Study of Scintillation Fiber Calorimeter for High Energy Particles

Study of Scintillation Fiber Calorimeter for High Energy Particles
高能粒子闪烁光纤量热仪的研究
批准号:
02044150
负责人:
TAKASAKI Fumihiko
金额:
$1.92万
依托单位国家:
日本
项目类别:
Grant-in-Aid for international Scientific Research
财政年份:
1990
资助国家:
日本
项目状态:
已结题
起止时间:
1990 至 --

项目摘要

项目成果

TAKASAKI Fumihiko的其他基金

相似基金

相关文献

中文摘要
翻译
点击翻译按钮获取中文摘要
英文摘要
Scintillation Fiber Calorimeter (SFCAL) is a calorimeter which has attracted interests as one of the detectors to be developed for high energy physics experiments in the coming years, especially at the multi-TeV hadron colliders such as SSC or LHC. We have been developing plastic scintillation fibers and a readout system of fiber calorimeter. A calorimeter module which we have been studying is 2.3 m long made of 1mm PHI scintillation fibers and lead. The proportion of scintillation fiber and lead is 1 to 4 in volume. The cross sections of the front and rear ends of the module are 4 x 4 cm and 8 X 8 cm. Protruding fibers at the rear end are bundled keeping the order of fibers in the lead. Bundled fibers are mirror-polished and connected to a multi-anode photomultiplier (MAPMT), Hamamatsu H4484. This MAPMT has 64 anodes and it makes it possible for us to study the features of the shower development in the material. We make nine modules and they are assembled in a 3 x 3 matrix forming a l … More arger calorimeter module. It weighs about 900Kg in total.Before studying this module for the high energy beam at CERN, we made a preliminary test of it on a few GeV electron beams produced at the TRISTAN Accumulation Ring for the following items.1) Treatment of output pulses with FADC2) Energy dependence of output signal3) Spread of shower in the module at its energy dependence4) Attenuation of the scintillation light in the module5) Interference of output pulse among the anodes6) Energy leakage between calorimeter modules7) Dependence of output pulse on the mechanical stress to the module8) Dependence of the output pulse on the incident beam angle9) Long term stability of the output pulseThe results are currently analyzed carefully. We confirmed that the light attenuation in the module depends critically on the glue used to assemble fibers and lead. It was first found by the collaborator at CERN. This fact will make us reconsider the way of fabrication of the calorimeter module in the next attempt. Less
期刊论文(4)
专著(0)
科研奖励(0)
会议论文
Takasaki Fumihiko et al: "Performance of Scintillation Fiber Calorimeter and Readout System with Multi-anode Photomultiplier Tibes" KEK Preprint (To be submitted to Nuclear Instruments and Methods). 89-183. (1990)
Takasaki Fumihiko 等人:“带有多阳极光电倍增管的闪烁光纤量热仪和读出系统的性能”KEK 预印本(将提交给核仪器和方法)。
DOI: --
发表时间:
期刊:
影响因子: --
作者: []
通讯作者:
高崎 史彦 他: "Performance of Scintillation Fiber Calorimeter and Readoutーsystem with Multiーanode Photomultiplier Tubes" KEK Preprint. 89ー183. (1990)
Fumihiko Takasaki 等人:“带有多阳极光电倍增管的闪烁光纤量热仪和读出系统的性能”KEK 89-183。
DOI: --
发表时间:
期刊:
影响因子: --
作者: []
通讯作者:
池田 博一 他: "Monolithic Shaper Amplifier for Multianode Readout" Nuclear Instruments and Methods. A292. 439-444 (1990)
Hirokazu Ikeda 等人:“用于多阳极读出的单片整形放大器”核仪器和方法439-444 (1990)。
DOI: --
发表时间:
期刊:
影响因子: --
作者: []
通讯作者:
Ikeda Hirokazu et al: "Monolithic shaper Amplifier for Multianode Readout" Nuclear Instruments and Methods. A292. 439-444 (1990)
Ikeda Hirokazu 等人:“用于多阳极读出的单片整形放大器”核仪器和方法。
DOI: --
发表时间:
期刊:
影响因子: --
作者: []
通讯作者:
Study of B-meson decays at the KEKB-Factory
Study of CP violation in B-meson decays
海外基金