中文摘要
点击翻译按钮获取中文摘要
英文摘要
DESCRIPTION (provided by applicant): The goal of newborn hearing screening is to identity infants with inner ear pathology (IEP), but most neonates who fail screening have conductive disorders (CD) rather than IEP, resulting in high false positive rates and costly follow-up diagnostic evaluation. The Rhode Island study (1993) has shown that the prevalence of conductive disorders (CD) over inner ear pathologies (IEP) to be 17 vs. 3-to-6 per 1000. While in N1CU the prevalence of CD over IEP rises to 36 vs. 23 per 1000. The ramifications of IEP and CD are different, so an accurate typing of the loss at the time of a newborn hearing screening is essential. The main objective of this proposal is to build a hearing-screening device that combines wideband reflectance measurement with DPOAE measurement into one system, where the former provides diagnostic evaluation for CD and the latter provides diagnostic evaluation for the IEP Thus in one test; both the conductive path and cochlear status are evaluated. Since both the reflectance measurement and the DPOAE measurement require an identical calibration step, the extra time needed to perform hearing screening, using the combined screening device, will be no more than few minutes. The benefit of the expected outcome is reduced false-positive rates, reduces follow up diagnostic costs, and reduced parental concern in the case of false positives.
An important auxiliary benefit of the probe impedance, obtained by the reflectance measurement, is to allow for a direct estimate of the signal intensity level in the ear canal so as to mitigate the standing wave problem in the audiometric measurement. In conjunction with DPOAE measurement, the WR-DP screener will provide more accurate measurement above 3 kHz where standing wave problem occurs.
The specific aims of Phase II are (1) to complete the development of the wideband reflectance-distortion product otoacoustic emission (WR-DP) screening device, toward improving its efficiency, reliability and ease of use; (2) to perform clinical studies, to obtain baseline data for the WR-DP screener, and (3) to demonstrate the diagnostic capabilities and cost effectiveness of the WR-DP screener.
期刊论文(0)
专著(0)
科研奖励(0)
会议论文
Development of a power-based (intensity-based) audiometer to improve hearing thre
-
批准号:7539734
-
项目类别:
-
资助金额:$15.64万
-
财政年份:2008
-
负责人:PATRICIA S JENG
-
依托单位:
Non-Invasive Instrument for Monitoring Changes in Intracranial Pressure
-
批准号:7223771
-
项目类别:
-
资助金额:$18.2万
-
财政年份:2007
-
负责人:PATRICIA S JENG
-
依托单位:
A Wide-band Reflectance - DPOAE (WR-DP)Screener
-
批准号:6736192
-
项目类别:
-
资助金额:$20.09万
-
财政年份:2004
-
负责人:PATRICIA S JENG
-
依托单位:
A Wide Band Reflectance - DPOAE (WR-DP) Screener
-
批准号:7001269
-
项目类别:
-
资助金额:$61.0万
-
财政年份:2004
-
负责人:PATRICIA S JENG
-
依托单位:
ACOUSTICAL POWER FLOW AS AN AUDIOLOGICAL TOOL
-
批准号:2128625
-
项目类别:
-
资助金额:$9.9万
-
财政年份:1996
-
负责人:PATRICIA S JENG
-
依托单位:
ACOUSTICAL POWER FLOW AS AN AUDIOLOGICAL TOOL
-
批准号:6499974
-
项目类别:
-
资助金额:$5.1万
-
财政年份:1996
-
负责人:PATRICIA S JENG
-
依托单位:
ACOUSTICAL POWER FLOW AS AN AUDIOLOGICAL TOOL
-
批准号:6175405
-
项目类别:
-
资助金额:$46.86万
-
财政年份:1996
-
负责人:PATRICIA S JENG
-
依托单位:
ACOUSTICAL POWER FLOW AS AN AUDIOLOGICAL TOOL
-
批准号:2801447
-
项目类别:
-
资助金额:$50.66万
-
财政年份:1996
-
负责人:PATRICIA S JENG
-
依托单位: