Valvo-Pump : Axial Blood Pump Implanted at the Heart Valve Position

瓣膜泵:植入心脏瓣膜位置的轴向血泵

基本信息

  • 批准号:
    01870061
  • 负责人:
  • 金额:
    $ 2.88万
  • 依托单位:
  • 依托单位国家:
    日本
  • 项目类别:
    Grant-in-Aid for Developmental Scientific Research (B).
  • 财政年份:
    1989
  • 资助国家:
    日本
  • 起止时间:
    1989 至 1990
  • 项目状态:
    已结题

项目摘要

The Valvo-Pump, axial nonpulsatile blood pump implanted at the heart valve position preserving the diseased heart muscle, has several advantages over artificial heart replacement. They are (a) good anatomical fitting to the natural heart, (b) less blood contacting surface, and (c) easy implantation technique as heart valve replacement. Feasibility of the concept of the Valvo-Pump was studied.The housing of the prototypical pump is a straight tube of 37 mm in diameter and 33 mm in length. Within the housing an impeller with 10 vanes is located. The impeller is connected to a samarium cobalt rare earth magnet DC brushless motor measuring 23.8 mm in diameter and 30.2 mm in length. Sealing is achieved by means of Teflon seal. A guiding wheel with four vanes is located behind the impeller.Pump was studied on a hydraulic mock circulation system to evaluate its performance characteristics. Pump flow of 5 l/min was obtained for the pump differential pressure of 90 mmHg at 4800 rpm, and 15 l/min for 70 mmHg at 4900 rpm.The Valvo-Pump will be feasible by developing a small high output power motor and an enduable seal and also by optimizing impeller design.
植入患病心肌的心脏瓣膜位置植入心脏瓣膜位置的Valvo-Pump,轴向非脉冲血泵,比人造心脏更换具有多个优势。它们是(a)对自然心脏的良好解剖结构,(b)较少的血接触表面,(c)易于植入技术作为心脏瓣膜更换。研究了Valvo-Pump的概念的可行性。原型泵的外壳是直径37毫米的直管,长度为33毫米。在房屋中,有10叶叶片的叶轮。叶轮连接到直径为23.8 mm的samarium钴稀土磁铁无刷电动机,长度为30.2毫米。密封是通过Teflon密封实现的。在叶轮后面,研究了一个带有四个叶片的引导轮。在液压模拟循环系统上研究了泵,以评估其性能特征。在4800 rpm处获得了90 mmHg的泵的差分为5 l/min的泵流量,在4900 rpm处获得70 mmHg的15 L/min,通过开发小型高输出动力电动机和一个可耐力的密封件,也可以通过优化插入器设计来可行。

项目成果

期刊论文数量(8)
专著数量(0)
科研奖励数量(0)
会议论文数量(0)
专利数量(0)
Mitamura Y, Yozu R, Tanaka T: "Valvo-Pump : Axial nonpulsatile blood pump implanted at the heart valve position." Artificial Heart. 3. (1991)
Mitamura Y、Yozu R、Tanaka T:“Valvo-Pump:植入心脏瓣膜位置的轴向非脉动血泵。”
  • DOI:
  • 发表时间:
  • 期刊:
  • 影响因子:
    0
  • 作者:
  • 通讯作者:
四津 良平: "新方式,人工心臓の開発ー超小型血液ポンプの心内埋め込みー" 日本臨床. 49. (1991)
Ryohei Yotsu:“人工心脏新方法的开发——超小型血泵的心内植入”日本临床49。(1991)
  • DOI:
  • 发表时间:
  • 期刊:
  • 影响因子:
    0
  • 作者:
  • 通讯作者:
Mitamura Y.,Yozu R.,Tanaka T.: "ValvoーPump:Axial nonpulsatile blood Pump implanted at the heart Valve position" Artificial Heart 3 SpringerーVerlarg. 3. (1991)
Mitamura Y.、Yozu R.、Tanaka T.:“瓣膜泵:植入心脏瓣膜位置的轴向非脉动血泵”Artificial Heart 3 Springer-Verlarg 3。 (1991)
  • DOI:
  • 发表时间:
  • 期刊:
  • 影响因子:
    0
  • 作者:
  • 通讯作者:
R.Yozu,Y.Mitamura,T.Tanaka.K,Yamazaki: "Toward a Totlly Implantable Artificial Heart:Axial Nonpulsatile Blood Pump Implanted at the Heart Valve Position (ValvoーPump)" ASAIO.37. (1991)
R.Yozu、Y.Mitamura、T.Tanaka.K、Yamazaki:“走向完全植入式人工心脏:植入心脏瓣膜位置的轴向非脉动血泵(ValvoPump)”ASAIO.37。
  • DOI:
  • 发表时间:
  • 期刊:
  • 影响因子:
    0
  • 作者:
  • 通讯作者:
Yoshinori Mitamura: "Valvo-Pump:Axial nonpulsatile blood pump implanted at the heart valve position" Artifical Heart 3-Springer-Verlag Tokyo. (1990)
Yoshinori Mitamura:“瓣膜泵:植入心脏瓣膜位置的轴向非脉动血泵”人工心脏 3-Springer-Verlag 东京。
  • DOI:
  • 发表时间:
  • 期刊:
  • 影响因子:
    0
  • 作者:
  • 通讯作者:
{{ item.title }}
{{ item.translation_title }}
  • DOI:
    {{ item.doi }}
  • 发表时间:
    {{ item.publish_year }}
  • 期刊:
  • 影响因子:
    {{ item.factor }}
  • 作者:
    {{ item.authors }}
  • 通讯作者:
    {{ item.author }}

数据更新时间:{{ journalArticles.updateTime }}

{{ item.title }}
  • 作者:
    {{ item.author }}

数据更新时间:{{ monograph.updateTime }}

{{ item.title }}
  • 作者:
    {{ item.author }}

数据更新时间:{{ sciAawards.updateTime }}

{{ item.title }}
  • 作者:
    {{ item.author }}

数据更新时间:{{ conferencePapers.updateTime }}

{{ item.title }}
  • 作者:
    {{ item.author }}

数据更新时间:{{ patent.updateTime }}

YOZU Ryohei其他文献

YOZU Ryohei的其他文献

{{ item.title }}
{{ item.translation_title }}
  • DOI:
    {{ item.doi }}
  • 发表时间:
    {{ item.publish_year }}
  • 期刊:
  • 影响因子:
    {{ item.factor }}
  • 作者:
    {{ item.authors }}
  • 通讯作者:
    {{ item.author }}

{{ truncateString('YOZU Ryohei', 18)}}的其他基金

Development of Implantable cardiac echo probe -Asa Monitor for Cardiac Surgery
开发植入式心脏超声探头-Asa 心脏手术监视器
  • 批准号:
    09557110
  • 财政年份:
    1997
  • 资助金额:
    $ 2.88万
  • 项目类别:
    Grant-in-Aid for Scientific Research (B)
Toward an implantable Axial intra-Cardiac Blood Pump : The Valvo-pump
开发植入式轴向心内血泵:Valvo 泵
  • 批准号:
    04557061
  • 财政年份:
    1992
  • 资助金额:
    $ 2.88万
  • 项目类别:
    Grant-in-Aid for Developmental Scientific Research (B)
A new bridging technique to heart transplantation (Tx)-Feasibility of monoventricularization (Monovent) of bilateral ventricles with LVAD
心脏移植(Tx)的新桥接技术——双侧心室左心室单心室化(Monovent)的可行性
  • 批准号:
    63480322
  • 财政年份:
    1988
  • 资助金额:
    $ 2.88万
  • 项目类别:
    Grant-in-Aid for General Scientific Research (B)

相似海外基金

The influences of size reduction of a Total Artificial Heart on fluid dynamics and blood compatibility.
全人工心脏尺寸减小对流体动力学和血液相容性的影响。
  • 批准号:
    2903462
  • 财政年份:
    2024
  • 资助金额:
    $ 2.88万
  • 项目类别:
    Studentship
SBIR Phase I: Development of novel artificial intelligence (AI)-enabled, non-invasive, heart attack diagnostics
SBIR 第一阶段:开发新型人工智能 (AI) 支持的非侵入性心脏病诊断
  • 批准号:
    2208248
  • 财政年份:
    2023
  • 资助金额:
    $ 2.88万
  • 项目类别:
    Standard Grant
Trustworthy Artificial Intelligence for Personalised Risk Assessment in Chronic Heart Failure
值得信赖的人工智能,用于慢性心力衰竭的个性化风险评估
  • 批准号:
    10078557
  • 财政年份:
    2023
  • 资助金额:
    $ 2.88万
  • 项目类别:
    EU-Funded
Artificial Intelligence for Dynamic, individualized CPR guidance: AID CPR
人工智能提供动态、个性化的心肺复苏指导:AID CPR
  • 批准号:
    10644648
  • 财政年份:
    2023
  • 资助金额:
    $ 2.88万
  • 项目类别:
Artificial Intelligence assisted echocardiography to facilitate optimal image extraction for congenital heart defects diagnosis in Sub-Saharan Africa
人工智能辅助超声心动图促进撒哈拉以南非洲先天性心脏缺陷诊断的最佳图像提取
  • 批准号:
    10710681
  • 财政年份:
    2023
  • 资助金额:
    $ 2.88万
  • 项目类别:
{{ showInfoDetail.title }}

作者:{{ showInfoDetail.author }}

知道了