CT SYSTEM FOR THE STUDY OF BIOLOGICAL STRUCTURE
CT SYSTEM FOR THE STUDY OF BIOLOGICAL STRUCTURE
批准号:
2875946
负责人:
JOHN M BOONE
金额:
$10.74万
依托单位国家:
美国
项目类别:
财政年份:
1998
资助国家:
美国
项目状态:
已结题
起止时间:
1998-09-30 至 2000-08-31
中文摘要
本研究的总体目标是响应(PAR-97-074)“创新
英文摘要
The overall goal of this study, in response to (PAR-97-074) "Innovative
approaches to developing new technologies", is to develop the potential
of a small scale computed tomography (CT) for cross-sectional imaging
of small rodent models. The laboratory mouse and rat are key
participants in medical research in areas including carcinogenesis,
pharmaceutical development, cardiovascular disease, AIDS research,
device testing, and so on. The resolution of commercial CT scanners for
human imaging is on the order of 500 mum, and this resolution is too
poor to properly image the anatomy of a mouse or a rat, due to the small
physical dimensions of these animals. Consequently, to study changes
in these research animals, it often is necessary to sacrifice them and
perform direct anatomical visualization (e.g. thick section microscopy).
In many studies, cohorts of animals are subjected to some research
regiment, and then at various time points, some fraction of the cohort
is sacrificed and their anatomies are studied post mortem. The long
term objective of this technology-development proposal is to develop a
CT scanner specifically designed to produce high resolution (e.g. 50 to
100 mum pixels) cross-sectional images of suitably restrained and
anethesized small rodents, in vivo. The specific aims are to: (1) design
and build the CT hardware, (2) design, write and test the necessary
software to control the rotation and data acquisition, (3) using
theoretical and computer simulation methods, develop and optimize a CT
reconstruction algorithm tailored to the specific geometry of the small
scanner, and finally (4) to measure the imaging performance of the CT
scanner. Synchrotron sources have much greater fluence rates than x-ray
fluoroscopic systems, however they are not widely available and are too
expensive to be practical for this purpose. The proposed system will
make use of x-rays from a general purpose fluoroscopic system, and will
be specifically designed to adapt easily to most fluoroscopic x-ray
tubes, which are widely available in any medical center. A micro-CT
system is currently operational in the PI's laboratory, which employs
50 mum pixels and has a limiting spatial resolution of 10 cycles per mm.
This system produces excellent images of high contrast objects such as
the structure of bone, however is it fundamentally limited in its
ability to image soft tissue structure within an animal due to signal
to noise limitation. The SNR limitations are imposed by the limited x-
ray output of the fluoroscopic x-ray system used. In this proposal, we
hope to extend the performance of micro-CT systems by building a system
which is capable of using the much higher x-ray fluence rates which
exist closer to the x-ray focal spot. For example, by moving the
detector from its current location 51 cm from the source to 10 cm away,
the x-ray fluence rate can be increased 26 fold (inverse square law),
improving the theoretical SNR by a factor of 5 (SNR approximately DOSE
1/2). However, by moving the detector so close to the x-ray source,
it's physical size becomes a major detriment to achieving spatial
resolution. Techniques are proposed (multi-step deconvolution) to
compensate for this "focal spot blurring" in the image reconstruction
process. The focus of this proposal is to study various CT scanner
designs with specific attention to producing a practical solution to
imaging small animals; as such a system will have the potential for
broad impact on biomedical research. Furthermore, with the ability to
study anatomical changes within a single animal, the proposed scanner
will make it possible for researchers to substantially reduce the number
of animals used and simultaneously achieve higher statistical power,
since the bio-structure of individuals can be monitored serially over
time, the variation in response between individuals to the treatment
under study is eliminated.
期刊论文(0)
专著(0)
科研奖励(0)
会议论文
Breast CT: Final Steps to Translation
-
批准号:8830613
-
项目类别:
-
资助金额:$59.96万
-
财政年份:2015
-
负责人:JOHN M BOONE
-
依托单位:
Breast CT: Final Steps to Translation
-
批准号:9054809
-
项目类别:
-
资助金额:$57.57万
-
财政年份:2015
-
负责人:JOHN M BOONE
-
依托单位:
Breast CT: Final Steps to Translation
-
批准号:9266769
-
项目类别:
-
资助金额:$55.66万
-
财政年份:2015
-
负责人:JOHN M BOONE
-
依托单位:
Hybrid Nuclear/X-ray Projection System for Mouse Imaging
-
批准号:6951606
-
项目类别:
-
资助金额:$15.15万
-
财政年份:2004
-
负责人:JOHN M BOONE
-
依托单位:
Hybrid Nuclear/X-ray Projection System for Mouse Imaging
-
批准号:6848595
-
项目类别:
-
资助金额:$23.87万
-
财政年份:2004
-
负责人:JOHN M BOONE
-
依托单位:
Breast CT scanner for earlier cancer detection
-
批准号:7114357
-
项目类别:
-
资助金额:$85.35万
-
财政年份:2002
-
负责人:JOHN M BOONE
-
依托单位:
Breast CT scanner for earlier cancer detection
-
批准号:6933181
-
项目类别:
-
资助金额:$85.89万
-
财政年份:2002
-
负责人:JOHN M BOONE
-
依托单位:
Breast CT scanner for earlier cancer detection
-
批准号:8060548
-
项目类别:
-
资助金额:$105.69万
-
财政年份:2002
-
负责人:JOHN M BOONE
-
依托单位:
Breast CT scanner for earlier cancer detection
-
批准号:6789982
-
项目类别:
-
资助金额:$99.64万
-
财政年份:2002
-
负责人:JOHN M BOONE
-
依托单位:
Breast CT scanner for earlier cancer detection
-
批准号:7342661
-
项目类别:
-
资助金额:$109.37万
-
财政年份:2002
-
负责人:JOHN M BOONE
-
依托单位:
Breast CT scanner for earlier cancer detection
-
批准号:8269559
-
项目类别:
-
资助金额:$102.32万
-
财政年份:2002
-
负责人:JOHN M BOONE
-
依托单位:
Breast CT scanner for earlier cancer detection
-
批准号:7851080
-
项目类别:
-
资助金额:$111.7万
-
财政年份:2002
-
负责人:JOHN M BOONE
-
依托单位:
Breast CT scanner for earlier cancer detection
-
批准号:6651660
-
项目类别:
-
资助金额:$84.95万
-
财政年份:2002
-
负责人:JOHN M BOONE
-
依托单位:
Breast CT scanner for earlier cancer detection
-
批准号:7629642
-
项目类别:
-
资助金额:$112.77万
-
财政年份:2002
-
负责人:JOHN M BOONE
-
依托单位:
Breast CT scanner for earlier cancer detection
-
批准号:6424554
-
项目类别:
-
资助金额:$120.0万
-
财政年份:2002
-
负责人:JOHN M BOONE
-
依托单位:
Feasibility of CT in high risk breast cancer patients
-
批准号:6369934
-
项目类别:
-
资助金额:$23.93万
-
财政年份:2001
-
负责人:JOHN M BOONE
-
依托单位:
Feasibility of CT in high risk breast cancer patients
-
批准号:6647062
-
项目类别:
-
资助金额:$24.27万
-
财政年份:2001
-
负责人:JOHN M BOONE
-
依托单位:
Feasibility of CT in high risk breast cancer patients
-
批准号:6514833
-
项目类别:
-
资助金额:$24.23万
-
财政年份:2001
-
负责人:JOHN M BOONE
-
依托单位:
CT SYSTEM FOR THE STUDY OF BIOLOGICAL STRUCTURE
-
批准号:2896808
-
项目类别:
-
资助金额:$10.69万
-
财政年份:1998
-
负责人:JOHN M BOONE
-
依托单位:
EQUALIZED DUAL ENERGY/DUAL PHOSPHOR CHEST RADIOGRAPHY
-
批准号:3199907
-
项目类别:
-
资助金额:$14.7万
-
财政年份:1991
-
负责人:JOHN M BOONE
-
依托单位: