Study for gaining detector sensitivity by making the detector in a long shape on the high performance PET detector which consists of semiconductor photo-detectors

Study for gaining detector sensitivity by making the detector in a long shape on the high performance PET detector which consists of semiconductor photo-detectors
在由半导体光电探测器组成的高性能PET探测器上将探测器制成长形以提高探测器灵敏度的研究
批准号:
23602017
负责人:
INADAMA Naoko
金额:
$3.33万
依托单位国家:
日本
项目类别:
Grant-in-Aid for Scientific Research (C)
财政年份:
2011
资助国家:
日本
项目状态:
已结题
起止时间:
2011 至 2013

项目摘要

项目成果

INADAMA Naoko的其他基金

相似基金

相关文献

中文摘要
翻译
点击翻译按钮获取中文摘要
英文摘要
Positron emission tomography (PET) is a method to image distribution of substance in a body and often used in medical field. For example, specific accumulations observed in an image of glucose distribution indicate exist of tumors. Such PET image is obtained by injecting radioisotope (RI) of the substance and detecting the radiations from the RI at outside the body so that the image quality is much depends on performance of the radiation detectors. Our research team was developed the high performance PET detector which could be realized by recent popularization of small photo-detector devices. In this study, it was proved that, aiming for gaining the detector sensitivity, extension of the detector volume in one direction (a long shape) was possible with maintaining detector spatial resolution. Also, it was found that the new trials in fabrication, the use of plate scintillators for high yield rate and laser processing, were effective.
期刊论文(0)
专著(0)
科研奖励(0)
会议论文
X'tal cube detector composed of a stack of scintillator plates segmented by laser processing
Xtal 立方体探测器由一堆通过激光加工分段的闪烁体板组成
DOI: --
发表时间: 2012
期刊:
影响因子: --
作者: [Arun Prasath Lakshmanan, Watanabe K et al., 稲玉直子]
通讯作者: 稲玉直子
レーザー分割シンチレータのクリスタルキューブPET検出器:3D加工法と2D加工法の比較
激光分光闪烁体晶体立方体PET探测器:3D和2D加工方法的比较
DOI: --
发表时间:
期刊:
影响因子: --
作者: [Arumugam S, Watanabe K et al., 稲玉 直子]
通讯作者: 稲玉 直子
Performance evaluation of the X'tal cube PET detector using a monolithic scintillator segmented by laser processing
使用激光加工分段的单片闪烁体对 Xtal 立方体 PET 探测器进行性能评估
DOI: --
发表时间: 2011
期刊:
影响因子: --
作者: [Somasundaram Arumugam, Watanabe K et al., 稲玉直子]
通讯作者: 稲玉直子
Study about position calculation for the DOI-PET detector 2nd SNU-NIRS Workshop on Nuclear Medicine Imaging Science and Technology
DOI-PET探测器位置计算研究第二届SNU-NIRS核医学成像科学与技术研讨会
DOI: --
发表时间:
期刊:
影响因子: --
作者: [Arumugam S, Watanabe K et al., Naoko Inadama]
通讯作者: Naoko Inadama
16
    Investigation of a high performance DOI-PET detector by using the scintillation crystals cut as triangular prisms
    海外基金