Volume of preclinical xenograft tumors is more accurately assessed by ultrasound imaging than manual caliper measurements.
Volume of preclinical xenograft tumors is more accurately assessed by ultrasound imaging than manual caliper measurements.
复制标题
DOI:
10.7863/jum.2010.29.6.891
复制
发表时间:
2010-06
期刊:
影响因子:
--
通讯作者:
Manning HC
中科院分区:
文献类型:
--
作者:
Ayers GD;McKinley ET;Zhao P;Fritz JM;Metry RE;Deal BC;Adlerz KM;Coffey RJ;Manning HC
Volume of subcutaneous xenograft tumors is an important metric of disease progression and response to therapy in preclinical drug development. Non-invasive imaging technologies suitable for measuring xenograft volume are increasingly available, yet manual calipers, which are susceptible to inaccuracy and bias, are routinely employed. The goal of this study was to quantify and compare the accuracy, precision, and inter-rater variability of xenograft tumor volume assessment by caliper measurements and ultrasound imaging. Subcutaneous xenograft tumors derived from human colorectal cancer cell lines (DLD1, SW620) were generated in athymic nude mice. Experienced independent reviewers segmented three-dimensional ultrasound data sets and collected manual caliper measurements resulting in tumor volumes. Imaging- and caliper-derived volumes were compared to tumor mass, the gold standard, determined following resection. Bias, precision and inter-rater differences were estimated for each mouse among reviewers. Bootstrapping was used to estimate mean and confidence intervals of variance components, intra-class correlation coefficients (ICC’s) and confidence intervals for each source of variation. Average deviation from true volume and inter-rater differences were significantly lower for ultrasound volumes compared to caliper volumes. Reviewer ICC’s for ultrasound and caliper measurements were similarly low (1%), yet caliper volume variance was 1.3-fold higher than ultrasound. Ultrasound imaging more accurately, precisely, and reproducibly reflects xenograft tumor volume than caliper measurements. These data suggest that preclinical studies utilizing xenograft burden as a surrogate endpoint measured by ultrasound imaging require up to 30% fewer animals to reach statistical significance compared to analogous studies utilizing caliper measurements.
登录
查看更多内容
DOI:
10.1158/1078-0432.ccr-08-0239
发表时间:
2008-11-15
期刊:
Clinical cancer research : an official journal of the American Association for Cancer Research
影响因子:
--
作者:
Manning HC;Merchant NB;Foutch AC;Virostko JM;Wyatt SK;Shah C;McKinley ET;Xie J;Mutic NJ;Washington MK;LaFleur B;Tantawy MN;Peterson TE;Ansari MS;Baldwin RM;Rothenberg ML;Bornhop DJ;Gore JC;Coffey RJ
通讯作者:
Coffey RJ
影响因子:
2.9
作者:
Cheung, AMY;Brown, AS;Foster, FS
通讯作者:
Foster, FS
影响因子:
3
作者:
TOMAYKO, MM;REYNOLDS, CP
通讯作者:
REYNOLDS, CP
影响因子:
2.9
作者:
He, ZQ;Evelhoch, JL;Sarkar, FH
通讯作者:
Sarkar, FH
影响因子:
11.2
作者:
Graham, KC;Wirtzfeld, LA;Chambers, AF
通讯作者:
Chambers, AF