Compact CT Robust to Patient Motion for the Neuro ICU and OR
Compact CT Robust to Patient Motion for the Neuro ICU and OR
批准号:
7801540
负责人:
Matthew William Jacobson
金额:
$17.62万
依托单位:
依托单位国家:
美国
项目类别:
财政年份:
2010
资助国家:
美国
项目状态:
已结题
起止时间:
2010-04-15 至 2012-04-14
关键词:
AccidentsAdverse eventAlgorithmsAneurysmBone TissueBrainBrain hemorrhageBreathingCathetersClinicClinicalClinical ResearchComputer softwareComputersConfined SpacesDataDeep Brain StimulationDentalDetectionDevelopmentDevicesDiagnosisEarEquipmentEstimation TechniquesExhibitsFeedbackFinancial compensationFundingGoalsHeadHead and neck structureHemorrhageHospitalsHuman ResourcesHuman VolunteersImageImaging DeviceImaging TechniquesImplantIncidenceIndustryInfarctionIntensive Care UnitsLeadLifeLocationManufacturer NameMarketingMeasurementMeasuresMechanicsMedicalMethodsMicrocomputersMonitorMorbidity - disease rateMorphologic artifactsMotionMovementNeurologicNeurosurgeonNorth AmericaNoseOccupationsOperating RoomsOperative Surgical ProceduresOtolaryngologyPatientsPerformancePharyngeal structurePhasePositioning AttributeProceduresProcessRadio-OpaqueRecruitment ActivityResearch Ethics CommitteesSafetySalesScanningSeriesShunt DeviceSimulateSmall Business Innovation Research GrantSourceSpecific qualifier valueSupervisionSystemTechnologyTestingTimeTomography, Computed, ScannersVentricularX-Ray Computed Tomographycommercializationcostdeep brain stimulatordetectorhazardimage reconstructionimprovedinnovationmeetingsmillimeternon-compliancepoint of carepublic health relevanceresearch studyrestraintsoft tissue
中文摘要
描述(由申请人提供):平板探测器和微型计算机的最新进展使紧凑和移动计算机断层扫描(CT)成像设备在牙科和耳鼻喉科应用中取得成功,并显示出神经学成像应用的前景。然而,未服用镇静剂的神经系统疾病患者在扫描过程中往往会移动,这会降低软组织/大脑观察窗口的图像质量。提出了一种新颖的方法来补偿患者的运动,以恢复CT检查的图像质量。该方法由软件算法组成,通过投影数据估计和纠正患者的运动,采用廉价且易于获得的无线电不透明标记。这项技术有可能提高ICU、CCU和OR神经成像的及时性、安全性和可靠性。示例应用包括监测或检测出血和梗死,评估脑移位和压迫,放置心室分流导管和深部脑刺激。第一阶段将致力于运动补偿方法的发展,并展示足够的成像性能。测试数据将从模拟脑出血的头部幻影受试者和在测试台上真实的机械诱导运动中获得。将开发一种算法,从附着在头部的无线电不透明标记的x射线投影中准确估计受试者的运动。将开发另一种算法来重建图像,并结合运动估计。端到端测试将根据临床医生的反馈进行。在第二阶段,提议的设备将被简化,包括算法加速,以便在临床环境中实际使用。将进行临床研究,以评估和完善商业推出的方法。该系统的商业机会估计在10年内在美国将超过5000个系统,这将创造大约100个就业机会。
英文摘要
DESCRIPTION (provided by applicant): Recent advances in flat-panel detectors and microcomputers have enabled compact and mobile computed tomography (CT) imaging devices to be successful in dental and otolaryngology applications, and show promise for neurological imaging applications. However unsedated patients with neurological conditions tend to move during the scan which degrades image quality in the soft-tissue / brain viewing windows. This proposal presents an innovative method to compensate for patient movement to restore image quality for CT exams. The method consists of software algorithms to estimate and correct patient movement from the projection data, employing inexpensive and readily available radio-opaque markers. This technology has the potential to improve timeliness, safety, and reliability of neuro-imaging in the ICU, CCU, and OR. Example applications include monitoring or detecting bleeds and infarcts, evaluating brain shift and compression, placing ventricular shunt catheters, and deep brain stimulation. Phase 1 will be devoted to the development of the motion compensation method and to demonstrating adequate imaging performance. Test data will be obtained from a head phantom subject with simulated brain hemorrhages and with realistic, mechanically-induced movement on a testbed. An algorithm will be developed to accurately estimate subject movement from the x-ray projections of radio-opaque markers attached to the head. Another algorithm will be developed to reconstruct images, incorporating the motion estimates. End-to-end tests will be performed with clinician feedback. In phase 2, the proposed device will be streamlined, including algorithm speedup, to enable practical use in clinical settings. Clinical studies will be performed to evaluate and refine the method for commercial launch. The commercial opportunity for the system is estimated to be over 5000 systems in the USA over 10 years, which would lead to the creation of approximately 100 jobs.
PUBLIC HEALTH RELEVANCE: Recently emergent compact CT devices can perform head CT scans directly in the ICU, CCU, and OR, and therefore have the potential to improve timeliness, safety, and reliability of neuro- imaging. An obstacle to fulfilling this potential is that these systems have longer scanning times than conventional CT devices, making imaging performance more vulnerable to patient motion. To overcome this obstacle, this project proposes to combine a highly compact, mobile flat panel CT system with a method for motion compensation.