Non-contrast MRI of RF Ablation Lesions in the Treatment of Cardiac Arrhythmia
Non-contrast MRI of RF Ablation Lesions in the Treatment of Cardiac Arrhythmia
批准号:
9340210
负责人:
Aravindan Kolandaivelu
金额:
$24.53万
依托单位:
依托单位国家:
美国
项目类别:
财政年份:
2016
资助国家:
美国
项目状态:
已结题
起止时间:
2016-09-01 至 2019-06-30
关键词:
AblationAcuteAddressAffectAftercareAnatomyAppearanceAreaArrhythmiaBloodCardiac ablationCatheterizationCathetersChronicCicatrixContrast MediaDarknessDevelopmentDisadvantagedEdemaEvaluationEvolutionFamily suidaeFibrosisFluoroscopyFutureGadoliniumGoalsHeartHistologyImageImage EnhancementImageryImaging TechniquesInjection of therapeutic agentInjuryInvestigationKineticsLeadLesionLocationMagnetic Resonance ImagingMapsMethodsMonitorMyocardialMyocardial InfarctionMyocardial tissueMyocardiumNecrosisNecrotic LesionOutcomePatientsPharmaceutical PreparationsPhysiologic pulseProceduresProcessProtocols documentationRadiofrequency Interstitial AblationRecurrenceRoentgen RaysSudden DeathTechniquesTestingThickThinnessTimeTissuesUltrasonographyUnited StatesWorkbaseclinical applicationcontrast imagingdosageimaging modalityimprovedinterestscreening
中文摘要
点击翻译按钮获取中文摘要
英文摘要
Cardiac arrhythmias affect millions of people in the United States. Many are prescribed
medication, but more severe cases are treated with RF ablation of myocardial (heart muscle) tissue, administered by
catheterization. Ablation targets are typically chosen using electro-anatomical (EA) mapping,
where a sensing catheter is placed at many locations in the heart chamber to analyze the
electrograms and determine where reentrant circuits may be occurring. Using this information, an
ablation catheter is then navigated to those targets, using x-ray fluoroscopy and the EA map.
However, since myocardium is all but invisible in x-ray, targeting inaccuracies are frequent. It is
also impossible to tell with any certainty which areas have been ablated (the lesions), and to what
extent, or if any gaps still exist. As a result, recurrence of arrhythmias after ablation therapy
is quite common, requiring repeated treatment. These shortcomings can be addressed with magnetic
resonance imaging (MRI). With MRI, myocardium is readily visible, easily distinguishable from
blood, and sufficient detail is available to recognize anatomical landmarks, al, of which can
improve targeting accuracy.
Typical MR imaging methods for visualizing ablation lesions employ a T1Cshortening
gadolinium-based contrast agent (GBCA) to identify damaged or dead tissue. In healthy myocardium,
contrast agent washes in then washes out over a few minutes. In necrotic myocardium, the wash out
process is compromised, so the contrast agent remains in the tissue and is enhanced in T1Cweighted
MR images, referred to as late gadolinium enhancement (LGE). However, the need for a contrast agent
in current methods is a disadvantage for multiple reasons. There are complexities in image
interpretation and dosage limitations, limiting utility in monitoring treatment. For visualizing
ablation lesions acutely, we have developed an efficient MR imaging technique which does
not require the use of contrast agent. This method, which we hope to develop, optimize and test in
this proposal, shows enhancement in the necrotic (dead) region of the lesion, with edema seen as a
dark band around the enhancement. Our preliminary results show reliable and readily seen lesions in
both thick and thin myocardial walls. This could be of great benefit before (screening, planning),
during (targeting, assessing) or after (evaluating) an ablation procedure.
In obtaining our preliminary results, we have chosen imaging parameters which produce readily
visible contrast between ablation lesions, normal myocardium and cavitary blood. We wish to improve
and validate the technique, optimizing imaging parameters and protocols, study the results, and
investigate how this may be used in clinical application.
Lesion images obtained with the proposed technique may be used to guide an ablation procedure
whether performed under guidance of x-ray/ultrasound (typical) or MRI (under investigation). In
either case, this technique can be used to evaluate the treatment, by answering the question:
Have all target regions of myocardium been ablated to the point of necrosis, which is known to
cause lasting conduction block? Images such as these will help to determine whether the procedure
is finished, or if further ablations are required to complete coverage. Future study can follow
patients to evaluate the impact on recurrence.
期刊论文(0)
专著(0)
科研奖励(0)
会议论文
Atrial fibrillation ablation assessment and guidance using native-contrast T1 weighted MRI
-
批准号:10658984
-
项目类别:
-
资助金额:$78.27万
-
财政年份:2021
-
负责人:Aravindan Kolandaivelu
-
依托单位:
Atrial fibrillation ablation assessment and guidance using native-contrast T1 weighted MRI
-
批准号:10468753
-
项目类别:
-
资助金额:$78.6万
-
财政年份:2021
-
负责人:Aravindan Kolandaivelu
-
依托单位:
Atrial fibrillation ablation assessment and guidance using native-contrast T1 weighted MRI
-
批准号:10182527
-
项目类别:
-
资助金额:$78.27万
-
财政年份:2021
-
负责人:Aravindan Kolandaivelu
-
依托单位:
Non-contrast MRI of RF Ablation Lesions in the Treatment of Cardiac Arrhythmia
-
批准号:9227084
-
项目类别:
-
资助金额:$20.38万
-
财政年份:2016
-
负责人:Aravindan Kolandaivelu
-
依托单位:
Cardiac Magnetic Resonance IMaging During Arrhythmia
-
批准号:8290337
-
项目类别:
-
资助金额:$13.97万
-
财政年份:2011
-
负责人:Aravindan Kolandaivelu
-
依托单位:
Cardiac Magnetic Resonance IMaging During Arrhythmia
-
批准号:8882525
-
项目类别:
-
资助金额:$13.97万
-
财政年份:2011
-
负责人:Aravindan Kolandaivelu
-
依托单位:
Cardiac Magnetic Resonance IMaging During Arrhythmia
-
批准号:8505026
-
项目类别:
-
资助金额:$13.97万
-
财政年份:2011
-
负责人:Aravindan Kolandaivelu
-
依托单位:
Cardiac Magnetic Resonance IMaging During Arrhythmia
-
批准号:8091850
-
项目类别:
-
资助金额:$13.97万
-
财政年份:2011
-
负责人:Aravindan Kolandaivelu
-
依托单位:
海外基金