AcuteAffectAntibodiesBiocompatible MaterialsBrain StemCerebrospinal FluidCessation of lifeClinicalComplicationComputersDehydrationDetectionDevelopmentDevicesDiagnosticDiagnostic ProcedureDiagnostic testsElectrophoresisEnzyme-Linked Immunosorbent AssayEnzymesEquipmentEvaluationExtravasationFailureGoalsGoldHospitalsHuman ResourcesImaging TechniquesImmunoassayIn TransferrinInjuryLateralMagnetic Resonance ImagingMeningitisMethodsMicrofluidicsModalityNatureNoseOne-Step dentin bonding systemOperating RoomsOperative Surgical ProceduresOtolaryngologyPaperPatientsPerformancePhasePhysiciansPolyacrylamide Gel ElectrophoresisPostoperative CarePostoperative PeriodProbabilityProceduresProteinsReagentResearchResearch PersonnelRiskRoleSamplingSensitivity and SpecificitySet proteinSignal TransductionSiteSodium Dodecyl SulfateSpinal CordStagingSystemTechnologyTestingTimeTissuesTrainingTransferrinTranslatingaqueousbasecostdesignhigh rewardhigh riskimprovedneurosurgerynext generationnovelpoint of carepreventprimary outcomeprototyperapid detectionrepairedresearch studyskull basetomography
中文摘要
项目总结
英文摘要
PROJECT SUMMARY
Cerebrospinal fluid (CSF) leak is a common complication of numerous procedures in otolaryngology. It has
been estimated that up to 13.8% of endoscopic skull base surgeries result in CSF leaks. In the acute setting,
imaging techniques such as magnetic resonance imaging (MRI) or computer tomography (CT) are used for
assessment. Patients with high enough clinical suspicion may be taken directly to the operating room for
management, which involves identifying the site of the leak and using either native tissue or biocompatible
materials to patch the affected site. It is often difficult, however, to detect CSF leaks in clinical or postoperative
hospital settings, as it is not unusual for postoperative patients to have secretions, and therefore distinguishing
normal secretions from those containing CSF can be challenging. Failure to recognize and repair a leak can
result in severe complications, such as meningitis, brainstem herniation, and death. Currently, there are no
proven, available tests that allow a physician, who is concerned about a CSF leak, to cheaply and non-
invasively rule out the presence of a leak. As a result, physicians must return to the same diagnostic modalities
that are used in the acute setting. However, the costly and invasive nature of these diagnostic tests make them
difficult to justify in a patient who seems otherwise well. Alternative methods have been developed for the
detection of CSF leaks, such as beta-2 transferrin electrophoresis or enzyme-linked immunosorbent assay
(ELISA); however, they are rarely used due to high cost and long time-to-result. More recently, researchers
have looked into the detection of beta-trace protein (TP) and found it to be comparable to beta-2 transferrin in
sensitivity and specificity for CSF. Although used in a research setting, this protein has yet to be used for
clinical detection.
The main goal of this project is to develop a next generation, rapid, inexpensive and simple diagnostic device
for detection of CSF leaks. The device will incorporate a sample pre-concentration step using the aqueous two-
phase system (ATPS), colorimetric enzymes for signal amplification, and a rapid lateral-flow immunoassay
(LFA) for detection. The traditional LFA is not sensitive enough for the detection of TP at the relevant
concentrations. To overcome this barrier, the ATPS can be used to concentrate the target protein by several
orders of magnitude prior to LFA detection. By using paper microfluidics, we have demonstrated that our
device can simultaneously and seamlessly concentrate and detect target proteins. To improve the LFA
detection limit even further, we have demonstrated the feasibility of using the ATPS as a novel method of
sequentially delivering signal enhancement reagents across a detection zone. We will develop the prototypes
of our device using two approaches: a “low-hanging fruit” two-stage platform, and a “high-risk, high-reward”
one-stage platform. Once fully developed, the device will allow clinicians to more rapidly detect and treat CSF
leaks, as well as be used to prevent patients who otherwise appear well from receiving expensive and invasive
studies and procedures. Furthermore, such a device is not limited to the field of otolaryngology, but may also
find use in identifying injuries to the spinal cord or globe, and may have a role in ruling out a CSF leak in
postoperative neurosurgical patients with a low pretest probability of having a leak.