课题基金 / 基金详情

Development of process spectroscopy tomography method for diagnosis of lymphedema

Development of process spectroscopy tomography method for diagnosis of lymphedema
诊断淋巴水肿的过程光谱断层扫描方法的发展
批准号:
16J08769
负责人:
バイディラ ラマダン マルリン
金额:
$1.47万
依托单位:
依托单位国家:
日本
项目类别:
Grant-in-Aid for JSPS Fellows
财政年份:
2016
资助国家:
日本
项目状态:
已结题
起止时间:
2016-04-22 至 2018-03-31

项目摘要

项目成果

相似基金

相关文献

中文摘要
翻译
Research results 29年4月~30年3月1.A permittivity range of biological tissue is very high and cannot covered by the current capacitance measurement system. In order to allow electrical capacitance tomography can visualize the pathology and physiological condition inside human body, a new scanning method is proposed based on four-electrodes measurement in low-voltage and low-frequency capacitance measurement.2.The patient’s upper arm have different diameter condition among Lymphedema stages. The aim of this research is to develop an adjustable EIT sensor, which can be adjustable diameter of the sensor within a certain range therefore the electrode gap-to-diameter ratio (EDR) of the sensor is changed. A prototype EIT sensor with adjustable diameter and consists of 32 electrodes is manufactured and evaluated through experimental studies. The experimental results show that the EIT sensor with adjustable diameter can provide similar reconstructed images to a traditional EIT sensor which has a fixed diameter.3.The acquisition measurement system based on FPGA and 32 electrodes attached to active electrodes circuit has been developed to establish a simultaneously dielectric dispersion measurement within 928 measurement pairs.4.The clinical study with volunteer of Lymphedema could not be conducted during April 2017 to March 2018 due technical problem in data acquisition system. During this time, a prototype system was evaluated based on phantom objects and volunteers with normal condition. The research results of volunteers with normal condition are not published yet.
英文摘要
Research results 29年4月~30年3月1.A permittivity range of biological tissue is very high and cannot covered by the current capacitance measurement system. In order to allow electrical capacitance tomography can visualize the pathology and physiological condition inside human body, a new scanning method is proposed based on four-electrodes measurement in low-voltage and low-frequency capacitance measurement.2.The patient’s upper arm have different diameter condition among Lymphedema stages. The aim of this research is to develop an adjustable EIT sensor, which can be adjustable diameter of the sensor within a certain range therefore the electrode gap-to-diameter ratio (EDR) of the sensor is changed. A prototype EIT sensor with adjustable diameter and consists of 32 electrodes is manufactured and evaluated through experimental studies. The experimental results show that the EIT sensor with adjustable diameter can provide similar reconstructed images to a traditional EIT sensor which has a fixed diameter.3.The acquisition measurement system based on FPGA and 32 electrodes attached to active electrodes circuit has been developed to establish a simultaneously dielectric dispersion measurement within 928 measurement pairs.4.The clinical study with volunteer of Lymphedema could not be conducted during April 2017 to March 2018 due technical problem in data acquisition system. During this time, a prototype system was evaluated based on phantom objects and volunteers with normal condition. The research results of volunteers with normal condition are not published yet.
期刊论文(0)
专著(0)
科研奖励(0)
会议论文
武居研究室
武井研究所
DOI: --
发表时间:
期刊:
影响因子: --
作者: []
通讯作者:
Impedance Spectroscopy for Lymphedema Detection
用于淋巴水肿检测的阻抗谱
DOI: --
发表时间: 2016
期刊:
影响因子: --
作者: [Baidillah, M. R.*, Sun, Y., Takahiro, S. & Takei, M.]
通讯作者: M.
DOI: --
发表时间: 2016
期刊:
影响因子: --
作者: [Baidillah, M. R.* and Takei, M.]
通讯作者: M.
Equivalent Circuit Analysis of EIS using Tomography Sensor
使用断层扫描传感器的 EIS 等效电路分析
DOI: --
发表时间: 2016
期刊:
影响因子: --
作者: [Sun, Y.*, Baidillah, M. R. and Takei, M.]
通讯作者: M.
10