Research on high sensitive handy ELISA system for multi-environmental analysis using 3D micro fluidic networks
利用3D微流体网络进行多环境分析的高灵敏度便携式ELISA系统的研究
基本信息
- 批准号:20510015
- 负责人:
- 金额:$ 2.91万
- 依托单位:
- 依托单位国家:日本
- 项目类别:Grant-in-Aid for Scientific Research (C)
- 财政年份:2008
- 资助国家:日本
- 起止时间:2008 至 2010
- 项目状态:已结题
- 来源:
- 关键词:
项目摘要
There have been paid much attention to the lab-on-a-CD for the use of enazyme-linked immunosorbent assay (ELISA), due to its convenience for the automation of multiple microreactors [1-2]. However it is difficult to simultaneously realize the performance and integration of multiple reactor units due to the limited chip area. One of the biggest problem arise from the limitation is inadequate sensitivity due to shortage of surface area for the immobilization of antibody. we propose a new type lab-on-a-CD concept based on three-dimensional (3D) microchannel network. This paper reports high-sensitive detection of poly-chlorinatedbiphenyl (PCB) by using bundle-like capillary structure on a 3D lab-on-a-CD.
酶联免疫吸附试验(ELISA)的实验室-a-CD由于其便于多个微反应器的自动化而受到广泛关注[1-2]。然而,由于芯片面积有限,难以同时实现多个反应器单元的性能和集成。由该限制引起的最大问题之一是由于用于固定抗体的表面积不足而导致灵敏度不足。我们提出了一种基于三维微通道网络的新型光盘实验室概念。本文报道了在3D光盘实验室上利用仿十字形毛细管结构实现多氯联苯(PCB)的高灵敏检测。
项目成果
期刊论文数量(0)
专著数量(0)
科研奖励数量(0)
会议论文数量(0)
专利数量(0)
Enzyme-Linked Immunosorbent Assay using Antibody Bound Fluoroplastic Microstructure
使用抗体结合的氟塑料微结构进行酶联免疫吸附测定
- DOI:
- 发表时间:2009
- 期刊:
- 影响因子:0
- 作者:Y.Ukita;S.Kondo;T.Azeta;C.Kataoka;M.Takeo;S.Negoro;Y.Utsumi
- 通讯作者:Y.Utsumi
High Efficiency Mixing by the Use of Cross-Linked Micro Capillary Fluid Filter
使用交联微毛细管流体过滤器进行高效混合
- DOI:
- 发表时间:2008
- 期刊:
- 影响因子:0
- 作者:Kuniyo Fujiwara;Yoshiaki Ukita;Masahiro Takeo;Seiji Negoro;Tomohiko Kanie;MakotoKatayama;Yuichi Utsumi
- 通讯作者:Yuichi Utsumi
Fabrication of Polytetrafluoroethylene microparts by High-Energy X-ray Induced Etching
高能 X 射线诱导蚀刻制备聚四氟乙烯微型零件
- DOI:
- 发表时间:2008
- 期刊:
- 影响因子:0
- 作者:Yoshiaki Ukita;Mitsuyoshi Kishihara;Yuichi Haruyama;Kazuhiro Kanda;Shinji Matsui;Kozo Michiji;Yuichi Utsumi
- 通讯作者:Yuichi Utsumi
Vertical Microreactor Stack Consist of poly-(tetrafluoroethylene) Micro fluidics for Immunoassay
由聚(四氟乙烯)微流体组成的垂直微反应器堆栈,用于免疫分析
- DOI:
- 发表时间:2010
- 期刊:
- 影响因子:0
- 作者:Yoshiaki Ukita;Saki Kondo;Masahiro Takeo;Seiji Negoro;Chiwa Kataoka;Yuichi Utsumi
- 通讯作者:Yuichi Utsumi
Three-dimensional Centrifugal Microfluidics for Environmenatal Analysis
用于环境分析的三维离心微流控
- DOI:
- 发表时间:2010
- 期刊:
- 影响因子:0
- 作者:Yosyiaki Ukita;Tsukasa Azeta;Saki Kondo;Chiwa Kataoka;Shinichi Yusa;Masahiro Takeo;Yuichi Utsumi
- 通讯作者:Yuichi Utsumi
{{
item.title }}
{{ item.translation_title }}
- DOI:
{{ item.doi }} - 发表时间:
{{ item.publish_year }} - 期刊:
- 影响因子:{{ item.factor }}
- 作者:
{{ item.authors }} - 通讯作者:
{{ item.author }}
数据更新时间:{{ journalArticles.updateTime }}
{{ item.title }}
- 作者:
{{ item.author }}
数据更新时间:{{ monograph.updateTime }}
{{ item.title }}
- 作者:
{{ item.author }}
数据更新时间:{{ sciAawards.updateTime }}
{{ item.title }}
- 作者:
{{ item.author }}
数据更新时间:{{ conferencePapers.updateTime }}
{{ item.title }}
- 作者:
{{ item.author }}
数据更新时间:{{ patent.updateTime }}
UTSUMI Yuichi其他文献
UTSUMI Yuichi的其他文献
{{
item.title }}
{{ item.translation_title }}
- DOI:
{{ item.doi }} - 发表时间:
{{ item.publish_year }} - 期刊:
- 影响因子:{{ item.factor }}
- 作者:
{{ item.authors }} - 通讯作者:
{{ item.author }}
{{ truncateString('UTSUMI Yuichi', 18)}}的其他基金
Research on Full-protocol Disease Marker Screening System using Integrated Lab-on-a-CD for Immunoassay
使用集成Lab-on-a-CD进行免疫分析的全方案疾病标志物筛查系统的研究
- 批准号:
23350035 - 财政年份:2011
- 资助金额:
$ 2.91万 - 项目类别:
Grant-in-Aid for Scientific Research (B)
Research on micro environmental analysis using stacked miniaturized 3D chemical system
堆叠式微型3D化学系统微环境分析研究
- 批准号:
16550083 - 财政年份:2004
- 资助金额:
$ 2.91万 - 项目类别:
Grant-in-Aid for Scientific Research (C)














{{item.name}}会员




