直线扫描内CT及其动态Bowtie研究
项目介绍
AI项目解读
基本信息
- 批准号:61471070
- 项目类别:面上项目
- 资助金额:85.0万
- 负责人:
- 依托单位:
- 学科分类:F0125.医学信息检测与处理
- 结题年份:2018
- 批准年份:2014
- 项目状态:已结题
- 起止时间:2015-01-01 至2018-12-31
- 项目参与者:蔡玉芳; 段黎明; Wenxiang Cong; 王成祥; 谷明辉; 覃磊; 王志;
- 关键词:
项目摘要
New techniques for movable ultra-low-cost x-ray CT scanners are in instant and great needs for military, war areas, developing countries, especially for rural areas. And for the new CT techniques, methods for radiation dose reduction should be taken into consideration. In this project, we proposed a translation based interior CT scheme which is inspired by the recently developed compressive sensing and interior tomography techniques, and proposed a dynamic bowtie scheme for cone-beam CT which consists of a high-density bowtie (HBT) filled in with heavy liquid and a low-density bowtie (LBT) immersed in the liquid of the HBT. In the CT scheme, the source and detector are translated in opposite directions for ROI reconstruction with one or more localized linear scans, among which the one-translation scan is similar to the digital tomosynthesis. The popular slip ring is replaced by a translation based setup, and the instrumentation cost is reduced by a relaxation of the imaging speed requirement. The dynamic bowtie filter can reduce the dose and in the meantime reduce the required dynamic range of detectors which would decrease the cost of detectors. Our initial study shows that the CT and dynamic bowtie methods are feasible. In this project plan, we will further the theory, simulations and experiments of the CT and dynamic bowtie.
一方面新型低成本、可移动CT成像设备是发展中国家偏远地区、战场、军事机构等亟需;另一方面CT新技术需优先考虑降低辐射剂量。项目提出一种射线源和平板探测器相对平行移动扫描的内CT方法和一种高密度液体材料的动态Bowtie(BT)滤波新技术,在简化CT扫描仪系统结构的同时采用动态BT降低辐射剂量和探测器动态范围需求,从而降低系统成本。1次(1T)直线运动CT扫描与数字射线分层照相扫描运动相同,初步研究表明采用2次(2T)和3次(3T)直线运动扫描时重建CT图像效果理想;动态BT为在液体滤波器(HBT)中放置"气泡"型滤波器(LBT),LBT与扫描对象外形相关,当LBT与CT扫描同步旋转时实现动态滤波,初步研究表明该动态BT能较大降低探测数据动态范围。项目组将在现有研究基础上,继续针对锥束变视场内CT图像重建算法、动态BT实现方法等开展相关理论、仿真和试验研究,期望形成一套新型CT的理论和方法。
结项摘要
本课题研究一种直线扫描CT的扫描方式和图像重建算法,可应用于可移动、便携式CT扫描成像系统。采用射线源和探测器平行直线运动扫描方式,CT扫描装置不使用传统医用CT的滑环部件,可简化扫描装置结构,降低系统成本,为偏远地区、战场、军事机构等亟需的可移动CT成像需求提供一种解决方案。另外,为减小CT扫描X射线辐射剂量,本课题同时研究一种动态Bowtie(BT)滤波器技术。该动态BT结构是在高密度液体滤波器(HBT)中放置“气泡”型滤波器(WBT),WBT与扫描对象外形相关,当WBT与CT扫描同步旋转时实现动态滤波,从而降低CT扫描辐射剂量和CT系统探测器动态范围需求。.课题建立了直线扫描CT模型,分析了几何扫描参数,搭建了直线扫描CT试验平台,完成了扫描控制、数据采集、数据校正等程序开发,实现了直线扫描CT成像。研究结果表明1次(1T)直线运动CT扫描与数字射线分层照相(CL)扫描运动相同,采用2次(2T)和3次(3T)直线运动扫描时重建CT图像效果理想;提出了基于直线轨迹扫描反投影滤波(BPF)图像重建算法;提出线性PI线概念和理论,随后证明了多段直线扫描理论上可以采用BPF算法实现精确重建。课题同时研究了工业无损检测用直线扫描CL技术,提出一种正交直线扫描CL成像技术和一种正交电子直线扫描CL成像技术,以满足CL成像在两个正交方向上检测分辨率需求。.课题以锥束CT扫描中间平面为基础,根据射线穿过动态BT并透射均匀衰减检测对象时到达探测器的光子通量一致条件推导出锥束CT动态BT的设计理论;构建了锥束CT系统的蒙特卡罗仿真框架,对一个包含反射靶X射线源、目标试样和动态BT的CT系统进行了仿真研究,结果表明CT扫描过程中X射线动态范围减小100多倍,辐射剂量减少了76%,CT重建图像质量有一定改善。.课题研究的直线扫描CT理论,研制的CT试验系统,为一种新型CT扫描产品开发提供了技术支撑;研究的正交直线扫描CL理论,研制的CL试验系统,可推广应用于平板类零部件X射线层析成像;研究设计的CT动态BT,可推广应用于现行医用CT成像。
项目成果
期刊论文数量(20)
专著数量(0)
科研奖励数量(2)
会议论文数量(3)
专利数量(14)
Study of the Microfocus X-Ray Tube Based on a Point-Like Target Used for Micro-Computed Tomography.
基于点状靶的微计算机断层扫描微焦点X射线管的研究
- DOI:10.1371/journal.pone.0156224
- 发表时间:2016
- 期刊:PloS one
- 影响因子:3.7
- 作者:Zhou R;Zhou X;Li X;Cai Y;Liu F
- 通讯作者:Liu F
Image reconstruction model for the exterior problem of computed tomography based on weighted directional total variation
基于加权方向全变分的计算机断层扫描外部问题图像重建模型
- DOI:10.1016/j.apm.2017.07.057
- 发表时间:2017-12
- 期刊:APPLIED MATHEMATICAL MODELLING
- 影响因子:5
- 作者:Guo Yumeng;Zeng Li;Wang Chengxiang;Zhang Lingli
- 通讯作者:Zhang Lingli
CT射线动态滤波器研究综述
- DOI:--
- 发表时间:2017
- 期刊:仪器仪表学报
- 影响因子:--
- 作者:朱慧杰;高富强;刘丰林
- 通讯作者:刘丰林
An Improved Approach of Mesh Segmentation to Extract Feature Regions.
一种改进的网格分割提取特征区域的方法
- DOI:10.1371/journal.pone.0139488
- 发表时间:2015
- 期刊:PloS one
- 影响因子:3.7
- 作者:Gu M;Duan L;Wang M;Bai Y;Shao H;Wang H;Liu F
- 通讯作者:Liu F
相对平行直线扫描计算机分层成像研究
- DOI:10.3788/aos201838.1211002
- 发表时间:2018
- 期刊:光学学报
- 影响因子:--
- 作者:王少宇;伍伟文;龚长城;刘丰林
- 通讯作者:刘丰林
数据更新时间:{{ journalArticles.updateTime }}
{{
item.title }}
{{ item.translation_title }}
- DOI:{{ item.doi || "--"}}
- 发表时间:{{ item.publish_year || "--" }}
- 期刊:{{ item.journal_name }}
- 影响因子:{{ item.factor || "--"}}
- 作者:{{ item.authors }}
- 通讯作者:{{ item.author }}
数据更新时间:{{ journalArticles.updateTime }}
{{ item.title }}
- 作者:{{ item.authors }}
数据更新时间:{{ monograph.updateTime }}
{{ item.title }}
- 作者:{{ item.authors }}
数据更新时间:{{ sciAawards.updateTime }}
{{ item.title }}
- 作者:{{ item.authors }}
数据更新时间:{{ conferencePapers.updateTime }}
{{ item.title }}
- 作者:{{ item.authors }}
数据更新时间:{{ patent.updateTime }}
其他文献
一种广角扇束扫描γ射线工业CT实验仪
- DOI:--
- 发表时间:--
- 期刊:核技术
- 影响因子:--
- 作者:蔡玉芳;刘丰林
- 通讯作者:刘丰林
聚合物成型形态的计算机层析图像
- DOI:--
- 发表时间:--
- 期刊:光学精密工程12(3): 111~114,2004
- 影响因子:--
- 作者:李礼夫*;刘丰林
- 通讯作者:刘丰林
其他文献
{{
item.title }}
{{ item.translation_title }}
- DOI:{{ item.doi || "--" }}
- 发表时间:{{ item.publish_year || "--"}}
- 期刊:{{ item.journal_name }}
- 影响因子:{{ item.factor || "--" }}
- 作者:{{ item.authors }}
- 通讯作者:{{ item.author }}

内容获取失败,请点击重试

查看分析示例
此项目为已结题,我已根据课题信息分析并撰写以下内容,帮您拓宽课题思路:
AI项目摘要
AI项目思路
AI技术路线图

请为本次AI项目解读的内容对您的实用性打分
非常不实用
非常实用
1
2
3
4
5
6
7
8
9
10
您认为此功能如何分析更能满足您的需求,请填写您的反馈:
刘丰林的其他基金
源直线扫描CT(STCT)成像研究
- 批准号:62171067
- 批准年份:2021
- 资助金额:57 万元
- 项目类别:面上项目
相似国自然基金
{{ item.name }}
- 批准号:{{ item.ratify_no }}
- 批准年份:{{ item.approval_year }}
- 资助金额:{{ item.support_num }}
- 项目类别:{{ item.project_type }}
相似海外基金
{{
item.name }}
{{ item.translate_name }}
- 批准号:{{ item.ratify_no }}
- 财政年份:{{ item.approval_year }}
- 资助金额:{{ item.support_num }}
- 项目类别:{{ item.project_type }}