HeartMap Dynamic AED Registry
HeartMap Dynamic AED Registry
批准号:
8668499
负责人:
Graham Nichol
金额:
$14.57万
依托单位:
依托单位国家:
美国
项目类别:
财政年份:
2013
资助国家:
美国
项目状态:
已结题
起止时间:
2013-09-15 至 2017-08-31
中文摘要
点击翻译按钮获取中文摘要
英文摘要
PROJECT SUMMARY
The long-term goal of our HeartMap Dynamic Automated External Defibrillator Registry (AED Registry) is to
ensure safety of AEDs by performing postmarket surveillance. AEDs are used to treat out-of-hospital cardiac
arrest (OHCA). Each major AEDD manufacturer has recalled their devices to address one or more potential
safety issues. Challenges with surveillance of AEDs are typical of challenges with surveillance of other medical
devices. They are mobile in space and time, as they are distributed in locations anticipated to be close to the
scene of cardiac arrest and moved periodically from one location to another. They are ubiquitous, as there are
1.2 million pre-existing devices, and about 180,000 new devices installed annually. Importantly, there is no
widely deployed method of tracking their location and use in community settings. As well, monitoring the
outcome of every AED use is necessary to identify those uses that may have caused or contributed to a death,
since the majority of patients treated for OHCA die. This study will maintain a dynamic registry for surveillance
of AED location and use so as to implement and maintain a national AED surveillance system.
Recently we developed and pilot tested a methodology to tag AEDs with a Unique Device Identifier (UDI).
According to this method, AEDs are tagged with a UDI that consists of two-dimensional matrix code (QR code,
Denso Wave Inc., Chita-gun, Japan); then the UDI as well as the location and status of the device are recorded
using open-source software native to contemporary smartphones and this information is passed to a database
in real time via the internet (Non-Provisional Patent # 61/498,424). The device-specific information in the
database is updated dynamically by rescanning the UDI after each use of the AED. We have applied UDIs to
AEDs in Philadelphia, PA and Seattle, WA.(FDA 1U01FD004587-01, Nichol, PI). Importantly, we have
leveraged this cooperative agreement with FDA to develop and implement ongoing collaborations with and
fiscal support from AED monitor/defibrillator manufacturers.
We have linked our AED Registry to EMS process and outcome benchmarking data available from the
Resuscitation Outcomes Consortium in a simple EMS registry to incent EMS agencies to participate in the AED
Registry.
Our primary aim is to provide reliable, valid and sustainable postmarket surveillance of AEDs using UDI,
smartphones and citizen engagement via crowdsourcing. We anticipate by study end an annual catchment
population of at least 20 million individuals, at least 11,192 AEDs with UDIs in public locations, at least 16,020
EMS-treated OHCA, and 2.5% of OHCA are treated with an AED by a layperson. If 80% of AEDs are known at
one year, there will be precision of 1.0% in the estimate of AED readiness for use, and 2.9% in the estimate of
survival to discharge associated with AED use.
期刊论文(0)
专著(0)
科研奖励(0)
会议论文
HeartMap Dynamic AED Registry
-
批准号:8733059
-
项目类别:
-
资助金额:$14.69万
-
财政年份:2013
-
负责人:Graham Nichol
-
依托单位:
HeartMap Dynamic AED Registry
-
批准号:8921831
-
项目类别:
-
资助金额:$5.0万
-
财政年份:2013
-
负责人:Graham Nichol
-
依托单位:
HeartMap Dynamic Registry Pilot
-
批准号:8497282
-
项目类别:
-
资助金额:$12.49万
-
财政年份:2012
-
负责人:Graham Nichol
-
依托单位:
Pilot Study of Hemofiltration after Out-of-Hospital Cardiac Arrest
-
批准号:7923218
-
项目类别:
-
资助金额:$19.5万
-
财政年份:2009
-
负责人:Graham Nichol
-
依托单位:
Pilot Study of Hemofiltration after Out-of-Hospital Cardiac Arrest
-
批准号:7739557
-
项目类别:
-
资助金额:$23.4万
-
财政年份:2009
-
负责人:Graham Nichol
-
依托单位:
国内基金
海外基金
Dynamic Credit Rating with Feedback Effects
-
批准号:--
-
项目类别:外国学者研究基金项目
-
资助金额:--
-
批准年份:2024
-
负责人:Christian Martin Hilpert
-
依托单位: