Wearable technology to reduce risk of DVT and increase patient compliance
Wearable technology to reduce risk of DVT and increase patient compliance
批准号:
9255115
负责人:
Jeffrey Schwegman
金额:
$24.42万
依托单位:
依托单位国家:
美国
项目类别:
财政年份:
2017
资助国家:
美国
项目状态:
已结题
起止时间:
2017-02-01 至 2018-07-31
关键词:
AcuteAddressAffectAgeAirAir SacsAmbulatory Surgical ProceduresAmericanAnkleAnticoagulantsAreaArizonaBed restBenchmarkingBloodBlood VesselsBlood coagulationBusinessesCapitalCaringClinicalClothingCoagulation ProcessComplicationCompression StockingComputer softwareDataDeep Vein ThrombosisDevelopmentDevicesDiabetes MellitusDiagnosisDiseaseDoctor of PhilosophyEdemaElderlyEngineeringEquipmentHealth Care CostsHealthcare MarketHome environmentHospitalizationHospitalsHygieneImmobilizationIndianaIndividualIonsLegLengthLifeLithiumLogicLong-Term CareLower ExtremityLungMalignant NeoplasmsMechanicsMedicalMedical DeviceMemoryMorbidity - disease rateObesityOperative Surgical ProceduresOrthopedic Surgery proceduresOutpatientsPainParticipantPatientsPerformancePharmacologic SubstancePhasePolypropylenesPopulationPostoperative PeriodPostphlebitic SyndromePower SourcesPregnancyPregnant WomenPreparationPreventionPulmonary EmbolismPumpRandomized Controlled TrialsRecoveryRecovery RoomRecurrenceRiskRisk FactorsSeriesSmall Business Innovation Research GrantStreamSudden DeathSurgeonSweatSymptomsSystemTechnologyTemperatureTestingThrombectomyTimeTrainingTraumaTravelTubeUnited StatesUniversitiesVena caval structureWalkingWorkbasecatalystcomparativecompliance behaviorcostdeep veindesignhandheld mobile devicehigh riskinnovationmortalitymulti-site trialpatient home carepatient populationphase changepressurepreventprofessorprototypestandard of carethrombolysisusabilitywearable technology
中文摘要
项目摘要
英文摘要
Project Abstract
Deep Vein Thrombosis (DVT) is a condition wherein a blood clot forms in a vein of the deep system. These
clots can break loose, travel through the blood stream and into the lungs causing pulmonary embolism (PE).
This is life threatening and requires immediate medical care. Each year in the United States, between 350,000
and 600,000 people get a blood clot in the legs or in the lungs, with associated costs $6B annually. DVT and
pulmonary embolism (PE) effect 2 per 1000 people and in those 80+, 1 in 100. Estimates suggest 100,000
Americans die of DVT/PE annually, 10-30% will die within one month of diagnosis and sudden death is the first
symptom in 25% of people with PE. Of those with DVT, 50% will have long-term complications, 33% will have
a recurrence within 10 years. The current standard of care for DVT/PE are blood thinners, clot busters (given
through an IV), filters inserted into the vena cava, long term use of compression stockings for prevention and
DVT cuffs, which are polypropylene air bladder wraps attached to hoses and a pump, then placed around the
lower extremities. The current standards of care are reactive to the diagnosis, invasive and expensive. Further,
they are uncomfortable and cumbersome—which significantly reduces patient compliance rates. In this SBIR,
Recovery Force, an Indiana-based small business, will use phase change memory technology, integrated logic
and a rechargeable power source to create a new DVT cuff design. The comfortable, wearable technology will
proactively address the risk of DVT/PE with increased patient compliance for people at risk of DVT/PE,
including individuals with diabetes, the elderly, pregnant women, and cancer as well as post-operative patients.
Recovery Force will achieve the following Phase I Aims: Aim 1) Conduct Comparative Engineering
Testing: Determine that desired benchmark is consistent with available DVT cuffs in clinical use with an air
bladder pressures15, cycle time, contact area and temperature. All design and testing requirements will be
performed under the Recovery's Force's quality system ISO33875 in preparation for a FDA 510(k) Class II
medical device submission. Aim 2) Conduct a preliminary clinical usability study to assess comfort,
acceptance, ease of use and design. The primary hypothesis is following optimizing the prototype,
participants will be strongly statisfied with design, comfort and wearability of the product. It is also predicted
that their acceptance to wearing the device will be high. The PI will work with subawardee Dr. Armstrong
(UofAz) to conduct a preliminary usability study. At the conclusion of Phase I, the Recovery Force will have
demonstrated the feasibility of a new DVT-focused compression product that will allow the user to be mobile,
be made out of comfortable material, achieve similar (or better) results than existing solutions and offer
increased patient compliance. Phase II will focus on a larger scale multi-site trial for use in the healthcare
market with testing in recovery rooms and long term care facilities.
期刊论文(0)
专著(0)
科研奖励(0)
会议论文
Wearable technology to reduce risk of DVT and increase patient compliance
-
批准号:9899295
-
项目类别:
-
资助金额:$82.14万
-
财政年份:2017
-
负责人:Jeffrey Schwegman
-
依托单位:
海外基金