. When the radiographic object triggered the delay switch, a short electric pulse was produced and was transmitted to the delayed pulse generator. An accurate delayed x-ray pulse was produced when the delayed pulse was transmitted to the high-speed impulse switching system. Next, when the radiographic object was exposed to the controlled x-rays under the optimum radiographic conditions, the permeating x-rays produced the digital image. Since the time resolutions for two types of delay switches were less than 20ns, the total time resolution for the x-ray production was less than 1<micrn>s. Various kinds of high speed biomedical radiography, e. g., the stroboscopic radiographgs, the continuous delayed radiographs the energy subtraction radiographs, and the continuous three-dimensional analysis could be performed by controlling the radiographic conditions. Less
期刊论文(38)
专著(0)
科研奖励(0)
会议论文
登录
查看更多内容
Eiichi Sato;Hiroshi Isobe;et al.: Jpn.J.Med.Imaging and Information Sci.3. 62-73 (1986)
Eiichi Sato;Hiroshi Isobe;et al.:Jpn.J.Med.Imaging and Information Sci.3。
DOI:
--
发表时间:
期刊:
影响因子:
--
作者:
[]
通讯作者:
Sato, E.;Isobe, H;Fujuyama, T.;Sato, S. et al.: Jpn. Radiol. Phys.7. 7-20 (1987)
Sato,E.;Isobe,H;Fujuyama,T.;Sato,S. 等人:Jpn。
DOI:
--
发表时间:
期刊:
影响因子:
--
作者:
[]
通讯作者:
Sato, E.;Isobe, H;Yanagisawa, T.: SPIE. 832. 180-187 (1988)
佐藤,E.;矶部,H;柳泽,T.:SPIE。
DOI:
--
发表时间:
期刊:
影响因子:
--
作者:
[]
通讯作者:
Eiichi Sato;Hiroshi Isobe;et al.: Rev.Sci.Instrum.57. 1399-1408 (1986)
Eiichi Sato;Hiroshi Isobe;等人:Rev.Sci.Instrum.57。
DOI:
--
发表时间:
期刊:
影响因子:
--
作者:
[]
通讯作者:
Sato, E.;Isobe, H;Hoshino, F.: Rev. Sci. Instrum.57. 1399-1408 (1986)
佐藤,E.;矶部,H;星野,F.:Rev. Sci。
DOI:
--
发表时间:
期刊:
影响因子:
--
作者:
[]
通讯作者:
共 19 条
Historical Study on the Underestimation and the Disregard 0f Arts and Crafts Education-The trial of paradoxical subject existence theory establishment
-
批准号:22530964
-
项目类别:Grant-in-Aid for Scientific Research (C)
-
资助金额:$2.58万
-
财政年份:2010
-
负责人:ISOBE Hiroshi
-
依托单位:
Research about the influence of E.P.Hughes gave to the current of thought on art education in this country after the later term of Meiji Era
-
批准号:16530580
-
项目类别:Grant-in-Aid for Scientific Research (C)
-
资助金额:$2.18万
-
财政年份:2004
-
负责人:ISOBE Hiroshi
-
依托单位:
STUDYABOUT THEART EDUCATION TREND OF THOUGHT OF MEIJI/TAISHO PERIOD - COLLECTION/UST MAKING OFAHISTORY DOCUMENT, ANALYSIS
-
批准号:13680290
-
项目类别:Grant-in-Aid for Scientific Research (C)
-
资助金额:$1.92万
-
财政年份:2001
-
负责人:ISOBE Hiroshi
-
依托单位:
熱水性炭酸塩鉱物の相関係と希土類元素の循環過程
-
批准号:11640483
-
项目类别:Grant-in-Aid for Scientific Research (C)
-
资助金额:$1.54万
-
财政年份:1999
-
负责人:ISOBE Hiroshi
-
依托单位:
Study on the multiple drug resistant mechanisms in clinical materials of lung cencer
-
批准号:07670646
-
项目类别:Grant-in-Aid for Scientific Research (C)
-
资助金额:$1.34万
-
财政年份:1995
-
负责人:ISOBE Hiroshi
-
依托单位:
海外基金