Flu@home: the Comparative Accuracy of an At-Home Influenza Rapid Diagnostic Test Using a Prepositioned Test Kit, Mobile App, Mail-in Reference Sample, and Symptom-Based Testing Trigger.
Flu@home: the Comparative Accuracy of an At-Home Influenza Rapid Diagnostic Test Using a Prepositioned Test Kit, Mobile App, Mail-in Reference Sample, and Symptom-Based Testing Trigger.
复制标题
DOI:
10.1128/jcm.02070-21
复制
发表时间:
2022-03-16
影响因子:
9.4
通讯作者:
Thompson M
中科院分区:
文献类型:
--
作者:
Kotnik JH;Cooper S;Smedinghoff S;Gade P;Scherer K;Maier M;Juusola J;Ramirez E;Naraghi-Arani P;Lyon V;Lutz B;Thompson M
At-home testing with rapid diagnostic tests (RDTs) for respiratory viruses could facilitate early diagnosis, guide patient care, and prevent transmission. Such RDTs are best used near the onset of illness when viral load is highest and clinical action will be most impactful, which may be achieved by at-home testing. We evaluated the diagnostic accuracy of the QuickVue Influenza A+B RDT in an at-home setting. A convenience sample of 5,229 individuals who were engaged with an on-line health research platform were prospectively recruited throughout the United States. “Flu@home” test kits containing a QuickVue RDT and reference sample collection and shipping materials were prepositioned with participants at the beginning of the study. Participants responded to daily symptom surveys. If they reported experiencing cough along with aches, fever, chills, and/or sweats, they used their flu@home kit following instructions on a mobile app and indicated what lines they saw on the RDT. Of the 976 participants who met criteria to use their self-collection kit and completed study procedures, 202 (20.7%) were positive for influenza by qPCR. The RDT had a sensitivity of 28% (95% CI = 21 to 36) and specificity of 99% (98 to 99) for influenza A, and 32% (95% CI = 20 to 46) and 99% (95% CI = 98 to 99), for influenza B. Our results support the concept of app-supported, prepositioned at-home RDT kits using symptom-based triggers, although it cannot be recommended with the RDT used in this study. Further research is needed to determine ways to improve the accuracy and utility of home-based testing for influenza.
影响因子:
3.7
作者:
Zigman Suchsland ML;Rahmatullah I;Lutz B;Lyon V;Huang S;Kline E;Graham C;Cooper S;Su P;Smedinghoff S;Chu HY;Sewalk K;Brownstein JS;Thompson MJ;Seattle Flu Study investigators
通讯作者:
Seattle Flu Study investigators
影响因子:
3.7
作者:
Gordon A;Videa E;Saborío S;López R;Kuan G;Balmaseda A;Harris E
通讯作者:
Harris E