aSi/CsI FP digital chest imaging with scatter rejection
aSi/CsI FP digital chest imaging with scatter rejection
批准号:
6876121
负责人:
CHRIS C SHAW
金额:
$54.54万
依托单位国家:
美国
项目类别:
财政年份:
2002
资助国家:
美国
项目状态:
已结题
起止时间:
2002-06-01 至 2008-03-31
中文摘要
点击翻译按钮获取中文摘要
英文摘要
Despite improved DQEs of recently commercialized flat- panel detectors, two problems intrinsic to projection x-ray imaging with area detectors remain and degrade the low contrast performance: (1) low photon fluences at the detector in heavily attenuated regions, and (2) lack of efficient methods to reject scattered radiation. The expectation that these problems would be resolved or become less important through improved DQEs is somewhat illusive. One major benefit with digital detectors is the prospect of digital image processing and analysis. However, this benefit is hard to realize due to the low signal-to-noise ratios in heavily attenuated regions where image processing often finds most use. To resolve the above mentioned problems, we propose to construct and investigate a scanning equalization digital radiography (SEDR) system using an aSi:H and CsI:Tl based flat-panel detector. Slit scanning imaging with regionally adjustable beam width will be used to achieve effective scatter rejection and exposure equalization. A pre-exposure image will be used to compute the necessary beam width modulations for the scan, eliminating the need for using a radiation detector array. A novel image readout scheme will be used to provide electronic aft-collimation to achieve scatter rejection without attenuating primary x-rays and without using a heavy, bulky aft-collimator. A re-scaling technique will be implemented to convert equalized digital chest images into images with the appearance of conventional chest images but with enhanced contrast and equalized SNRs. To evaluate the proposed technique, we will measure and characterize the performance of the proposed SEDR system. We will study and demonstrate image quality improvements with phantom images. We will also conduct a comprehensive 350 patient ROC study to compare the scanning equalization DR chest images with regular DR images with and without digital image enhancement processing. The proposed system is expected to improve the low contrast performance of digital chest images by: (1) more effectively rejecting scattered radiation without attenuating primary x-rays, (2) increasing x-ray fluences in heavily attenuated regions to improve SNRs and reduce impact of scattered radiation there, (3) providing high quality image data with improved contrast-to-noise ratios and equalized SNRs for further digital image processing and analysis without suffering excessive noise limitations in heavily attenuated regions.
期刊论文(22)
专著(0)
科研奖励(0)
会议论文
登录
查看更多内容
Effects of exposure equalization on image signal-to-noise ratios in digital mammography: a simulation study with an anthropomorphic breast phantom.
曝光均衡对数字乳房X线摄影中图像信噪比的影响:拟人化乳房模型的模拟研究。
DOI:
10.1118/1.3659709
发表时间:
2011
期刊:
Medical physics
影响因子:
3.8
作者:
[Liu,Xinming, Lai,Chao-Jen, Whitman,GaryJ, Geiser,WilliamR, Shen,Youtao, Yi,Ying, Shaw,ChrisC]
通讯作者:
Shaw,ChrisC
Comparison of two detector systems for cone beam CT small animal imaging - a preliminary study.
两种锥束 CT 小动物成像探测器系统的比较 - 初步研究。
DOI:
10.1117/12.656690
发表时间:
2006
期刊:
Proceedings of SPIE--the International Society for Optical Engineering
影响因子:
--
作者:
[Meng,Yang, Shaw,ChrisC, Liu,Xinming, Altunbas,MustafaC, Wang,Tianpeng, Chen,Lingyun, Tu,Shu-Ju, Kappadath,SCheenu, Lai,Chao-Jen]
通讯作者:
Lai,Chao-Jen
Radiation doses in volume-of-interest breast computed tomography--A Monte Carlo simulation study.
感兴趣体积乳腺计算机断层扫描中的辐射剂量——蒙特卡罗模拟研究。
DOI:
10.1118/1.4921069
发表时间:
2015
期刊:
Medical physics
影响因子:
3.8
作者:
[Lai,Chao-Jen, Zhong,Yuncheng, Yi,Ying, Wang,Tianpeng, Shaw,ChrisC]
通讯作者:
Shaw,ChrisC
DOI:
10.1088/0031-9155/54/21/016
发表时间:
2009-11-07
期刊:
Physics in medicine and biology
影响因子:
3.5
作者:
[Lai CJ, Chen L, Zhang H, Liu X, Zhong Y, Shen Y, Han T, Ge S, Yi Y, Wang T, Yang WT, Whitman GJ, Shaw CC]
通讯作者:
Shaw CC
Noise simulation in cone beam CT imaging with parallel computing.
并行计算的锥束 CT 成像噪声模拟。
DOI:
10.1088/0031-9155/51/5/017
发表时间:
2006
期刊:
Physics in medicine and biology
影响因子:
3.5
作者:
[Tu,Shu-Ju, Shaw,ChrisC, Chen,Lingyun]
通讯作者:
Chen,Lingyun
共 10 条
DTS Imaging with a Digitally Addressable X-Ray Source (DAXS)
-
批准号:8454505
-
项目类别:
-
资助金额:$51.17万
-
财政年份:2010
-
负责人:CHRIS C SHAW
-
依托单位:
DTS Imaging with a Digitally Addressable X-Ray Source (DAXS)
-
批准号:8232075
-
项目类别:
-
资助金额:$55.14万
-
财政年份:2010
-
负责人:CHRIS C SHAW
-
依托单位:
DTS Imaging with a Digitally Addressable X-Ray Source (DAXS)
-
批准号:8067873
-
项目类别:
-
资助金额:$55.86万
-
财政年份:2010
-
负责人:CHRIS C SHAW
-
依托单位:
DTS Imaging with a Digitally Addressable X-Ray Source (DAXS)
-
批准号:8616346
-
项目类别:
-
资助金额:$52.13万
-
财政年份:2010
-
负责人:CHRIS C SHAW
-
依托单位:
DTS Imaging with a Digitally Addressable X-Ray Source (DAXS)
-
批准号:7890255
-
项目类别:
-
资助金额:$52.65万
-
财政年份:2010
-
负责人:CHRIS C SHAW
-
依托单位:
A Dual Resolution Cone Beam CT System for 3-D Breast Imaging
-
批准号:7905025
-
项目类别:
-
资助金额:$44.1万
-
财政年份:2007
-
负责人:CHRIS C SHAW
-
依托单位:
A Dual Resolution Cone Beam CT System for 3-D Breast Imaging
-
批准号:7315363
-
项目类别:
-
资助金额:$23.4万
-
财政年份:2007
-
负责人:CHRIS C SHAW
-
依托单位:
A Dual Resolution Cone Beam CT System for 3-D Breast Imaging
-
批准号:7689485
-
项目类别:
-
资助金额:$45.02万
-
财政年份:2007
-
负责人:CHRIS C SHAW
-
依托单位:
A Dual Resolution Cone Beam CT System for 3-D Breast Imaging
-
批准号:7690341
-
项目类别:
-
资助金额:$44.2万
-
财政年份:2007
-
负责人:CHRIS C SHAW
-
依托单位:
Optimized Digital Mammography with an a-Se FP Imager
-
批准号:7240452
-
项目类别:
-
资助金额:$58.57万
-
财政年份:2004
-
负责人:CHRIS C SHAW
-
依托单位:
Optimized Digital Mammography with an a-Se FP Imager
-
批准号:7070067
-
项目类别:
-
资助金额:$54.8万
-
财政年份:2004
-
负责人:CHRIS C SHAW
-
依托单位:
Optimized Digital Mammography with an a-Se FP Imager
-
批准号:6709265
-
项目类别:
-
资助金额:$53.88万
-
财政年份:2004
-
负责人:CHRIS C SHAW
-
依托单位:
Optimized Digital Mammography with an a-Se FP Imager
-
批准号:6890899
-
项目类别:
-
资助金额:$54.98万
-
财政年份:2004
-
负责人:CHRIS C SHAW
-
依托单位:
aSi/CsI FP digital chest imaging with scatter rejection
-
批准号:6467624
-
项目类别:
-
资助金额:$68.75万
-
财政年份:2002
-
负责人:CHRIS C SHAW
-
依托单位:
aSi/CsI FP digital chest imaging with scatter rejection
-
批准号:6623554
-
项目类别:
-
资助金额:$47.62万
-
财政年份:2002
-
负责人:CHRIS C SHAW
-
依托单位:
aSi/CsI FP digital chest imaging with scatter rejection
-
批准号:6721499
-
项目类别:
-
资助金额:$55.31万
-
财政年份:2002
-
负责人:CHRIS C SHAW
-
依托单位:
ASYMMETRIC DUAL SCREEN CR CHEST IMAGING
-
批准号:2906622
-
项目类别:
-
资助金额:$21.0万
-
财政年份:1999
-
负责人:CHRIS C SHAW
-
依托单位:
DIGITAL ACQUISITION AND DISPLAY OF MAMMOGRAMS
-
批准号:2094220
-
项目类别:
-
资助金额:$17.47万
-
财政年份:1990
-
负责人:CHRIS C SHAW
-
依托单位:
ASYMMETRIC DUAL SCREEN CR CHEST IMAGING
-
批准号:6164063
-
项目类别:
-
资助金额:$24.64万
-
财政年份:1990
-
负责人:CHRIS C SHAW
-
依托单位:
ASYMMETRIC DUAL SCREEN CR CHEST IMAGING
-
批准号:2882366
-
项目类别:
-
资助金额:$23.94万
-
财政年份:1990
-
负责人:CHRIS C SHAW
-
依托单位: