课题基金 / 基金详情

Development of a potable ELISA machine using novel antigen-bound polymer

Development of a potable ELISA machine using novel antigen-bound polymer
使用新型抗原结合聚合物开发便携式 ELISA 机器
批准号:
23510146
负责人:
TAKEO MASAHIRO
金额:
$3.58万
依托单位:
依托单位国家:
日本
项目类别:
Grant-in-Aid for Scientific Research (C)
财政年份:
2011
资助国家:
日本
项目状态:
已结题
起止时间:
2011 至 2013

项目摘要

项目成果

相似基金

相关文献

中文摘要
翻译
我们开发了一种便携式酶联免疫吸附测定仪的测量内分泌干扰物,壬基酚。将由具有壬基苯基作为侧链的PMMA基聚合物制成的微过滤器设置在垂直堆叠的微反应器中。将微反应器安装在一个25 cm立方体的新开发的自动化流体和检测系统中,并使用该小系统进行竞争ELISA。在0.01-1.00 μ g/l浓度范围内,可建立一条负相关的标准曲线,所得数据的平均变异系数为4.2%。这些结果与商业灵敏分析仪器的灵敏度和重复性相当。
英文摘要
We developed a portable ELISA machine for the measurement of an endocrine disruptor, nonylphenol. A microfilter, which was made from PMMA-based polymer with nonylphenyl group as a side chain, was set in a vertically-stacked microreactor. The microreactor was set in a newly-developed automatic fluidic and detection system in a 25cm-cubic case and competitive ELISA was performed using this small system. As a result, we could construct a good standard curve with negative correlation in a concentration range of 0.01-1.00 microgram/l and the average coefficient of variation of the data obtained was 4.2%. These results were comparable to the sensitivity and repeatability of commercial sensitive analytical machines.
期刊论文(0)
专著(0)
科研奖励(0)
会议论文
Development of a portable fluidic and detection system for ELISA in a 3-dimentional microreactor
三维微反应器中用于 ELISA 的便携式流体和检测系统的开发
DOI: --
发表时间: 2013
期刊:
影响因子: --
作者: [M. Takeo, S. Nii, D.Kato, S. Negoro, S. Yusa, T. Saiki, Y. Takizawa, and Y. Utsumi]
通讯作者: and Y. Utsumi
Development of a Portable Fluidic and Detection System for ELISA in a 3-Dimensional Microreactor
3 维微反应器中 ELISA 便携式流体和检测系统的开发
DOI: --
发表时间: 2013
期刊:
影响因子: --
作者: [Masahiro Takeo Shoichi Nii, Dai-ichiro Kato, Seiji Negoro, Shinichi Yusa, Tsunemasa Saiki, Yukako Takizawa, Yuichi Utsumi]
通讯作者: Yuichi Utsumi
Development of automatic ELISA analytical system for a trace amount of nonylphenol7using a novel antigen-bound microfilter
使用新型抗原结合微过滤器开发痕量壬基酚7自动ELISA分析系统
DOI: --
发表时间: 2013
期刊:
影响因子: --
作者: [M. Takeo, I. Kawaji, A. Nakasuji, T. Tone, Y. Ukita, D. Kato, S. Negoro, S. Yusa, M. Katayama, and Y. Utsumi]
通讯作者: and Y. Utsumi
Automatic ELISA analytical system for a trace amount of environmental chemicals using a 3-dimensional microreactor with a novel antigen-bound microfilter
使用带有新型抗原结合微过滤器的 3 维微反应器对微量环境化学物质进行自动 ELISA 分析系统
DOI: --
发表时间: 2012
期刊:
影响因子: --
作者: [M. Takeo, I. Kawaji, A. Nakasuji, T. Tone, Y.Ukita, D. Kato, S. Negoro, S. Yusa, M. Katayama, and Y.Utsumi]
通讯作者: and Y.Utsumi
7