Improved setup and positioning accuracy using a three-point customized cushion/mask/bite-block immobilization system for stereotactic reirradiation of head and neck cancer.
Improved setup and positioning accuracy using a three-point customized cushion/mask/bite-block immobilization system for stereotactic reirradiation of head and neck cancer.
复制标题
DOI:
10.1120/jacmp.v17i3.6038
复制
发表时间:
2016-05-08
影响因子:
2.1
通讯作者:
Phan J
中科院分区:
文献类型:
--
作者:
Wang H;Wang C;Tung S;Dimmitt AW;Wong PF;Edson MA;Garden AS;Rosenthal DI;Fuller CD;Gunn GB;Takiar V;Wang XA;Luo D;Yang JN;Wong J;Phan J
The purpose of this study was to investigate the setup and positioning uncertainty of a custom cushion/mask/bite‐block (CMB) immobilization system and determine PTV margin for image‐guided head and neck stereotactic ablative radiotherapy (HN‐SABR). We analyzed 105 treatment sessions among 21 patients treated with HN‐SABR for recurrent head and neck cancers using a custom CMB immobilization system. Initial patient setup was performed using the ExacTrac infrared (IR) tracking system and initial setup errors were based on comparison of ExacTrac IR tracking system to corrected online ExacTrac X‐rays images registered to treatment plans. Residual setup errors were determined using repeat verification X‐ray. The online ExacTrac corrections were compared to cone‐beam CT (CBCT) before treatment to assess agreement. Intrafractional positioning errors were determined using prebeam X‐rays. The systematic and random errors were analyzed. The initial translational setup errors were , , and in AP, CC, and LR directions, respectively, with a three‐dimensional (3D) vector of . The initial rotational errors were up to 2.4° if 6D couch is not available. CBCT agreed with ExacTrac X‐ray images to within 2 mm and 2.5°. The intrafractional uncertainties were , , and in AP, CC, and LR directions, respectively, and , , and in yaw, roll, and pitch direction, respectively. The translational vector was . The calculated PTV margins were within 1.6 mm when using image guidance for online setup correction. The use of image guidance for online setup correction, in combination with our customized CMB device, highly restricted target motion during treatments and provided robust immobilization to ensure minimum dose of 95% to target volume with 2.0 mm PTV margin for HN‐SABR. PACS number(s): 87.55.ne
登录
查看更多内容
DOI:
10.1016/j.ijrobp.2006.11.010
发表时间:
2007-03-15
影响因子:
7
作者:
Meyer, Juergen;Wilbert, Juergen;Flentje, Michael
通讯作者:
Flentje, Michael
影响因子:
3.5
作者:
van Herk, M
通讯作者:
van Herk, M
DOI:
10.1016/s0958-3947(00)00059-5
发表时间:
2001-01-01
期刊:
Medical dosimetry : official journal of the American Association of Medical Dosimetrists
影响因子:
--
作者:
Saw, C B;Yakoob, R;Ayyangar, K M
通讯作者:
Ayyangar, K M
影响因子:
1.2
作者:
Jin, Jian-Yue;Yin, Fang-Fang;Solberg, Timothy D.
通讯作者:
Solberg, Timothy D.
DOI:
10.1016/j.ijrobp.2010.06.022
发表时间:
2011-05-01
影响因子:
7
作者:
Tryggestad, Erik;Christian, Matthew;Kleinberg, Lawrence
通讯作者:
Kleinberg, Lawrence