课题基金 / 基金详情

Beyond the pump: a novel shape memory alloy penile prosthesis

Beyond the pump: a novel shape memory alloy penile prosthesis
超越泵:新型形状记忆合金阴茎假体
批准号:
9909387
负责人:
Alberto Colombo
金额:
$26.69万
依托单位:
依托单位国家:
美国
项目类别:
财政年份:
2015
资助国家:
美国
项目状态:
已结题
起止时间:
2015-09-20 至 2023-08-31

项目摘要

项目成果

相似基金

相关文献

中文摘要
翻译
点击翻译按钮获取中文摘要
英文摘要
Abstract Erectile dysfunction (ED) is a multifactorial disease that affects approximately 39 million American men and is continuing to increase with the increasing prevalence of diabetes, hypertension and cardiovascular disease. When first line and second line medications such as the phosphodiesterase 5 inhibitor (PDE5i) class of medications or direct injections fail, surgical implantation of penile prostheses offers a permanent solution. Approximately 1/3 of men with ED will ultimately fail treatment with PDE5i yielding a potential market of 10 million men. The two broad classes of penile prostheses commercially available are: the inflatable prosthesis and the semi-rigid prosthesis. The inflatable penile prosthesis relies on a closed system of reservoirs, pumps, valves and hydraulic pressure to produce a simulated erection sufficient for intromission and coitus. The malleable is a bendable rod. Neither device offers the ideal balance of being a robust, reliable, simple and discrete treatment for male ED. The patient and physician perceptions on these device solutions are being too complex, not reliable, and not physiologic and the cosmetic appearance is partly responsible as well for the modest uptake of surgical implantation of prostheses as treatment of their erectile dysfunction compared to the number of potential candidates. Thus there is a need for a simple, robust surgical solution for men with refractory erectile dysfunction that appears as physiologic as possible, yet remains discrete and balances the various risks and benefits of the above solutions. Uronext product is a solution that relies on the molecular rearrangement of a metal alloy to produce a simulated erection. As such, it has a much smaller profile, is very discrete, and relies on the intrinsic properties of the metal and is thus very reliable. Such a design has the possibility to open the door to more widespread acceptance of prostheses for the treatment of ED similar to the more widespread acceptance of breast implants (200,000 procedures per year). Furthermore, the much simpler and faster procedure will allow a much greater number of urologists and physicians to propose this solution to their patients.
期刊论文(2)
专著(0)
科研奖励(0)
会议论文
海外基金