Advanced transepithelial corneal collagen crosslinking

Advanced transepithelial corneal collagen crosslinking
先进的跨上皮角膜胶原交联
批准号:
10741684
负责人:
David Huang
金额:
$41.23万
依托单位国家:
美国
项目类别:
财政年份:
2023
资助国家:
美国
项目状态:
未结题
起止时间:
2023-09-01 至 2025-08-31

项目摘要

项目成果

David Huang的其他基金

相似基金

相关文献

中文摘要
翻译
点击翻译按钮获取中文摘要
英文摘要
PROJECT SUMMARY Keratoconus is an eye disease where the cornea is mechanically weakened, leading to progressive thinning, distortion, and degradation of vision. In severe cases, corneal transplantation may be required to restore vision. Corneal collagen crosslinking (CXL) is a procedure that uses riboflavin, oxygen and ultraviolet (UV) light to produce a chemical reaction that strengthens collagen fibers in the cornea stroma. CXL has been shown to halt keratoconus progression over the long term. A problem with the standard CXL procedure is that the surface epithelial cells must be removed first so that riboflavin, oxygen, and UV can easily enter the corneal stroma. It is common for epithelial healing to be delayed after CXL. This increases the chance that the cornea may become hazy. It also increases the risk of infections that can lead to scarring and loss of vision. To avoid these problems, some doctors perform CXL without removing the epithelium. This is called “transepithelial CXL” in contrast to the standard “epi-off CXL” procedure. Unfortunately, as currently practiced, transepithelial CXL is far less effective in strengthening the cornea. We have developed an advanced transepithelial CXL technology (Casey CXL) that overcomes the epithelial barrier to riboflavin, oxygen, and UV delivery. A computational finite- element model (FEM) of diffusion and reaction kinetics showed that Casey CXL can significantly exceed the performance of standard epi-off CXL. We propose to validate the advantages of Casey CXL in ex vivo experiments using both rabbit and human eye bank corneas: 1. Construct an oxygen-UV delivery system to enrich oxygen to >90% in the ambient air over the corneal surface during UV irradiation. 2. Measure oxygen concentration in the corneal stroma during CXL. We will use a fiber-optics oximetry probe to measure oxygen in the anterior and mid-stroma during UV irradiation. We will test the hypothesis that by using oxygen enrichment and pulsed UV, Casey CXL allows greater oxygen penetration to the mid-stroma than standard epi-off CXL. The FEM predicts a more than 2-fold advantage for Casey CXL, which would greatly improve the depth of corneal strengthening. 3. Use optical coherence tomographic elastography, a nondestructive testing technology, to measure cornea stiffness before and after experimental CXL. This would test the hypothesis that Casey CXL can stiffen the cornea more than standard epi-off CXL, as predicted by the FEM. These experiments would validate the Casey CXL protocol, including the drug formulation, procedure steps, and oxygen-UV delivery device, to prepare for clinical trials in human patients.
期刊论文(0)
专著(0)
科研奖励(0)
会议论文
Applications of ultrahigh-speed long-range wide-field OCT in anterior eye diseases
Functional and Structural Optical Coherence Tomography for Glaucoma
Functional and Structural Optical Coherence Tomography for Glaucoma
Functional and Structural Optical Coherence Tomography for Glaucoma
海外基金