课题基金 / 基金详情

IN VIVO RADIONUCLIDE QUANTITATION USING EMISSION CT

IN VIVO RADIONUCLIDE QUANTITATION USING EMISSION CT
使用发射 CT 进行体内放射性核素定量
批准号:
3171392
负责人:
RONALD J JASZCZAK
金额:
$26.59万
依托单位:
依托单位国家:
美国
项目类别:
财政年份:
1983
资助国家:
美国
项目状态:
已结题
起止时间:
1983-03-01 至 1994-02-28

项目摘要

项目成果

RONALD J JASZCZAK的其他基金

相关文献

中文摘要
翻译
点击翻译按钮获取中文摘要
英文摘要
Quantitative single photon emission compute tomography (SPECT) has been limited mainly by the inadequate number of detected photons in the projections, attenuation within the body, the inclusion of scattered photons in the projections, and variations in collimator response with distance. The long term objectives of this project are: 1) to increase the number of detected photons by using new acquisition geometries, and 2) to develop and evaluate a unified reconstruction methodology for SPECT using a statistical Bayesian formulation. Cone beam collimation (CB) can result in a three-fold increase in the number of detected photons, compared with a parallel beam (PB) collimator having similar resolution characteristics. Bayesian image processing (BIP) can integrally include the a priori source distribution entropy information, the Poisson nature of the measured projection data, as well as other a priori information concerning the shift-variant point spread function. Filtered backprojection (FBP) is widely used since it offers the practical advantage of fast computational speed; however, BIP offers the potential for a more accurate reconstruction. Other statistical estimators, such as maximum likelihood (ML) and maximum entropy (MAXENT) are directly derivable from the Bayesian formulation. This project will evaluate cone beam SPECT using FBP and BIP approaches. A validated Monte Carlo model of the acquisition geometry will be used to determine the system response matrix. Receiver operator characteristic (ROC) curves will be used to evaluate lesion detectability for CB, fan beam (FB), and PB SPECT. The convergence characteristics of BIP will be quantitatively compared with ML and MAXENT, as a function of iteration number. Simulated and experimentally acquired projections of phantoms will be used to evaluate BIP for quantification of activity, activity ratios, resolution, and noise cone beam SPECT. Patient scans acquired with CB, FB, and parallel hole collimation will be compared. Early results indicate that cone beam collimation offers the potential for improved SPECT imaging. The application of a unified BIP algorithm that simultaneously compensates for attenuation, scatter, and collimator variations should offer further improvements in the accuracy of the reconstruction, and provide the basis for fundamental advances in SPECT quantification.
期刊论文(0)
专著(0)
科研奖励(0)
会议论文
Offset Astigmatic and Variable Focusing Collimation for Helical SPECT Brain Scans
  • 批准号:
    7406049
  • 项目类别:
  • 资助金额:
    $26.43万
  • 财政年份:
    2006
  • 负责人:
    RONALD J JASZCZAK
  • 依托单位:
Offset Astigmatic and Variable Focusing Collimation for Helical SPECT Brain Scans
  • 批准号:
    7216195
  • 项目类别:
  • 资助金额:
    $26.12万
  • 财政年份:
    2006
  • 负责人:
    RONALD J JASZCZAK
  • 依托单位:
Offset Astigmatic and Variable Focusing Collimation for Helical SPECT Brain Scans
  • 批准号:
    7078929
  • 项目类别:
  • 资助金额:
    $24.47万
  • 财政年份:
    2006
  • 负责人:
    RONALD J JASZCZAK
  • 依托单位:
Update of Duke Research SPECT System
  • 批准号:
    6440935
  • 项目类别:
  • 资助金额:
    $48.5万
  • 财政年份:
    2002
  • 负责人:
    RONALD J JASZCZAK
  • 依托单位: