PROSTHETICS FITTING SYSTEM
PROSTHETICS FITTING SYSTEM
批准号:
2673709
负责人:
MICHAEL W. VANNIER
金额:
$26.56万
依托单位:
依托单位国家:
美国
项目类别:
财政年份:
1992
资助国家:
美国
项目状态:
已结题
起止时间:
1992-09-30 至 2000-08-31
中文摘要
点击翻译按钮获取中文摘要
英文摘要
Lower extremity prosthesis fit results from a complex biomechanical
interaction at the interface between the residuum and socket. The quality
of fit determines subject comfort, acceptance, and potential for
ambulation. The long term goal of this research is comprehensive
assessment of lower limb prosthesis fit that is highly correlated with
subjective metrics and has high predictive value for complications and
functional outcome. In situ static 3D determination of prosthesis socket
fit by a valid, repeatable, practical, and comprehensive method is sought
to aid prosthesis design and evaluation, and to improve outcome.
Volumetric imaging based on x-ray spiral CT will be used for static in situ
lower limb prosthesis evaluation with and without axial loading. From
these image volume data sets, tissue composition volume fractions (fat,
muscle, bone, skin, other) will be extracted, mass properties estimated,
and shape information mapped onto a 3D display. Shape and fit will be
visualized by 3D. The measurement methods will be validated in vitro with
phantom test objects and cadaver parts, and in vivo with adult amputees.
Tissue composition estimates will be tested on extremity remnants phantoms,
and on cadaver limbs. Prediction of the biomechanical characteristics for
a given socket and limb remnant will be achieved by mathematical modeling.
Using the CT volume data, we will synthesize polynomial version (p-version)
finite element models that are static, fully 3--dimensional, incorporate
separate tissue compartment (bone, muscle/fascia, fat, skin, and
prosthesis), anisotropic, and nonlinear with large deformations. The
models will be validated experimentally and used to predict the quality of
socket fit.
Measurements using x-rat spiral CT imaging and finite element tools will be
used in a logistic regression model to determine the biomechanical
characteristics associated with good and poor fitting prostheses. The
feasibility of diagnostic fit evaluation using x-ray spiral CT and finite
element mapping methods will be determined through ROC and repeatability
analysis. Image-derived fit measures will be tested for correlation with
subjective reports corrected for covariation due to age, gender, race,
nutritional status, diabetes, smoking, amputation characteristics (stump
length, reason for amputation), and other factors known to influence fit.
On completion, this project will provide a valid and repeatable practical
comprehensive volumetric image-based method to aid lower limb prosthesis
design and evaluation. Prediction of the biomechanical characteristics of
a given socket and limb remnant by p-version finite element modeling will
be developed and tested.
期刊论文(10)
专著(0)
科研奖励(0)
会议论文
登录
查看更多内容
Finite element modeling and experimental verification of lower extremity shape change under load.
负载下下肢形状变化的有限元建模及实验验证。
DOI:
10.1016/s0021-9290(96)00179-0
发表时间:
1997
期刊:
Journal of biomechanics
影响因子:
2.4
作者:
[Commean,PK, Smith,KE, Vannier,MW, Szabo,BA, Actis,RL]
通讯作者:
Actis,RL
Validation of spiral CT and optical surface scanning for lower limb stump volumetry.
螺旋 CT 和光学表面扫描对下肢残肢体积测定的验证。
DOI:
10.3109/03093649509080351
发表时间:
1995
期刊:
Prosthetics and orthotics international
影响因子:
1.5
作者:
[Smith,KE, Commean,PK, Bhatia,G, Vannier,MW]
通讯作者:
Vannier,MW
Design of a 3-D surface scanner for lower limb prosthetics: a technical note.
下肢假肢 3D 表面扫描仪的设计:技术说明。
DOI:
--
发表时间:
1996
期刊:
Journal of rehabilitation research and development.
影响因子:
--
作者:
[Commean,PK, Smith,KE, Vannier,MW]
通讯作者:
Vannier,MW
A device for applying static loads to prosthetic limbs of transtibial amputees during spiral CT examination.
一种在螺旋CT检查期间对经胫骨截肢者的假肢施加静载荷的装置。
DOI:
--
发表时间:
2000
期刊:
Journal of rehabilitation research and development
影响因子:
--
作者:
[Madsen,MT, Haller,J, Commean,PK, Vannier,MW]
通讯作者:
Vannier,MW
NORMAL MR NEUROMORPHOMETRY BY GLOBAL PATTERN MATCHING
-
批准号:7420425
-
项目类别:
-
资助金额:$1.27万
-
财政年份:2006
-
负责人:MICHAEL W. VANNIER
-
依托单位:
NORMAL MR NEUROMORPHOMETRY BY GLOBAL PATTERN MATCHING
-
批准号:7182875
-
项目类别:
-
资助金额:$0.88万
-
财政年份:2005
-
负责人:MICHAEL W. VANNIER
-
依托单位:
NORMAL MR NEUROMORPHOMETRY BY GLOBAL PATTERN MATCHING
-
批准号:6972700
-
项目类别:
-
资助金额:$0.84万
-
财政年份:2004
-
负责人:MICHAEL W. VANNIER
-
依托单位:
NORMAL MR NEUROMORPHOMETRY BY GLOBAL PATTERN MATCHING
-
批准号:2379787
-
项目类别:
-
资助金额:$25.08万
-
财政年份:1996
-
负责人:MICHAEL W. VANNIER
-
依托单位:
NORMAL MR NEUROMORPHOMETRY BY GLOBAL PATTERN MATCHING
-
批准号:2669092
-
项目类别:
-
资助金额:$24.68万
-
财政年份:1996
-
负责人:MICHAEL W. VANNIER
-
依托单位:
NORMAL MR NEUROMORPHOMETRY BY GLOBAL PATTERN MATCHING
-
批准号:2883706
-
项目类别:
-
资助金额:$25.48万
-
财政年份:1996
-
负责人:MICHAEL W. VANNIER
-
依托单位:
NORMAL MR NEUROMORPHOMETRY BY GLOBAL PATTERN MATCHING
-
批准号:6165508
-
项目类别:
-
资助金额:$26.3万
-
财政年份:1996
-
负责人:MICHAEL W. VANNIER
-
依托单位:
NORMAL MR NEUROMORPHOMETRY BY GLOBAL PATTERN MATCHING
-
批准号:2274669
-
项目类别:
-
资助金额:$24.74万
-
财政年份:1996
-
负责人:MICHAEL W. VANNIER
-
依托单位:
PROSTHETICS FITTING SYSTEM
-
批准号:2638488
-
项目类别:
-
资助金额:$26.22万
-
财政年份:1992
-
负责人:MICHAEL W. VANNIER
-
依托单位:
PROSTHETICS FITTING SYSTEM
-
批准号:2202512
-
项目类别:
-
资助金额:$27.89万
-
财政年份:1992
-
负责人:MICHAEL W. VANNIER
-
依托单位:
PROSTHETICS FITTING SYSTEMS
-
批准号:3331516
-
项目类别:
-
资助金额:$28.17万
-
财政年份:1992
-
负责人:MICHAEL W. VANNIER
-
依托单位:
PROSTHETICS FITTING SYSTEM
-
批准号:2025435
-
项目类别:
-
资助金额:$20.25万
-
财政年份:1992
-
负责人:MICHAEL W. VANNIER
-
依托单位:
PROSTHETICS FITTING SYSTEM
-
批准号:2403294
-
项目类别:
-
资助金额:$7.44万
-
财政年份:1992
-
负责人:MICHAEL W. VANNIER
-
依托单位:
PROSTHETICS FITTING SYSTEMS
-
批准号:2202511
-
项目类别:
-
资助金额:$28.35万
-
财政年份:1992
-
负责人:MICHAEL W. VANNIER
-
依托单位:
DIAGNOSTIC IMAGING OF CRANIOSYNOSTOSES
-
批准号:3222724
-
项目类别:
-
资助金额:$16.2万
-
财政年份:1989
-
负责人:MICHAEL W. VANNIER
-
依托单位:
DIAGNOSTIC IMAGING OF CRANIOSYNOSTOSES
-
批准号:3222723
-
项目类别:
-
资助金额:$15.64万
-
财政年份:1989
-
负责人:MICHAEL W. VANNIER
-
依托单位:
DIAGNOSTIC IMAGING OF CRANIOSYNOSTOSES
-
批准号:3222722
-
项目类别:
-
资助金额:$22.05万
-
财政年份:1989
-
负责人:MICHAEL W. VANNIER
-
依托单位: