Computer assisted coronary artery stent interventions
Computer assisted coronary artery stent interventions
批准号:
9589254
负责人:
Hiram Bezerra
金额:
$74.35万
依托单位国家:
美国
项目类别:
财政年份:
2018
资助国家:
美国
项目状态:
已结题
起止时间:
2018-07-01 至 2022-05-31
关键词:
AcuteAddressAreaArteriesAtherectomyBalloon AngioplastyBalloon DilatationBiomechanicsCaliberClinicalComputer AssistedComputer SimulationComputer softwareCoronary StenosisCoronary arteryDataData SetDevicesDissectionDistalElementsEvaluationEventFocus GroupsFractureFutureGuidelinesImageImage AnalysisInterventionInvestigationLeadLengthLesionLicensureLightMeasurementMethodologyMethodsMicrodissectionModelingModificationOptical Coherence TomographyOutcomePredictive Value of TestsProcessQuantitative EvaluationsResearchResolutionRoentgen RaysRoleRuptureStentsStressTechniquesTechnologyTestingThickTimeTissuesWorkX-Ray Computed Tomographyaging populationbiomechanical modelcalcificationclinical imagingclinical practicecoronary artery calcificationexperimental studyimaging modalityimprovedinsightmetallicitymicroscopic imagingpredictive modelingpressurequantitative imagingsuccesstreatment choicetreatment guidelinestreatment optimizationtreatment planningtreatment strategy
中文摘要
计算机辅助冠状动脉支架介入治疗
英文摘要
Computer assisted coronary artery stent interventions
Summary
When treating highly calcified coronary artery lesions with stents, interventional cardiologists, with limited in-
formation, make stressful treatment decisions, which can lead to inadequate stent deployment and poor out-
comes, or even rare calamitous events. When calcification is present, a cardiologist must choose to use a
normal sized angioplasty balloon; a larger angioplasty balloon with increasingly high, prolonged pressures to
fracture the calcification; a scoring or cutting balloon; any one of a number of atherectomy devices; and/or
stent post-dilation balloon pressures up to 30 atm. The cardiologist must choose stent diameter and length,
taking into account distal artery size, vessel taper, and extent (arc length and thickness) of calcification. Some
potential negative consequences are that a stent can under deploy and/or have malapposed struts; a balloon
can rupture; a vessel can dissect; or an atherectomy device can perforate the wall. Intravascular optical coher-
ence tomography (IVOCT) evaluations of stent deployment show that large eccentric calcifications often lead
to under deployment with malapposition of struts and small vessel dissections. To address these challenges,
specific aims are: 1) Develop methods for imaging/quantifying calcifications in pre-stent images. 2) Perform ex
vivo experiments to obtain detailed biomechanical data and demonstrate key issues in stent deployment.
3) Develop well-validated, lesion specific FEM models. 4) Use in silico experiments and physical measure-
ments to elucidate issues in stent deployment and establish guidelines for treatment. With success, the project
will lead to future decision-support software for live-time treatment planning from IVOCT or other imaging mo-
dalities. The project team will build on expertise in interventions, quantitative image analysis of IVOCT, and fi-
nite element modeling.
期刊论文(0)
专著(0)
科研奖励(0)
会议论文
Magnetic Resonance Imaging Guided Robotic Catheter System for Left Atrial Appendage Occlusion Procedures
-
批准号:10666474
-
项目类别:
-
资助金额:$84.61万
-
财政年份:2022
-
负责人:Hiram Bezerra
-
依托单位:
Computer assisted coronary artery stent interventions
-
批准号:10201734
-
项目类别:
-
资助金额:$68.9万
-
财政年份:2018
-
负责人:Hiram Bezerra
-
依托单位:
In vivo Characterization of Stents using Intravascular OCT Imaging
-
批准号:8529140
-
项目类别:
-
资助金额:$41.29万
-
财政年份:2013
-
负责人:Hiram Bezerra
-
依托单位:
In vivo Characterization of Stents using Intravascular OCT Imaging
-
批准号:9097737
-
项目类别:
-
资助金额:$44.74万
-
财政年份:2013
-
负责人:Hiram Bezerra
-
依托单位:
In vivo Characterization of Stents using Intravascular OCT Imaging
-
批准号:8724992
-
项目类别:
-
资助金额:$40.25万
-
财政年份:2013
-
负责人:Hiram Bezerra
-
依托单位:
海外基金