Advanced IVUS Imaging with MUTs
使用 MUT 进行高级 IVUS 成像
基本信息
- 批准号:7018367
- 负责人:
- 金额:$ 48.08万
- 依托单位:
- 依托单位国家:美国
- 项目类别:
- 财政年份:2006
- 资助国家:美国
- 起止时间:2006-06-01 至 2009-05-31
- 项目状态:已结题
- 来源:
- 关键词:angiocardioultrasonographyaortaatherosclerosisatherosclerotic plaquebioengineering /biomedical engineeringbioimaging /biomedical imagingbiomedical equipment developmentcardiovascular disorder diagnosiscardiovascular imaging /visualizationclinical biomedical equipmentcoronary arterydisease /disorder modelheart catheterizationlaboratory rabbitmicroelectrodesmicroprocessor /microchipminiature biomedical equipmentsilicontechnology /technique development
项目摘要
DESCRIPTION (provided by applicant): Intravascular ultrasound (IVUS) imaging has become an essential imaging modality for the effective diagnosis and treatment of cardiovascular diseases during the past decade due to innovative applications of piezoelectric transducer technology. The limitations of the same piezoelectric transducers have impeded the improvement of IVUS for emerging clinically important applications such as forward viewing arrays for guiding interventions, high resolution imaging of arterial structure such as vulnerable plaque, vasa vasorum and fibrous cap, and for implementation of techniques such as harmonic imaging of the arterial tissue and of the contrast agents. In this project, we plan to proceed on two parallel paths with immediate and long term impact. On one path we propose to develop low cost, low profile, broadband CMUT-based IVUS probes with 2 to 4 single chip annular arrays to generate M-mode slices of coronary arteries around 25MHz center frequency and 100% fractional bandwidth. These arrays will improve the crossing capabilities of IVUS catheters and can be potentially scanned and pulled back manually to generate images during interventions. Implementation and testing of these probes will enhance our understanding of issues related to the manufacturing of CMUT-based IVUS arrays and result in possible design improvements. In parallel with this effort, the second path aims to explore innovations in CMUT design to enable novel IVUS applications. CMUTs with dual electrode structures not only improve the pressure output for high penetration depth and tissue harmonic generation, but these transducers may simplify the probe electronics by removing the need for transmit-receive switching. Dual electrode CMUT structure coupled with mass loaded CMUT membranes opens up other possibilities. With enhanced sensitivity to selected harmonics based on these novel CMUTs, the proposed research may advance medical ultrasound imaging in general generating an impact much broader than IVUS.
描述(由申请人提供):由于压电换能器技术的创新应用,血管内超声(IVUS)成像在过去十年中已成为有效诊断和治疗心血管疾病的基本成像模式。相同的压电换能器的局限性阻碍了IVUS用于新兴的临床重要应用的改进,例如用于引导介入的前向观察阵列、动脉结构(例如易损斑块、血管和纤维帽)的高分辨率成像,以及用于实现诸如动脉组织和造影剂的谐波成像的技术。在这个项目中,我们计划在两条并行的道路上进行,具有直接和长期的影响。在一条路径上,我们建议开发低成本、低剖面、宽带基于CMUT的IVUS探头,其具有2至4个单片环形阵列,以在25 MHz中心频率和100%部分带宽附近生成冠状动脉的M模式切片。这些阵列将提高IVUS导管的通过能力,并且可以在干预期间手动扫描和拉回以生成图像。这些探头的实施和测试将增强我们对基于CMUT的IVUS阵列制造相关问题的理解,并导致可能的设计改进。与此同时,第二条道路旨在探索CMUT设计的创新,以实现新颖的IVUS应用。具有双电极结构的CMUT不仅提高了高穿透深度和组织谐波产生的压力输出,而且这些换能器可以通过消除对发射-接收切换的需要来简化探头电子器件。与质量加载CMUT膜耦合的双电极CMUT结构开辟了其他可能性。通过增强对基于这些新型CMUT的选定谐波的灵敏度,拟议的研究可能会在总体上推进医学超声成像,产生比IVUS更广泛的影响。
项目成果
期刊论文数量(0)
专著数量(0)
科研奖励数量(0)
会议论文数量(0)
专利数量(3)
数据更新时间:{{ journalArticles.updateTime }}
{{
item.title }}
{{ item.translation_title }}
- DOI:
{{ item.doi }} - 发表时间:
{{ item.publish_year }} - 期刊:
- 影响因子:{{ item.factor }}
- 作者:
{{ item.authors }} - 通讯作者:
{{ item.author }}
数据更新时间:{{ journalArticles.updateTime }}
{{ item.title }}
- 作者:
{{ item.author }}
数据更新时间:{{ monograph.updateTime }}
{{ item.title }}
- 作者:
{{ item.author }}
数据更新时间:{{ sciAawards.updateTime }}
{{ item.title }}
- 作者:
{{ item.author }}
数据更新时间:{{ conferencePapers.updateTime }}
{{ item.title }}
- 作者:
{{ item.author }}
数据更新时间:{{ patent.updateTime }}
F. Levent Degertekin其他文献
Dynamically reconfigurable acoustofluidic metasurface for subwavelength particle manipulation and assembly
用于亚波长粒子操纵和组装的动态可重构声流体超表面
- DOI:
10.1038/s41467-024-55337-0 - 发表时间:
2025-01-15 - 期刊:
- 影响因子:15.700
- 作者:
Sushruta Surappa;Suraj Pavagada;Fernando Soto;Demir Akin;Charles Wei;F. Levent Degertekin;Utkan Demirci - 通讯作者:
Utkan Demirci
IVUS beyond the horizon.
IVUS 超出地平线。
- DOI:
10.4244/eijv2i1a23 - 发表时间:
2006 - 期刊:
- 影响因子:0
- 作者:
A. V. D. van der Steen;R. Baldewsing;F. Levent Degertekin;S. Emelianov;M. Frijlink;Yuji Furukawa;David E. Goertz;Mustafa Karaman;P. Khuri;Kang Kim;F. Mastik;T. Moriya;O. Oralkan;Y. Saijo;J. Schaar;P. Serruys;S. Sethuraman;A. Tanaka;H. Vos;Russell S Witte;Matthew O’Donnell - 通讯作者:
Matthew O’Donnell
Controlling tip-sample interaction forces during a single tap for improved topography and mechanical property imaging of soft materials by AFM.
在单次敲击过程中控制尖端与样品的相互作用力,以改善 AFM 对软材料的形貌和机械性能成像。
- DOI:
10.1016/j.ultramic.2009.04.006 - 发表时间:
2009 - 期刊:
- 影响因子:2.2
- 作者:
Z. Parlak;R. Hadizadeh;M. Balantekin;F. Levent Degertekin - 通讯作者:
F. Levent Degertekin
F. Levent Degertekin的其他文献
{{
item.title }}
{{ item.translation_title }}
- DOI:
{{ item.doi }} - 发表时间:
{{ item.publish_year }} - 期刊:
- 影响因子:{{ item.factor }}
- 作者:
{{ item.authors }} - 通讯作者:
{{ item.author }}
{{ truncateString('F. Levent Degertekin', 18)}}的其他基金
Acousto-optical RF field sensors for safer diagnostic and interventional MRI
用于更安全的诊断和介入 MRI 的声光射频场传感器
- 批准号:
10526413 - 财政年份:2020
- 资助金额:
$ 48.08万 - 项目类别:
Acousto-optical RF field sensors for safer diagnostic and interventional MRI
用于更安全的诊断和介入 MRI 的声光射频场传感器
- 批准号:
10300995 - 财政年份:2020
- 资助金额:
$ 48.08万 - 项目类别:
Acousto-optical RF field sensors for safer diagnostic and interventional MRI
用于更安全的诊断和介入 MRI 的声光射频场传感器
- 批准号:
9917421 - 财政年份:2020
- 资助金额:
$ 48.08万 - 项目类别:
Acousto-optical RF field sensors for safer diagnostic and interventional MRI
用于更安全的诊断和介入 MRI 的声光射频场传感器
- 批准号:
10093044 - 财政年份:2020
- 资助金额:
$ 48.08万 - 项目类别:
Intravascular Ultrasound Imaging Guidewire with Wireless Readout
具有无线读数功能的血管内超声成像导丝
- 批准号:
8702711 - 财政年份:2014
- 资助金额:
$ 48.08万 - 项目类别:
Safe Ultrasonic Transmission Lines for MRI Catheters
用于 MRI 导管的安全超声波传输线
- 批准号:
8879142 - 财政年份:2014
- 资助金额:
$ 48.08万 - 项目类别:
MRI-safe 3Dl intracardiac ultrasound catheter for cardiovascular intervention
用于心血管介入的 MRI 安全 3Dl 心内超声导管
- 批准号:
8639877 - 财政年份:2014
- 资助金额:
$ 48.08万 - 项目类别:
Safe Ultrasonic Transmission Lines for MRI Catheters
用于 MRI 导管的安全超声波传输线
- 批准号:
8772802 - 财政年份:2014
- 资助金额:
$ 48.08万 - 项目类别:
Gap Feedback Linearization of CMUTs for Harmonic Imaging and HIFU
用于谐波成像和 HIFU 的 CMUT 间隙反馈线性化
- 批准号:
8656105 - 财政年份:2013
- 资助金额:
$ 48.08万 - 项目类别:
Gap Feedback Linearization of CMUTs for Harmonic Imaging and HIFU
用于谐波成像和 HIFU 的 CMUT 间隙反馈线性化
- 批准号:
8512365 - 财政年份:2013
- 资助金额:
$ 48.08万 - 项目类别:
相似海外基金
B VITAMIN ATHEROSCLEROSIS INTERVENTION TRAIL
B 族维生素动脉粥样硬化干预试验
- 批准号:
6533829 - 财政年份:2000
- 资助金额:
$ 48.08万 - 项目类别:
B VITAMIN ATHEROSCLEROSIS INTERVENTION TRAIL
B 族维生素动脉粥样硬化干预试验
- 批准号:
6372391 - 财政年份:2000
- 资助金额:
$ 48.08万 - 项目类别:
B VITAMIN ATHEROSCLEROSIS INTERVENTION TRAIL
B 族维生素动脉粥样硬化干预试验
- 批准号:
6767743 - 财政年份:2000
- 资助金额:
$ 48.08万 - 项目类别:
B VITAMIN ATHEROSCLEROSIS INTERVENTION TRAIL
B 族维生素动脉粥样硬化干预试验
- 批准号:
6644733 - 财政年份:2000
- 资助金额:
$ 48.08万 - 项目类别:
SUPPLEMENT B-Vitamin Atherosclerosis Intervention Trial
补充 B 族维生素动脉粥样硬化干预试验
- 批准号:
6383086 - 财政年份:2000
- 资助金额:
$ 48.08万 - 项目类别:
B VITAMIN ATHEROSCLEROSIS INTERVENTION TRAIL
B 族维生素动脉粥样硬化干预试验
- 批准号:
6196789 - 财政年份:2000
- 资助金额:
$ 48.08万 - 项目类别:
AGE, RACE, SEX AND AORTIC STIFFNESS--GENETIC MARKERS
年龄、种族、性别和主动脉僵硬——遗传标记
- 批准号:
6169424 - 财政年份:1997
- 资助金额:
$ 48.08万 - 项目类别:
AGE, RACE, SEX AND AORTIC STIFFNESS--GENETIC MARKERS
年龄、种族、性别和主动脉僵硬——遗传标记
- 批准号:
2484287 - 财政年份:1997
- 资助金额:
$ 48.08万 - 项目类别:
AGE, RACE, SEX AND AORTIC STIFFNESS--GENETIC MARKERS
年龄、种族、性别和主动脉僵硬——遗传标记
- 批准号:
2769413 - 财政年份:1997
- 资助金额:
$ 48.08万 - 项目类别:
AGE, RACE, SEX AND AORTIC STIFFNESS--GENETIC MARKERS
年龄、种族、性别和主动脉僵硬——遗传标记
- 批准号:
6372091 - 财政年份:1997
- 资助金额:
$ 48.08万 - 项目类别:














{{item.name}}会员




