COMBINED PET AND X RAY CT TOMOGRAPH FOR CLINICAL USE
COMBINED PET AND X RAY CT TOMOGRAPH FOR CLINICAL USE
批准号:
2443126
负责人:
DAVID W TOWNSEND
金额:
$17.95万
依托单位国家:
美国
项目类别:
财政年份:
1995
资助国家:
美国
项目状态:
已结题
起止时间:
1995-07-01 至 1999-06-30
中文摘要
点击翻译按钮获取中文摘要
英文摘要
The primary goal of this research proposal is to design, construct and
perform a limited validation of a new tomograph which has the capability
of operating either in X-ray CT or positron tomography (PET) mode. The
proposal is to mount an X-ray CT and two arrays of PET detectors on a
single support within the same gantry, and rotate the support to acquire
a full projection data set for both imaging modalities. The tomograph will
therefore acquire functional and anatomical images which are accurately
coregistered, without the use of external markers or internal landmarks.
A secondary objective is to use the CT data to improve the correction of
the PET data for attenuation and for contamination from scattered photons.
By using the CT image in a novel way, low-noise attenuation correction
factors for PET can be generated, and by integrating the anatomical
information from the CT into recently-developed scatter correction
methods, an accurate scatter correction can be obtained.
The use of 18F-fluorodeoxyglucose (FDG) is a rapidly growing application
area for PET, in which the increased glucose metabolism of neoplasms has
been used to determine the presence of recurrent glioma versus radiation
necrosis, recurrent colon carcinoma versus surgical scar and radiation
changes, and radiation necrosis versus reactive mediastinal lymph node. A
major difficulty in all these important applications of PET is the
accurate localization of the increased glucose uptake to a specific
anatomical structure. While multi-modality image alignment has been
extensively developed for the brain, little work has been done in the
thorax and abdomen owing to the technical difficulties of identifying
common structures and to the tendency for internal organs to move within
the body. In the proposed combined modality PET/CT tomograph, functional
and anatomical images are intrinsically co-registered. For this proposal,
a preliminary study of the capability of the new tomograph to detect and
localize tumors will be performed in a limited series of ten patients with
known malignant disease.
期刊论文(0)
专著(0)
科研奖励(0)
会议论文
A High Performance PET and CT Tomograph
-
批准号:6801114
-
项目类别:
-
资助金额:$97.7万
-
财政年份:2002
-
负责人:DAVID W TOWNSEND
-
依托单位:
A High Performance PET and CT Tomograph
-
批准号:6805220
-
项目类别:
-
资助金额:$73.88万
-
财政年份:2002
-
负责人:DAVID W TOWNSEND
-
依托单位:
A High Performance PET and CT Tomograph
-
批准号:6439104
-
项目类别:
-
资助金额:$28.98万
-
财政年份:2002
-
负责人:DAVID W TOWNSEND
-
依托单位:
A High Performance PET and CT Tomograph
-
批准号:6738134
-
项目类别:
-
资助金额:$61.63万
-
财政年份:2002
-
负责人:DAVID W TOWNSEND
-
依托单位:
INTERNATIONAL MEETING ON FULLY 3D IMAGE RECONSTRUCTION
-
批准号:2011734
-
项目类别:
-
资助金额:$1.7万
-
财政年份:1997
-
负责人:DAVID W TOWNSEND
-
依托单位:
METHODOLOGY FOR ONCOLOGY IMAGING WITH A PET/CT SCANNER
-
批准号:6376116
-
项目类别:
-
资助金额:$31.98万
-
财政年份:1995
-
负责人:DAVID W TOWNSEND
-
依托单位:
COMBINED PET AND X RAY CT TOMOGRAPH FOR CLINICAL USE
-
批准号:2109014
-
项目类别:
-
资助金额:$36.34万
-
财政年份:1995
-
负责人:DAVID W TOWNSEND
-
依托单位:
METHODOLOGY FOR ONCOLOGY IMAGING WITH A PET/CT SCANNER
-
批准号:6127856
-
项目类别:
-
资助金额:$25.82万
-
财政年份:1995
-
负责人:DAVID W TOWNSEND
-
依托单位:
METHODOLOGY FOR ONCOLOGY IMAGING WITH A PET/CT SCANNER
-
批准号:6512851
-
项目类别:
-
资助金额:$6.21万
-
财政年份:1995
-
负责人:DAVID W TOWNSEND
-
依托单位:
METHODOLOGY FOR ONCOLOGY IMAGING WITH A PET/CT SCANNER
-
批准号:6746592
-
项目类别:
-
资助金额:$26.01万
-
财政年份:1995
-
负责人:DAVID W TOWNSEND
-
依托单位:
COMBINED PET AND X RAY CT TOMOGRAPH FOR CLINICAL USE
-
批准号:2109013
-
项目类别:
-
资助金额:$38.15万
-
财政年份:1995
-
负责人:DAVID W TOWNSEND
-
依托单位: