课题基金 / 基金详情

IMPLEMENTING CONE BEAM ALGORITHMS FOR CLINICAL SPECT

IMPLEMENTING CONE BEAM ALGORITHMS FOR CLINICAL SPECT
实施临床光谱锥束算法
批准号:
2750404
负责人:
G LAWRENCE ZENG
金额:
$10.42万
依托单位:
依托单位国家:
美国
项目类别:
财政年份:
1994
资助国家:
美国
项目状态:
已结题
起止时间:
1994-08-09 至 1999-07-31

项目摘要

项目成果

G LAWRENCE ZENG的其他基金

相关文献

中文摘要
翻译
点击翻译按钮获取中文摘要
英文摘要
Single-photon emission computed tomography (SPECT) has become an important diagnostic tool in nuclear medicine for imaging the heart, brain, liver, bones, and other organs because it is non-invasive and is less expensive than other modalities--for example, positron emission tomography (PET). The use of cone-beam collimators with SPECT has increased the sensitivity for imaging small organs like the brain and heart by taking advantage of the large field-of-view rotating gamma camera to magnify small organs onto a large detector area. The use of cone-beam collimators has demonstrated improved sensitivity and resolution over the use of parallel hole collimators, and has resulted in better detection and sizing of, for example, cardiac lesions with no increase in scanning time. However, with present SPECT systems, which have only single planar orbits, the application of cone-beam tomography to some structures shows slice-to- slice cross-talk. For organs like the brain this system shows image elongation along the axis of rotation near the top of the head in coronal and sagittal views due to insufficient data. To achieve sufficient data it is necessary for the scanning trajectory of the focal point to have at least one point of intersection for any plane passing through the reconstructed region of interest. This may require hardware modifications of present SPECT systems; however, even if sufficient data sampling is available, efficient analytical algorithms are not guaranteed. The proposed research will develop algorithms for reconstructing cone-beam projections with sufficient data sampling. Of special emphasis is the development of algorithms applicable to SPECT systems that can be modified with little or no additional cost to present clinical systems. The overall goal of the project is to develop efficient cone-beam reconstruction algorithms that provide artifact-free three-dimensional SPECT reconstructions for clinical use. The results will have the potential to significantly improve the diagnostic capability of nuclear medicine procedures. Upon completion of the project, software will be developed and tested. The research will develop engineering principles and guidelines for the design of SPECT systems that acquire sufficient data for cone-beam tomography and clinical protocols for acquiring and processing sufficient cone-beam data.
期刊论文(0)
专著(0)
科研奖励(0)
会议论文
Segmented-Parallel-Beam Stationary Cardiac SPECT
  • 批准号:
    8412762
  • 项目类别:
  • 资助金额:
    $33.51万
  • 财政年份:
    2012
  • 负责人:
    G LAWRENCE ZENG
  • 依托单位:
Segmented-Parallel-Beam Stationary Cardiac SPECT
  • 批准号:
    8237814
  • 项目类别:
  • 资助金额:
    $35.25万
  • 财政年份:
    2012
  • 负责人:
    G LAWRENCE ZENG
  • 依托单位:
Segmented-Parallel-Beam Stationary Cardiac SPECT
  • 批准号:
    8590221
  • 项目类别:
  • 资助金额:
    $34.44万
  • 财政年份:
    2012
  • 负责人:
    G LAWRENCE ZENG
  • 依托单位:
Small Animal SPECT Using a Skew-Slit Collimator
  • 批准号:
    7471761
  • 项目类别:
  • 资助金额:
    $18.78万
  • 财政年份:
    2008
  • 负责人:
    G LAWRENCE ZENG
  • 依托单位: