课题基金 / 基金详情

ASYMMETRIC DUAL SCREEN CR CHEST IMAGING

ASYMMETRIC DUAL SCREEN CR CHEST IMAGING
不对称双屏 CR 胸部成像
批准号:
6164063
负责人:
CHRIS C SHAW
金额:
$24.64万
依托单位国家:
美国
项目类别:
财政年份:
1990
资助国家:
美国
项目状态:
已结题
起止时间:
1990-07-01 至 2003-02-28

项目摘要

项目成果

CHRIS C SHAW的其他基金

相关文献

中文摘要
翻译
点击翻译按钮获取中文摘要
英文摘要
DESCRIPTION (Adapted from Applicant's Abstract): Despite new advances in medical imaging, projection radiography continues to be an important tool for detection of pulmonary diseases including lung cancer, interstitial lung diseases, as well as a variety of other thoracic diseases. Conventional chest radiography techniques rely on the use of a screen-film combination as the image receptor. Various digital radiography techniques have been developed and investigated to improve the quality, display, processing, utilization and management of radiographic images. Among them, computed radiography (CR) has become a promising candidate for large scale implementation of digital radiography and integration with a Picture Archival and Communication System (PACS) and has found wide use in bedside chest imaging in intensive care units (ICUs). However, current CR systems, due to its single screen design, have intrinsically lower detection quantum efficiency (DQE) and spatial resolution than the conventional screen film techniques. Partially for these reasons, they have not replaced screen-film techniques in chest radiography for primary diagnosis of pulmonary diseases. In this project, the applicants proposed to use a high resolution (HR) screen and a standard resolution (ST) screen to simultaneously acquire a high resolution front image and a standard resolution, low noise back image. These two images are superimposed to construct an image of improved DQE and spatial resolution. This technique referred to as the asymmetric dual-screen CR technique, will be optimized and tested using an experimental CR imaging system. Image properties of the optimized dual-screen CR images will be characterized by measuring the signal response, MTF, and noise properties. A comprehensive patient study will be conducted to evaluate and compare the duel-screen CR techniques with the single-screen CR and conventional screen-film techniques. Success of this project could result in a CR technique with a spatial resolution and DQE comparable to or even superior than those of the conventional screen-film techniques. The asymmetric dual-screen CR technique should help upgrade the quality of CR chest images substantially and lead to improved accuracy for primary diagnosis of pulmonary diseases.
期刊论文(19)
专著(0)
科研奖励(0)
会议论文
Comparison of three tissue composition measurement techniques using digital mammograms--a signal-to-noise study.
使用数字乳房X光检查的三种组织成分测量技术的比较——一项信噪比研究。
DOI: 10.1007/bf03168737
发表时间: 1998
期刊: Journal of digital imaging
影响因子: 4.4
作者: [Breitenstein,DS, Shaw,CC]
通讯作者: Shaw,CC
Comparison of three different techniques for dual-energy subtraction imaging in digital radiography: a signal-to-noise analysis.
数字放射线照相中双能量减影成像三种不同技术的比较:信噪比分析。
DOI: 10.1007/bf03167808
发表时间: 1992
期刊: Journal of digital imaging
影响因子: 4.4
作者: [Shaw,CC, Gur,D]
通讯作者: Gur,D
Use of meta-analysis in the evaluation of imaging systems.
在成像系统评估中使用荟萃分析。
DOI: 10.1016/s1076-6332(05)80788-3
发表时间: 1994
期刊: Academic radiology
影响因子: 4.8
作者: [Rockette,HE, Gur,D, Campbell,WL, Thaete,FL]
通讯作者: Thaete,FL
On the validity of the continuous and discrete confidence rating scales in receiver operating characteristic studies.
关于接受者操作特征研究中连续和离散置信度量表的有效性。
DOI: 10.1097/00004424-199310000-00019
发表时间: 1993
期刊: Investigative radiology
影响因子: 6.7
作者: [King,JL, Britton,CA, Gur,D, Rockette,HE, Davis,PL]
通讯作者: Davis,PL
12
    DTS Imaging with a Digitally Addressable X-Ray Source (DAXS)
    DTS Imaging with a Digitally Addressable X-Ray Source (DAXS)
    DTS Imaging with a Digitally Addressable X-Ray Source (DAXS)
    DTS Imaging with a Digitally Addressable X-Ray Source (DAXS)