课题基金 / 基金详情

Design and Characterization of a Blackbody for the calibration of non-contact medical thermometers

Design and Characterization of a Blackbody for the calibration of non-contact medical thermometers
用于校准非接触式医用温度计的黑体的设计和表征
批准号:
10074441
负责人:
金额:
$0.39万
依托单位国家:
英国
项目类别:
Collaborative R&D
财政年份:
2023
资助国家:
英国
项目状态:
已结题
起止时间:
2023 至 --

项目摘要

项目成果

相似基金

相关文献

中文摘要
翻译
耳温计在临床环境中广泛用于测量患者体温,而前额温度计在大流行期间越来越多地用作发热筛查方法。为了进行可靠的体温测量,需要通过使用合适的黑体源进行校准来验证设备的性能。对于合适的源,它必须具有足够高的发射率,足够大的开口以完全填充温度计的视场,良好的温度均匀性和测量温度的方法,可追溯到1990年国际温标(ITS-90)。BIPM咨询委员会已在国际上认同有需要更深入了解额温计和耳温计的性能和校正方法。温度测量委员会(CCT)- [https://www.bipm.org/en/committees/cc/cct/guides-to-thermometry][0] ISO 80601-2-56:2017标准提供了合适黑体源的规格,但这些规格基于使用相对繁琐的搅拌液体浴。设计和开发一种具有所需规格的黑体,但不依赖于水浴,将为用户提供更实用的耳温计和前额温度计校准解决方案,并有助于确保它们适合预期用途。我们现有一系列用于校准非接触式温度计的产品,但这些产品主要是为更通用的红外温度计而设计的,而不是医用温度计。对医用温度计的实验室性能以及用于校准它们的黑体源的要求往往更加严格,在没有进一步研究的情况下,尚不清楚Isotech的黑体源是否适用于当前设计的医用温度计的校准。与NPL合作,Isotech将能够确定现有校准器对这些医用温度计的适用性,通过分析和建模,我们可以了解最佳的几何形状,然后获得性能的证据。然后,我们将能够通过我们的全球分销网络将我们的产品销售到英国和海外的新市场。拥有一个便携式产品,已知的性能,将使用户能够对设备进行常规校准。[0]:https://www.bipm.org/en/committees/cc/cct/guides-to-thermometry网站
英文摘要
Ear thermometers are widely used in a clinical setting for the measurement of patient temperature, whereas forehead thermometers have been increasingly used during the pandemic as a method of fever screening. For reliable body temperature measurement, the performance of the devices needs to be validated by calibration using a suitable blackbody source. For a source to be suitable it must have a sufficiently high emissivity, sufficiently large opening to completely fill the field-of-view of the thermometer, good temperature uniformity and a means to measure the temperature which is traceable to the International Temperature Scale of 1990 (the ITS-90).The need for better understanding of the performance and calibration of both forehead and ear thermometers has been recognised internationally by the BIPM Consultative Committee for Thermometry (CCT) - [https://www.bipm.org/en/committees/cc/cct/guides-to-thermometry][0]The ISO 80601-2-56:2017 standard provides the specifications for suitable blackbody sources, but these are based on stirred liquid baths which are relatively cumbersome to use. Designing and developing a blackbody which has the required specifications, but which does not rely on a water bath, would provide users with a more practical solution for the calibration of ear and forehead thermometers and help ensure they are fit for the intended use.We have a range of existing products used to calibrate non-contact thermometers but these are primarily designed for the more generic infrared thermometers, not medical thermometers. The requirements for the laboratory performance of medical thermometers, and hence the blackbody sources used to calibrate them, tend to be more stringent, and it is not clear, without further study, whether or not Isotech's sources are suitable for the calibration of medical thermometers in their current design.Working with NPL, Isotech will be able to determine the suitability of an existing calibrator for these medical thermometers, from analysis and modeling we can learn of the optimal geometry and then have evidence of the performance.Then we will be able to sell our product into a new market both in the UK and overseas via our global distribution network.Having a portable product, of known performance, will enable routine calibration of the devices by users.[0]: https://www.bipm.org/en/committees/cc/cct/guides-to-thermometry
期刊论文(0)
专著(0)
科研奖励(0)
会议论文
海外基金