课题基金 / 基金详情

SCBA Oximetry for Fire Fighter Physiologic Monitoring

SCBA Oximetry for Fire Fighter Physiologic Monitoring
用于消防员生理监测的 SCBA 血氧测定法
批准号:
6951361
负责人:
William P Wiesmann
金额:
$32.31万
依托单位:
依托单位国家:
美国
项目类别:
财政年份:
2000
资助国家:
美国
项目状态:
已结题
起止时间:
2000-09-30 至 2007-09-30

项目摘要

项目成果

William P Wiesmann的其他基金

相似基金

相关文献

中文摘要
翻译
描述(由申请人提供):本二期项目重点是通过基于自给式呼吸器(SCBA)的血氧测量系统、无线电遥测和处理软件,对佩戴个人防护装备(PPE)的人员进行远程生理状态监测,以开发一种辅助安全装置,解决消防员在对抗结构性火灾时普遍存在的意志疲劳问题。基于scba的综合监测系统能够在艰苦的工作条件下对消防员的生理状态进行无阻碍的评估,将极大地减少消防员因心脏病发作和其他生理应激表现而导致的执勤死亡,并为研究佩戴个人防护装备的工人与艰苦相关的热应激提供有价值的研究工具。在这项工作的第一阶段,建立了一个初始原型并验证了DC(血氧仪波形的非脉动成分)的急性变化与工作中的消防员的生理性疲劳相对应。拟议的第二期项目将进一步开发基于scba的监测系统,并将重点放在改进和构建下一代原型上,定义通过血氧仪波形测量的运动时的生理反应,以建立监测参数和报警阈值,并开发和评估基于直流血氧仪变化的生理相关性的算法。一旦装置被制造出来,它们将在实际的现场条件下进行评估,以证明硬度、功能和系统可靠性。迄今为止的研究和测试表明,该系统将有效地提供可靠和非侵入性的意志疲劳发作识别,并促进消防员及时自救。
英文摘要
DESCRIPTION (provided by applicant): This Phase II project focuses on remote physiologic status monitoring of personnel wearing personal protective equipment (PPE) through self-contained breathing apparatus (SCBA)-based oximetry systems, radio-telemetry and processing software for the development of an adjunct safety device addressing the prevalent problem of volitional fatigue experienced by fire fighters combating structural fires. An integrated SCBA-based monitoring system capable of unencumbered assessment of the physiological status of fire fighters under exertive working conditions would greatly serve to reduce fire fighter line-of-duty deaths attributed to heart attacks and other manifestations of physiologic stress and offers a valuable research tool for studying exertion-related heat stress in workers wearing PPE. During Phase I of this effort, an initial prototype was built and validated that acute changes in the DC, or non-pulsatile component of the oximetry waveform, correspond to physiologic fatigue in working fire fighters. The proposed Phase II project further develops the SCBA-based monitoring system, and focuses on refining and building the next generation prototype, defining the physiologic reactions to exertion as measured by the oximetry waveforms to establish monitoring parameters and alarm thresholds, and developing and evaluating algorithms based on physiologic correlations against changes in DC oximetry. Once the units are fabricated, they will be evaluated under realistic field conditions to demonstrate hardness, functionality, and system reliability. Research and testing to date suggests that this system will effectively provide reliable and non-invasive identification of the onset of volitional fatigue and facilitate timely fire fighter self-rescue.
期刊论文(0)
专著(0)
科研奖励(0)
会议论文
Bead Based Immuno-PCR for Biowarfare Agent Detection
  • 批准号:
    6555291
  • 项目类别:
  • 资助金额:
    $10.0万
  • 财政年份:
    2002
  • 负责人:
    William P Wiesmann
  • 依托单位:
SCBA OXIMETRY FOR FIRE FIGHTER PHYSIOLOGIC MONITORING
  • 批准号:
    6209628
  • 项目类别:
  • 资助金额:
    $9.97万
  • 财政年份:
    2000
  • 负责人:
    William P Wiesmann
  • 依托单位:
SCBA Oximetry for Fire Fighter Physiologic Monitoring
  • 批准号:
    6833048
  • 项目类别:
  • 资助金额:
    $42.67万
  • 财政年份:
    2000
  • 负责人:
    William P Wiesmann
  • 依托单位:
海外基金