Effects of scattered x rays upon radiographs used for computer-and diagnosis
散射 X 射线对用于计算机和诊断的放射线照片的影响
基本信息
- 批准号:08650072
- 负责人:
- 金额:$ 1.34万
- 依托单位:
- 依托单位国家:日本
- 项目类别:Grant-in-Aid for Scientific Research (C)
- 财政年份:1996
- 资助国家:日本
- 起止时间:1996 至 1997
- 项目状态:已结题
- 来源:
- 关键词:
项目摘要
Radiographs which are used for computer-aided diagnosis (CAD) should have enouth diagnositc information. Effects of scattered x rays upon radiographs were investigated for construting a CAD system.1.X-ray specturm measurementIt is important to know the properties of x rays emitted from an x-ray tube, for evaluating quality of radiographs and colent's exposure. Measuring method using a pure germanium detector, lead disks and an empirical collimator was established. Additionally, spectra of clinical x-ray apparatus were measured using a codmiumzinc telluride detector, which is paid attention as a new x-ray detector, and its usefulness was proved.2.Scatter fraction measurementA table equipped a moving grid system for experiment was developed. Using the table, we can exchange anti-scatter grid (grid hereafter) without moving experimental set-up. scatter fraction measuring method using a fluorescence-meter and lead^disks was established with the table.3.Evaluation of anti-scatter gridsPerformance of grids were investigated using Monte Carlo simulation. A new grid for bedside radiography was evaluated experimentally. As a result, it was clarified that the new gird was very useful when it was used under proper exposure conditions.4.Preparation for the construction of CAD system for swallowingFor the analysis of swallowing, an x-ray TV system, an imaging system, an image processing and archiving system and a chair for video fluorography were selecte. Pneumonia coused by miss swallowing was prevented under the observation with video fluoroscopy and video endoscopy.
用于计算机辅助诊断(CAD)的X线片应具有足够的诊断信息。本文研究了X射线散射对X射线照片的影响,为计算机辅助设计系统的研制提供了理论依据。1. X射线能谱测量了解X射线管发射的X射线的性质,对于评价X射线照片的质量和曝光量是很重要的。建立了用纯锗探测器、铅盘和经验准直器进行测量的方法。此外,还用一种新型的X射线探测器碲化锌钴探测器对临床X射线机的光谱进行了测量,并证明了它的实用性。2.散射分数测量研制了一个装有移动栅系统的实验台。使用该工作台,我们可以在不移动实验装置的情况下更换防散射滤线栅(以下简称滤线栅)。建立了用荧光计和铅盘测量散射分数的方法,并用表格表示。3.抗散射栅的评价用Monte Carlo模拟方法对栅的性能进行了研究。对一种新型床旁X线摄影滤线栅进行了实验评价。结果表明,当在适当的曝光条件下使用时,这种新的网格是非常有用的。4.吞咽CAD系统构建的准备对于吞咽的分析,选择了X射线电视系统、成像系统、图像处理和存档系统以及用于视频荧光造影的椅子。在电视透视和电视内窥镜观察下预防误吞咽引起的肺炎。
项目成果
期刊论文数量(3)
专著数量(0)
科研奖励数量(0)
会议论文数量(0)
专利数量(0)
瀧川 厚: "Cadmium Zinc Telluride検出器を用いた骨密度測定装置のX線スペクトル測定" 日本写真学会誌. 60. 196-199 (1997)
Atsushi Takikawa:“使用碲化镉锌探测器的骨密度测量装置的 X 射线光谱测量”日本摄影学会杂志 60. 196-199 (1997)。
- DOI:
- 发表时间:
- 期刊:
- 影响因子:0
- 作者:
- 通讯作者:
A.Takigawa, S.Nakamura, S.Nishihara, T.Iida and T.Sunayashiki: "X-ray spectrum measurement of bone mineral density apparatus using a cadmium zinc telluride detector" Journal of The Society of Photographic Science and Technology of Japan. 60(3). 196-199 (1
A.Takikawa、S.Nakamura、S.Nishihara、T.Iida 和 T.Sunayashiki:“使用碲化镉锌探测器进行骨矿物质密度 X 射线光谱测量”日本摄影科学技术学会杂志。
- DOI:
- 发表时间:
- 期刊:
- 影响因子:0
- 作者:
- 通讯作者:
瀧川 厚: "Cadmium Zinc Telluride 検出器を用いた骨密度測定装置のX線スペクトル測定" 日本写真学会誌. 60. 196-199 (1997)
Atsushi Takikawa:“使用碲化镉锌探测器的骨密度测量装置的 X 射线光谱测量”日本摄影学会杂志 60. 196-199 (1997)。
- DOI:
- 发表时间:
- 期刊:
- 影响因子:0
- 作者:
- 通讯作者:
{{
item.title }}
{{ item.translation_title }}
- DOI:
{{ item.doi }} - 发表时间:
{{ item.publish_year }} - 期刊:
- 影响因子:{{ item.factor }}
- 作者:
{{ item.authors }} - 通讯作者:
{{ item.author }}
数据更新时间:{{ journalArticles.updateTime }}
{{ item.title }}
- 作者:
{{ item.author }}
数据更新时间:{{ monograph.updateTime }}
{{ item.title }}
- 作者:
{{ item.author }}
数据更新时间:{{ sciAawards.updateTime }}
{{ item.title }}
- 作者:
{{ item.author }}
数据更新时间:{{ conferencePapers.updateTime }}
{{ item.title }}
- 作者:
{{ item.author }}
数据更新时间:{{ patent.updateTime }}
TAKIGAWA Atsushi其他文献
TAKIGAWA Atsushi的其他文献
{{
item.title }}
{{ item.translation_title }}
- DOI:
{{ item.doi }} - 发表时间:
{{ item.publish_year }} - 期刊:
- 影响因子:{{ item.factor }}
- 作者:
{{ item.authors }} - 通讯作者:
{{ item.author }}
{{ truncateString('TAKIGAWA Atsushi', 18)}}的其他基金
Effects of scattered X-rays on diagnostic X-ray images
散射 X 射线对诊断 X 射线图像的影响
- 批准号:
12650058 - 财政年份:2000
- 资助金额:
$ 1.34万 - 项目类别:
Grant-in-Aid for Scientific Research (C)
相似海外基金
Effects of scattered X-rays on diagnostic X-ray images
散射 X 射线对诊断 X 射线图像的影响
- 批准号:
12650058 - 财政年份:2000
- 资助金额:
$ 1.34万 - 项目类别:
Grant-in-Aid for Scientific Research (C)
Reduction of patient dose at medical x-ray diagnosis using scattered x rays.
使用散射 X 射线减少医疗 X 射线诊断中患者的剂量。
- 批准号:
08680524 - 财政年份:1996
- 资助金额:
$ 1.34万 - 项目类别:
Grant-in-Aid for Scientific Research (C)
Reduction of patient dose by using scattered x-rays
使用散射 X 射线减少患者剂量
- 批准号:
05680418 - 财政年份:1993
- 资助金额:
$ 1.34万 - 项目类别:
Grant-in-Aid for General Scientific Research (C)














{{item.name}}会员