Wearable Micro-Structured Tonometric Sensor Patches for 24-Hour Ambulatory Blood Pressure Monitoring
Wearable Micro-Structured Tonometric Sensor Patches for 24-Hour Ambulatory Blood Pressure Monitoring
批准号:
10509575
负责人:
Feng Xiong
金额:
$14.68万
依托单位国家:
美国
项目类别:
财政年份:
2022
资助国家:
美国
项目状态:
未结题
起止时间:
2022-09-01 至 2025-05-31
关键词:
AccelerometerAchievementAddressAdhesionsAgeAmbulatory Blood Pressure MonitoringBlood PressureBlood Pressure MonitorsCalibrationCardiovascular DiseasesClinicClinicalDevicesDiagnosisDiastolic blood pressureDistalEffectivenessElectrocardiogramEthnic OriginGenderGenerationsGeometryGoldHeartHourHumanHypertensionHypotensionIonsLeadLiquid substanceMeasurementMeasuresMethodsMonitorMorphologic artifactsMyocardial InfarctionNoiseOperative Surgical ProceduresOutcomePatientsPeriodicityPhotoplethysmographyPhysiologic pulsePostural adjustmentsReadingResearchRisk FactorsShapesSignal TransductionSiteSkinSleepStrokeStructureSupinationSurfaceSystemTechnologyTimeTranslatingTravelWorkarterial tonometrybasecardiovascular risk factorclinical practicecovalent bondcrosslinkdesignfoothuman subjecthypertensiveimprovedinnovationmonitoring devicemortalitynormotensivenoveloperationpressuresensortemporal measurementwearable devicewearable sensor technologywireless
中文摘要
点击翻译按钮获取中文摘要
英文摘要
PROJECT SUMMARY/ABSTRACT
High blood pressure (BP) is the single largest risk factor for cardiovascular disease mortality. Due to the well-
known limitations of clinic BP measurement, 24-hour ambulatory BP monitoring with automatic cuff devices
has emerged as the gold standard method for hypertension diagnosis. Due to periodic inflation and deflation
even at nighttime, the cuff devices are disruptive to patients and could diminish the clinical value of nighttime
BP. Hence, cuff-less BP monitoring devices are being widely pursued. Pulse transit time (PTT), the time delay
for the pressure wave to travel between two arterial sites, represents the most promising cuff-less BP
measurement principle. However, there are several critical barriers in exiting PTT measurements such as: (i)
subpar sensor sensitivity; (ii) poor sensor adhesion; (iii) difficulty in converting PTT measurements into BP
readings; (iv) difficult in obtaining both diastolic BP (DP) and systolic BP (SP) measurements. To address
these issues, the overall objective of this work is to combine arterial tonometry and PTT principles to achieve
cuff-less 24-hour ambulatory BP monitoring. This will be achieved by placing two wearable tonometric sensors
at arterial sites (proximal and distal) and collecting high-fidelity tonometric waveforms as well as PTT values.
Our innovations in this work include: (a) integrating ionic liquid and microstructures (which can accommodate
ions under pressure) in piezo-capacitive sensor to enhance both the sensitivity and dynamic range; (b)
incorporating micropillars (mimicking gecko’s feet) at the sensor substrate to promote adhesion and improve
the fidelity of captured waveforms; (c) calibrating tonometric waveforms with pre-constructed PTT-BP
relationships (via postural changes); (d) calibrating tonometric waveforms to extract both DP and SP
continuously by leveraging the similar shape of arterial tonometric and BP waveforms. The specific aims are:
(1) to develop wearable sensors to obtain high-fidelity tonometric waveforms; (2) to promote the adhesion of
wearable patches; (3) to develop PTT-based calibration for extracting both DP and SP; and (4) to validate the
system in human studies. Our expected outcome is an accurate, cuff-less, 24-hour BP monitoring system.
Successful completion of this project can lead to new clinical practices for ambulatory BP monitoring and post-
surgery hypotension surveillance.