Integration of Compliance Chambers into Diaphragm Displacement Pump to Double the Pumping Flow of Pediatric Paracorporeal Pulsatile Ventricular Assist Device

Integration of Compliance Chambers into Diaphragm Displacement Pump to Double the Pumping Flow of Pediatric Paracorporeal Pulsatile Ventricular Assist Device
将顺应室集成到隔膜排量泵中,使儿科体外脉动心室辅助装置的泵流量加倍
批准号:
10761399
负责人:
Stephen R Topaz
金额:
$29.59万
依托单位:
依托单位国家:
美国
项目类别:
财政年份:
2023
资助国家:
美国
项目状态:
未结题
起止时间:
2023-08-10 至 2025-01-31

项目摘要

项目成果

Stephen R Topaz的其他基金

相似基金

相关文献

中文摘要
翻译
ParacorpoReal柏林心脏EXCOR是FDA批准的唯一一种用于 儿科病人。这种脉动隔膜柱塞泵(DDP)体积小/重量轻,便于儿科 耐心地走动。然而,EXCOR的效率只有50%,因为它以不同的速度抽出和泵血 次数(间断脉动流)。这会产生很高的峰值血流速度,这可能会导致血液损伤。 一种准心脏持续流动儿科VAD也已用于较小的儿童。这台离心泵 由于通过引流/输液插管的持续流动,效率很高,但PediMag泵的泵头 必须连接到笨重/笨重的马达,这会阻碍行走。我们之前开发出了一种经根尖到 主动脉(TAA)双腔插管(DLC)用于微创非卧床LVAD,效果良好 96小时初生羔羊的性能/血液相容性。我们的最终目标是开发一种高效的、最低限度的 为儿科患者设计的侵入性准心脏左冠状动脉成形术系统,它结合了小尺寸/重量(行走) 电流间断脉动流量泵(例如EXCOR)的电势)和电流的高效率 连续流泵(如PediMag)。使能技术是一种顺应式隔膜活塞泵 (CDDP),它将顺应室集成到引流和输液出口,以使血流量加倍。 CDDP将是高性能的,因为:1)不间断/连续的血流;2)输液/引流 降低cDDP后负荷/增加cDDP预负荷的顺应室。较低高峰引流/输液 CDDP的流动也将减少血液创伤。初步数据显示,增加合规室 泵送流量由1 L/分钟增加到2 6 L/分钟,峰值流量降低。第一阶段SBIR的目标是 设计并制造了具有最佳顺应室尺寸的cDDP工作样机。这个cDDP将是 用我们之前开发的TAA DLC在羔羊身上进行了测试。具体目标1:设计、制造和测试 测试cDDP。顺应室将集成到cDDP引流和输液出口中。CDDP 将由聚碳酸酯外壳制成,中间带有聚氨基甲酸酯隔膜。三尖瓣可以 将cDDP外壳连接到两个小型硅胶顺应室。最终的原型将进行测试,以确定 在37%甘油模拟环路中1周,以获得性能/可靠性/耐用性。具体目标2:测试cDDP 在羔羊身上工作的原型。CDDP将与TAA DLC相结合,以形成侵入性较小的, 将在10-15公斤的羔羊(n=9)身上进行测试,以评估6小时性能/可靠性和 最初的生物相容性。原型设计/制造/台架测试将在W-Z生物技术公司进行,羔羊 研究将在肯塔基大学进行。我们的cDDP不是对现有技术进行微调,而是 一项新颖的发明,它将使搏动的准心脏VAD具有双倍的效率。这项技术可以 也可用于成人,并可能显著影响心源性休克/过渡到心脏移植治疗。
英文摘要
The paracorporeal Berlin Heart EXCOR is the only FDA-approved ventricular assist device (VAD) for pediatric patients. This pulsatile diaphragm displacement pump (DDP) is small/light weight to facilitate pediatric patient ambulation. However, EXCOR efficiency is only 50% since it withdraws and pumps blood at different times (interrupted pulsatile flow). This generates a high peak blood flow rate, which may cause blood damage. A paracorporeal continuous flow PediMag VAD has also been used in smaller children. This centrifugal pump is highly efficient due to the constant flow through the drainage/infusion cannulas, but the PediMag pump head must be attached to a bulky/heavy motor, which hinders ambulation. We previously developed a transapical to aorta (TAA) double lumen cannula (DLC) for a minimally invasive ambulatory LVAD, which showed excellent 96 hr performance/hemocompatibility in neonate lambs. Our ultimate goal is to develop an efficient, minimally invasive, paracorporeal LVAD system for pediatric patients, which combines the small size/weight (ambulation potential) of current interrupted pulsatile flow pump (e.g EXCOR) and the current high efficiency of a continuous flow pump (e.g PediMag). The enabling technology is a compliant diaphragm displacement pump (cDDP), which has compliance chambers integrated into the drainage and infusion outlets to double blood flow. The cDDP will be high performing due to: 1) noninterrupted/continuous blood flow; 2) infusion/drainage compliance chambers that decrease cDDP afterload/increase cDDP preload. The lower peak drainage/infusion flow of the cDDP will also reduce blood trauma. Preliminary data showed that adding compliance chambers increased pumping flow from 1.1 to 2.6 L/min and decreased peak flow rate. The Phase I SBIR objective is to design and fabricate a cDDP working prototype with optimal compliance chambers size. This cDDP will be tested in lambs with our previously developed TAA DLC. Specific Aim 1: To design, fabricate, and bench test a cDDP. Compliance chambers will be integrated into the cDDP drainage and infusion outlets. The cDDP will be made of polycarbonate housing with a polyurethane diaphragm in the middle. A tricuspid valve will connect the cDDP housing to the two small silicone compliance chambers. The final prototype will be tested for 1 week in a 37% glycerin mock loop for performance/reliability/durability. Specific Aim 2: To test the cDDP working prototype in lambs. The cDDP will be combined with the TAA DLC to form a less invasive, ambulatory LVAD, which will be tested in 10-15 kg lambs (n=9) to evaluate 6 hr performance/reliability and initial biocompatibility. Prototype design/fabrication/bench testing will be done at W-Z Biotech, and the lamb studies will be done at the University of Kentucky. Rather than fine-tuning existing technology, our cDDP is a novel invention, which will enable a pulsatile paracorporeal VAD with doubled efficiency. This technology can also be used in adults and may significantly impact cardiogenic shock/bridge to heart transplant management.
期刊论文(0)
专著(0)
科研奖励(0)
会议论文
Pediatric Transapical Double Lumen Cannula with Integrated Compliance Chambers Doubles Flow of Paracorporeal Pulsatile VAD
  • 批准号:
    10699790
  • 项目类别:
  • 资助金额:
    $27.54万
  • 财政年份:
    2023
  • 负责人:
    Stephen R Topaz
  • 依托单位:
Development of a Minimally Invasive Single Cannulation, Compact Single Port Pulsatile Ventricular Assist Device (sppVAD) for Total LV Support
  • 批准号:
    10259308
  • 项目类别:
  • 资助金额:
    $22.5万
  • 财政年份:
    2021
  • 负责人:
    Stephen R Topaz
  • 依托单位:
Development of Percutaneous DLC for Total Cavo-pulmonary Assistance
  • 批准号:
    9141450
  • 项目类别:
  • 资助金额:
    $45.76万
  • 财政年份:
    2016
  • 负责人:
    Stephen R Topaz
  • 依托单位:
Development of TransApical to Aorta Double Lumen Cannula for a Neonate LVAD
  • 批准号:
    8712075
  • 项目类别:
  • 资助金额:
    $14.88万
  • 财政年份:
    2014
  • 负责人:
    Stephen R Topaz
  • 依托单位:
海外基金