中文摘要
描述(改编自申请人摘要):筛查乳房x线摄影具有
英文摘要
DESCRIPTION (Adapted from Applicant's Abstract): Screening mammography has
proven to be an effective procedure for the detection of early breast cancer.
However, a significant fraction of cancer escapes detection due to dense
glandular tissue which obscures the underlying pathology. Diffraction Enhanced
x-ray Imaging (DEI) has the potential to dramatically change mammography and
radiography in general. Specifically developed as part of an x-ray mammography
program utilizing monochromatic x-rays from a synchrotron source, this
technique has produced images of test objects and issue whose contrast and
information content far exceeds conventional techniques. Preliminary work with
human breast cancer specimens suggests that DEI images include information
regarding specific physical characteristics of the lesion including border
detail and associated features that are not detected by conventional imaging.
The long term goal of this program is to develop a clinical based DEI system
for mammography. The first phase of this program is to identify the optimal DEI
parameters for improved visualization of lesions of the breast and to use these
parameters to develop a conceptual design of a clinical DEI system. The
synchrotron provides the ideal environment to perform these pilot studies since
it provides a very intense, collimated, and tunable source of x-radiation.
Specifically, a study of human breast tissue samples with cancer will be
performed in which the DEI parameters will be systematically assessed regarding
the visibility of structures suggestive of breast cancer-namely, spiculation
architectural distortion, and calcification. This study will include the
assessment of a wide variety of DEI parameters including imaging energy,
refraction/scatter-rejection sensitivity, location on the "rocking curve," and
x-ray optical geometry. The intent of this study is to optimize DEI for the
clinical task. This will allow us to specify the x-ray source, x-ray optics,
and detection method requirements for a clinical based system. As a result of
this work the applicants propose to develop a conceptual design for a clinical
system for mammography using DEI.