High Performance Seizure Monitoring and Alert System
High Performance Seizure Monitoring and Alert System
批准号:
7611104
负责人:
Deng-Shan Shiau
金额:
$26.24万
依托单位国家:
美国
项目类别:
财政年份:
2009
资助国家:
美国
项目状态:
已结题
起止时间:
2009-03-01 至 2010-08-28
关键词:
Accident and Emergency departmentAcuteAlgorithmsAmplifiersAreaAuditory SeizureBrainCaringClinicalClinical ResearchCommunity HospitalsComputer Systems DevelopmentComputer softwareComputersCritical CareDataDetectionDevelopmentDevice DesignsDevicesDiagnosisDrug Delivery SystemsElectrodesElectroencephalographyEnvironmentEpilepsyEvaluationEventFeedbackGeneral HospitalsGoalsHeadHealth PersonnelHeartHospitalsHousingHuman ResourcesInfectionInpatientsInstructionIntensive CareIntensive Care UnitsMailsMetabolic DiseasesMonitorNeurologicNeurologistNeurologyNeurosciencesNursing StaffOperative Surgical ProceduresOutputPatient AdmissionPatientsPatternPerformancePhasePhysiciansProcessReadingResearchResearch DesignResearch PersonnelRespiratory physiologyScalp structureSecureSeizuresSignal TransductionSimulateSiteStreamStrokeSubclinical SeizuresSystemTestingTimeTrainingTraumaVisualanalogbaseclinical applicationclinical carecommercializationdata acquisitiondesigndigitalelectric impedancegraphical user interfaceimprovedinterestnovelpoint of careprototypepublic health relevancesimulationspatiotemporalstandard of careuser-friendly
中文摘要
点击翻译按钮获取中文摘要
英文摘要
DESCRIPTION (provided by applicant): Patients are frequently hospitalized for management of uncontrolled seizures due to epilepsy or acute neurological insults such as trauma, stroke, infections, and a number of toxic and metabolic disorders. Inpatient management of seizures is complicated by the fact that they occur intermittently and unpredictably. Researchers at Optima Neuroscience have developed an automated algorithm to accurately detect seizures by analyzing the spatiotemporal patterns of scalp EEG signals. We propose to commercialize this algorithm into a user-friendly seizure monitoring and alert (SMA) system for clincial research as well as for bedside use in hospital epilepsy monitoring and intensive care units. For such a system to be clinically useful, it is imperative that the detection algorithm must perform with a high sensitivity and low false detection rate. In Phase I, we will develop and test an SMA prototype that will (1) read and process on-line real-time EEG signals as designed in the Optima seizure detection algorithm; (2) generate an alert when an event is detected, and (3) send selected EEG segments containing the detected event to the physician for verification. This prototype will serve as the basis for subsequent devices designed specifically for two clinical applications: (1) Epilepsy Monitoring Units, and (2) Intensive Care Units. Successful commercialization of this SMA device will improve inpatient management of seizures by allowing for detection of intermittent and previously misdiagnosed events. PUBLIC HEALTH RELEVANCE: Although automated monitoring for critical heart and lung function is the standard of care in all hospitals, monitoring the function of the brain currently relies almost exclusively upon bedside clinical observations. As a result, a large number of subclinical seizures (only subtle observable changes) go undiagnosed every day. The primary goal of this project is to build and test a prototype for a greatly needed automated system to alert staff untrained in neurology to the presence of seizure activities. The overall goal is to improve the diagnosis and treatment of patients suffering from seizure disorders, particularly in community hospitals where EEG trained neurologist may not be available.
期刊论文(3)
专著(0)
科研奖励(0)
会议论文
Seizure Detection Software Used to Complement the Visual Screening Process for Long-Term EEG Monitoring.
癫痫发作检测软件用于补充长期脑电图监测的视觉筛查过程。
DOI:
--
发表时间:
2010
期刊:
American journal of electroneurodiagnostic technology
影响因子:
--
作者:
[Halford,JonathanJ, Shiau,Deng-Shan, Kern,RyanT, Stroman,ConradA, Kelly,KevinM, Sackellares,JChris]
通讯作者:
Sackellares,JChris
Quantitative EEG analysis for automated detection of nonconvulsive seizures in intensive care units.
DOI:
10.1016/j.yebeh.2011.08.028
发表时间:
2011-12
期刊:
Epilepsy & behavior : E&B
影响因子:
--
作者:
[Sackellares JC, Shiau DS, Halford JJ, LaRoche SM, Kelly KM]
通讯作者:
Kelly KM
Validation of a Novel Automated Seizure Detection and EEG Trending System for Con
-
批准号:8313582
-
项目类别:
-
资助金额:$33.31万
-
财政年份:2012
-
负责人:Deng-Shan Shiau
-
依托单位:
High Performance Seizure Monitoring and Alert System
-
批准号:8978535
-
项目类别:
-
资助金额:$67.96万
-
财政年份:2009
-
负责人:Deng-Shan Shiau
-
依托单位:
High Performance Seizure Monitoring and Alert System
-
批准号:8057582
-
项目类别:
-
资助金额:$74.48万
-
财政年份:2009
-
负责人:Deng-Shan Shiau
-
依托单位:
High Performance Seizure Monitoring and Alert System
-
批准号:8522316
-
项目类别:
-
资助金额:$68.94万
-
财政年份:2009
-
负责人:Deng-Shan Shiau
-
依托单位:
High Performance Seizure Monitoring and Alert System
-
批准号:8338452
-
项目类别:
-
资助金额:$72.04万
-
财政年份:2009
-
负责人:Deng-Shan Shiau
-
依托单位:
High Performance Seizure Monitoring and Alert System
-
批准号:9113659
-
项目类别:
-
资助金额:$62.92万
-
财政年份:2009
-
负责人:Deng-Shan Shiau
-
依托单位:
海外基金