Challenges and limitations of patient-specific vascular phantom fabrication using 3D Polyjet printing.
Challenges and limitations of patient-specific vascular phantom fabrication using 3D Polyjet printing.
复制标题
DOI:
10.1117/12.2042266
复制
发表时间:
2014-03-13
期刊:
影响因子:
--
通讯作者:
Rudin S
中科院分区:
文献类型:
--
作者:
Ionita CN;Mokin M;Varble N;Bednarek DR;Xiang J;Snyder KV;Siddiqui AH;Levy EI;Meng H;Rudin S
Additive manufacturing (3D printing) technology offers a great opportunity towards development of patient-specific vascular anatomic models, for medical device testing and physiological condition evaluation. However, the development process is not yet well established and there are various limitations depending on the printing materials, the technology and the printer resolution. Patient-specific neuro-vascular anatomy was acquired from computed tomography angiography and rotational digital subtraction angiography (DSA). The volumes were imported into a Vitrea 3D workstation (Vital Images Inc.) and the vascular lumen of various vessels and pathologies were segmented using a “marching cubes” algorithm. The results were exported as Stereo Lithographic (STL) files and were further processed by smoothing, trimming, and wall extrusion (to add a custom wall to the model). The models were printed using a Polyjet printer, Eden 260V (Objet-Stratasys). To verify the phantom geometry accuracy, the phantom was reimaged using rotational DSA, and the new data was compared with the initial patient data. The most challenging part of the phantom manufacturing was removal of support material. This aspect could be a serious hurdle in building very tortuous phantoms or small vessels. The accuracy of the printed models was very good: distance analysis showed average differences of 120 μm between the patient and the phantom reconstructed volume dimensions. Most errors were due to residual support material left in the lumen of the phantom. Despite the post-printing challenges experienced during the support cleaning, this technology could be a tremendous benefit to medical research such as in device development and testing.
登录
查看更多内容
影响因子:
3.8
作者:
Allard, Louise;Soulez, Gilles;Cloutier, Guy
通讯作者:
Cloutier, Guy
影响因子:
2.6
作者:
Hayes, Paul D.;Sadat, Umar;Boyle, Jonathan R.
通讯作者:
Boyle, Jonathan R.
影响因子:
3.8
作者:
Schafer, Sebastian;Hoffmann, Kenneth R.;Dmochowski, Jacek
通讯作者:
Dmochowski, Jacek
影响因子:
37.8
作者:
Go AS;Mozaffarian D;Roger VL;Benjamin EJ;Berry JD;Borden WB;Bravata DM;Dai S;Ford ES;Fox CS;Franco S;Fullerton HJ;Gillespie C;Hailpern SM;Heit JA;Howard VJ;Huffman MD;Kissela BM;Kittner SJ;Lackland DT;Lichtman JH;Lisabeth LD;Magid D;Marcus GM;Marelli A;Matchar DB;McGuire DK;Mohler ER;Moy CS;Mussolino ME;Nichol G;Paynter NP;Schreiner PJ;Sorlie PD;Stein J;Turan TN;Virani SS;Wong ND;Woo D;Turner MB;American Heart Association Statistics Committee and Stroke Statistics Subcommittee
通讯作者:
American Heart Association Statistics Committee and Stroke Statistics Subcommittee
影响因子:
3.5
作者:
Cebral, J. R.;Mut, F.;Putman, C. M.
通讯作者:
Putman, C. M.