Development of a wearable pneumatic total artificial heart system aimed at permanent use
Development of a wearable pneumatic total artificial heart system aimed at permanent use
批准号:
20249059
负责人:
HOMMA Akihiko
金额:
$30.37万
依托单位国家:
日本
项目类别:
Grant-in-Aid for Scientific Research (A)
财政年份:
2008
资助国家:
日本
项目状态:
已结题
起止时间:
2008 至 2010
中文摘要
点击翻译按钮获取中文摘要
英文摘要
A wearable pneumatic total artificial heart (PTAH) system with compact wearable pneumatic drive (WPD) unit was developed. The PTAH system consists of left and right diaphragm-type blood pumps and two WPD units. Two blood pumps were designed to fit anatomy, and these had housing made of polyurethane resin. The sizes of the left and right pumps are 95 x 68 x 49 mm and 104 x 74 x 44 mm. The stroke volumes of the left and right pump are 85 and 94 ml, respectively. The WPD unit consists of a brushless DC motor, a crankshaft, a cylinder-piston, non-circular gears, and air pressure regulation valves. Driving air pressure is generated by the cylinder-piston. The non-circular gears generate the fixed systolic ratio. The size and weight of the WPD unit are 20 x 8.5 x 20 cm and 1.8 kg, respectively.The performance of the PTAH system was confirmed using an overflow-type mock circulation test. The pump output of more than 8 L/min using the left blood pump was achieved. The mean electric power consumption was approximately 20 W at 105bpm of pump rate.The fundamental performance of the PTAH system was evaluated in acute animal experiment. The left and right pumps were implanted in a calf weighing 98 kg. Two WPD units with fixed systolic ratio of 35 and 44% were connected to the left and right blood pumps with 2 m air hoses, respectively. The cardiac output ranged from 3.9 to 5.4 L/min at mean aorta pressures from 108 to 115 mmHg at pump rates from 60 to 100 bpm. The average electric power consumption in each WPD unit varied from 5.3 to 17.6 W according to the beating rate, and the efficiency was estimated from 2 to 9%.
期刊论文(37)
专著(0)
科研奖励(0)
会议论文
登录
查看更多内容
人工心臓の埋め込みに関するコンピュータシミュレーション技術
人工心脏植入计算机模拟技术
DOI:
--
发表时间:
2009
期刊:
電気学会研究会資料(リニアドライブ研究会) LD-09-38
影响因子:
--
作者:
[Doi N, Hoshi Y, Itokawa M, Usui C, Yoshikawa T, Tachikawa H, 鈴木聡, 黒澤雄,福井康裕,本間章彦,住倉博仁,大沼健太郎,巽英介,妙中義之]
通讯作者:
黒澤雄,福井康裕,本間章彦,住倉博仁,大沼健太郎,巽英介,妙中義之
Observation of cavitation pits on mechanical heart valve surface in an artificial heart used in in vitro testing
体外试验用人工心脏机械心脏瓣膜表面空化凹坑的观察
DOI:
--
发表时间:
2010
期刊:
J Artif Organs
影响因子:
1.3
作者:
[Ichiyama T, Matsushige T, Siba P, Suarkia D, Takasu T, Miki K, Furukawa S., Miki H, 鈴木聡, Hwangsung Lee]
通讯作者:
Hwangsung Lee
人工心臓の埋め込みシミュレーション技術の開発
人工心脏植入模拟技术的发展
DOI:
--
发表时间:
2010
期刊:
影响因子:
--
作者:
[三田満男, 本間章彦, 三田豊, 巽英介, 妙中義之, 福井康裕]
通讯作者:
福井康裕
恒久的使用を目的とした空気圧駆動式ウェアラブル全置換型人工心臓に関する基礎検討
永久使用气动驱动可穿戴全置换人工心脏的基础研究
DOI:
--
发表时间:
2009
期刊:
影响因子:
--
作者:
[本間章彦, 妙中義之, 巽英介, 住倉博仁, 大沼健太郎, 赤川英毅, 李桓成, 武輪能明, 水野敏秀, 築谷朋典, 片桐伸将, 角田幸秀, 下崎勇生, 向林宏, 片野一夫]
通讯作者:
片野一夫
人工臓器 □最近の進歩,人工心臓(基礎)
人工器官□最新进展,人工心脏(基础)
DOI:
--
发表时间:
2008
期刊:
人工臓器 37
影响因子:
--
作者:
[後藤昌史, 本間章彦]
通讯作者:
本間章彦
共 25 条
Development of a wearable pneumatic artificial heart system
-
批准号:23249065
-
项目类别:Grant-in-Aid for Scientific Research (A)
-
资助金额:$30.62万
-
财政年份:2011
-
负责人:HOMMA Akihiko
-
依托单位:
Development of the next generation implantable pneumatic ventricular assist device for permanent use.
-
批准号:17390356
-
项目类别:Grant-in-Aid for Scientific Research (B)
-
资助金额:$10.72万
-
财政年份:2005
-
负责人:HOMMA Akihiko
-
依托单位:
Development of a totally implantable ventricular assist device system with improved antithrombogenicity and portability
-
批准号:14370369
-
项目类别:Grant-in-Aid for Scientific Research (B)
-
资助金额:$8.83万
-
财政年份:2002
-
负责人:HOMMA Akihiko
-
依托单位:
海外基金