EFFECTS OF MICROPHONE PLACEMENT ON DOSIMETRY MONITORING OF INDUSTRIAL NOISE
EFFECTS OF MICROPHONE PLACEMENT ON DOSIMETRY MONITORING OF INDUSTRIAL NOISE
批准号:
3753172
负责人:
L SHORTLAND
金额:
$0.0万
依托单位国家:
美国
项目类别:
财政年份:
--
资助国家:
美国
项目状态:
未结题
起止时间:
至
中文摘要
本项目检验了麦克风位置影响声音的假设
英文摘要
This project tested the hypothesis that microphone site influences the
individual noise exposure experienced by workers exposed to industrial
noise. It also examined inter-individual differences in outer ear
pressure gain.
The following sequential 20 minute measures were taken with three
microphone placements: probe tube microphone in the ear canal; on the
right shoulder; attached to the left breast pocket. The subjects were
instructed to follow their normal work routines during noise monitoring.
Data were downloaded to a personal computer and statistically analyzed
for differences between treatment levels and between subject variability.
The study was conducted with the cooperation of the Division of Safety
at the NIH air conditioning chiller plant using NIH employees. Six adult
subjects were monitored. Sound field-to-eardrum pressure gain measures
taken from an additional subject and existing data from 29 subjects
enrolled in another protocol were used to construct norms.
Results showed higher sound pressure levels when recorded at the eardrum
vs. the shoulder and chest (p<.001). Large between subject variability
was observed for eardrum measurements only. Sound field-to-eardrum
pressure gains showed a normal distribution, from which parametric
statistics were calculated. ISO 1999 "Acoustics - Determination of
occupational noise exposure and estimation of noise-induced hearing
impairment" is an international standard which attempts to predict
hearing loss based partly on exposure level. The values are taken from
a large population mean using traditional measurement protocols, i.e.,
torso microphone placement. The norms established in this study were for
application to ISO 1999 in order to allow a comparison of an individual's
exposure level to the ISO data.
期刊论文(0)
专著(0)
科研奖励(0)
会议论文
EFFECTS OF MICROPHONE PLACEMENT ON DOSIMETRY MONITORING OF INDUSTRIAL NOISE
-
批准号:3775260
-
项目类别:
-
资助金额:$0.0万
-
财政年份:--
-
负责人:L SHORTLAND
-
依托单位: