INVESTIGATING THE PREDICTIVE VALUE OF FETAL ECG IN NST AND CST
INVESTIGATING THE PREDICTIVE VALUE OF FETAL ECG IN NST AND CST
批准号:
7605464
负责人:
Rodney K. Edwards
金额:
$0.18万
依托单位:
依托单位国家:
美国
项目类别:
财政年份:
2006
资助国家:
美国
项目状态:
已结题
起止时间:
2006-12-23 至 2007-11-30
关键词:
AbdomenAccelerationCervix UteriComputer Retrieval of Information on Scientific Projects DatabaseDataDatabasesDigital Signal ProcessingDiscipline of obstetricsElectrocardiogramElectrodesEnrollmentFetal Heart RateFetal MovementFundingGrantHeart RateHigh-Risk PregnancyInformed ConsentInstitutionInvasiveMeasuresMedicalMedical RecordsMonitorNeonatalOutcomePatientsPersonal ComputersPersonal SatisfactionPilot ProjectsPredictive ValuePregnancyPregnant WomenResearchResearch PersonnelResourcesScalp structureSignal TransductionSourceSpecificityStress TestsTechniquesTestingUltrasonicsUltrasonographyUnited States National Institutes of HealthWeekWritingabstractingantepartum testingcomputerizedfetalimprovedintrapartumprospectiveresponse
中文摘要
点击翻译按钮获取中文摘要
英文摘要
This subproject is one of many research subprojects utilizing the
resources provided by a Center grant funded by NIH/NCRR. The subproject and
investigator (PI) may have received primary funding from another NIH source,
and thus could be represented in other CRISP entries. The institution listed is
for the Center, which is not necessarily the institution for the investigator.
Fetal well-being in high-risk pregnancies is assessed with serial antenatal testing after 23 weeks gestation. Frequently employed is the non-stress test (NST), which evaluates the fetal heart rate (FHR) response to fetal movements. The resulting FHR tracing is evaluated visually by a clinician for the presence of accelerations and beat-to-beat variability.
A non-reassuring NST may be followed by a contraction stress test (CST), during which FHR response to contractions is monitored, or a biophysical profile (an ultrasound assessment of fetal activity). While the specificity of NSTs and CSTs is relatively high (>90%), the sensitivity is fairly low (45-55%).
Recent studies suggest computerized analysis of the heart rate variability may improve the predictive value. 1 The accuracy of this assessment is enhanced when measured directly from the fetal ECG (FECG), rather than by ultrasonic determination of FHR. Furthermore the FECG waveform contributes information that more accurately predicts fetal well-being intrapartum.2 Unfortunately, acquisition of the FECG is invasive (a wire electrode placed on the fetal scalp via the maternal cervix) and not available during antepartum testing.
We propose a prospective observational pilot study that will enroll approximately 200 pregnant women between 24 and 43 weeks who present for antenatal testing. Following written, informed consent, abdominal electrodes will be placed and electrical data collected to a personal computer for subsequent analysis. Demographic and relevant maternal, delivery and neonatal medical information will be abstracted from medical records.
Advanced digital signal processing techniques will be applied to the abdominal electrical signal to extract the FECG, features of which will be recorded. This database of patients presenting serially for antenatal testing, and their obstetric outcome, will be analyzed to determine the additive value of FECG in predicting neonatal outcome.
期刊论文(0)
专著(0)
科研奖励(0)
会议论文
INVESTIGATING THE PREDICTIVE VALUE OF FETAL ECG IN NST AND CST
-
批准号:7374664
-
项目类别:
-
资助金额:$2.76万
-
财政年份:2005
-
负责人:Rodney K. Edwards
-
依托单位:
INVESTIGATING THE PREDICTIVE VALUE OF FETAL ECG IN NST AND CST
-
批准号:7202974
-
项目类别:
-
资助金额:$0.32万
-
财政年份:2004
-
负责人:Rodney K. Edwards
-
依托单位:
INVESTIGATING THE PREDICTIVE VALUE OF THE ELECTROHYSTEROGRAM IN PRETERM LABOR
-
批准号:7202945
-
项目类别:
-
资助金额:$1.19万
-
财政年份:2004
-
负责人:Rodney K. Edwards
-
依托单位:
Explaining Bacterial Vaginosis Risk Factor for Preterm Delivery
-
批准号:7041163
-
项目类别:
-
资助金额:$0.75万
-
财政年份:2003
-
负责人:Rodney K. Edwards
-
依托单位:
海外基金