项目摘要

项目成果

TAKEUCHI Shinichi的其他基金

相似基金

相关文献

中文摘要
翻译
本研究的目的是建立超声造影剂微泡对超声暴露响应的实验分析系统,阐明微泡结构与微泡对超声暴露响应的关系,包括非线性响应。此外,我们旨在开发利用微泡非线性行为的超声诊断系统和优化超声造影剂微泡性能的超声诊断系统。在硬脂酸钠、棕榈酸钠和皂素的混合溶液中鼓泡并加入氯化钙制备表面活性剂包覆的手制微泡,通过实验与理论结果的拟合,得到其壳弹性参数S_p为0.3 N/m,壳摩擦参数S_f为0.07 μNs/m。考虑微泡包覆膜的影响和微泡周围液体可压缩性的影响,通过非线性微分方程发现,用于谐波成像的最佳微泡具有较小的壳弹性参数和较大的壳摩擦参数。利用装有Langevine型超声换能器的不锈钢振动盘从水箱底部形成水中驻波声场,并将微泡保持在水中驻波声场回路对应的位置,制作了微泡行为观察系统。实验结果表明,与市售微泡超声造影剂相比,我们制备的表面活性剂包覆微泡更适合于谐波成像。利用超声诊断设备b型图像亮度的变化来估计微泡的寿命。进一步发现,适用于该微泡谐波成像的超声暴露条件为:(1)超声暴露频率与微泡谐振频率重合;(2)超声暴露频率与微泡谐振频率的一半重合。提出并研制了用于谐波成像和次谐波成像的双峰型超声换能器,并在此基础上验证了试制超声换能器的可行性。具有双峰型频率特性的超声换能器可以有效地辐射基波分量,检测二次谐波或次谐波分量,是利用微泡非线性特性优化超声诊断系统的关键器件。少
英文摘要
The purposes of this research are the development of experimental and analyzing system of response of microbubble ultrasound contrast agents to ultrasound exposure and clarification of the relation between the structure of microbubbles and response of microbubbles against ultrasound exposure including nonlinear response. Furthermore, we aimed at the development of ultrasound diagnostic system using nonlinear behavior of microbubbles and ultrasound diagnostic system optimizing the performance of microbubbles for ultrasound contrast agents.For these purpose, it was found that the shell elasticity parameter S_p was 0.3 N/m and the shell friction parameter S_f was 0.07 μNs/m by curve fitting between experimental and theoretical results with numerical calculation for the hand made surfactant coated microbubbles manufactured by bubbling in the mixed solution of sodium stearate, sodium palmitate and saponine and adding calcium chloride.It was found by nonlinear differential equation consideri … More ng the effect of coating membrane of microbubbles and the effect of compressibility of the liquid surrounding microbubbles proposed by us that the optimum microbubble for harmonic imaging has the small shell elasticity parameter and large shell friction parameter.The microbubble behavior observation systems by forming standing wave acoustic field in water from the bottom of water tank with stainless vibrating disc equipped with the Langevine type ultrasound transducer and by holding microbubbles at the position corresponding to the loop of standing wave acoustic field in water were manufactured.We can mention by these results that our hand made surfactant coated microbubbles were appropriate to harmonic imaging comparing with commercial microbubble ultrasound contrast agents.The life time of this microbubble was estimated with the change of brightness in the B-mode image of ultrasound diagnostic equipment. Furthermore, it was found that the ultrasound exposure condition appropriate to harmonic imaging with this microbubble were (1) to coincide between the ultrasound exposure frequency and the resonant frequency of microbubble and (2) to coincide between the ultrasound exposure frequency and the half of resonant frequency of microbubble.The ultrasound transducers with double peak type frequency characteristics for harmonic imaging and those for subharmonic imaging were proposed and developed and the availability of these trially manufactured ultrasound transducers were confirmed on the basis of these results. As the fundamental ultrasound component can be radiated and the second harmonic component or subharmonic component can be detected effectively by these ultrasound transducers with double peak type frequency characteristics, these ultrasound transducers can be thought as the key device for optimum ultrasound diagnostic system using nonlinear behavior of microbubbles. Less
期刊论文(25)
专著(0)
科研奖励(0)
会议论文
Shinichi Takeuchi: "Nonlinear response of microbubbles coated with surfactant membrane developed as ultrasound contrast agent -experimental study and numerical calculations-"Colloids and Surfaces B : Biointerfaces. (2002)
Shinichi Takeuchi:“作为超声造影剂开发的涂有表面活性剂膜的微泡的非线性响应 - 实验研究和数值计算 -”胶体和表面 B:生物界面。
DOI: --
发表时间:
期刊:
影响因子: --
作者: []
通讯作者:
Shinichi Takeuchi: "Development of ultrasound transducer with double peak type frequency characteristics for harmonic imaging ultrasound diagnostic equipment"Proceedings of IEEE Ultrasonic Symposium in Atlanta. 1151-1155 (2002)
Shinichi Takeuchi:“开发用于谐波成像超声诊断设备的具有双峰型频率特性的超声换能器”亚特兰大 IEEE 超声研讨会论文集。
DOI: --
发表时间:
期刊:
影响因子: --
作者: []
通讯作者:
Shinichi Takeuchi: "Detection of harmonic ultrasound scattered from microbubbles with ultrasound transducer for harmonic imaging having double peak type frequency characteristics"Colloids and Surfaces B : Biointerfaces. (2002)
Shinichi Takeuchi:“用超声波传感器检测从微泡散射的谐波超声波,用于具有双峰型频率特性的谐波成像”胶体和表面 B:生物界面。
DOI: --
发表时间:
期刊:
影响因子: --
作者: []
通讯作者:
Takeuchi,Shinichi, Soetanto,Kawan, Sato,Toshio and Kawashima,Norimichi: "Optimum ultrasounc exposure condition for excitation of nonlinear behavior of microbubbles coated with surfactant"Acoustical Science and Technology. Vol. 22, no. 5. 364-366 (2001)
Takeuchi、Shinichi、Soetanto、Kawan、Sato、Toshio 和 Kawashima、Norimichi:“激发表面活性剂包覆微泡非线性行为的最佳超声暴露条件”声学科学与技术。
DOI: --
发表时间:
期刊:
影响因子: --
作者: []
通讯作者:
共 21 条
    Basic research of ultra-miniature medical ultrasound transducer by hydrothermal method
    • 批准号:
      17500339
    • 项目类别:
      Grant-in-Aid for Scientific Research (C)
    • 资助金额:
      $2.46万
    • 财政年份:
      2005
    • 负责人:
      TAKEUCHI Shinichi
    • 依托单位:
    海外基金