Ultrasound elastography for carpal tunnel pressure measurement: A cadaveric validation study.
Ultrasound elastography for carpal tunnel pressure measurement: A cadaveric validation study.
复制标题
DOI:
10.1002/jor.23658
复制
发表时间:
2018-01
期刊:
影响因子:
--
通讯作者:
Zhao C
中科院分区:
文献类型:
--
作者:
Kubo K;Zhou B;Cheng YS;Yang TH;Qiang B;An KN;Moran SL;Amadio PC;Zhang X;Zhao C
Carpal tunnel pressure is a key factor in the etiology of carpal tunnel syndrome. Numerous approaches have been conducted to measure carpal tunnel pressure. However, most techniques are invasive and take time and effort. We have developed an innovative approach to noninvasively assess the tunnel pressure by using the ultrasound surface wave elastography (USWE) technique. In a previous study it was shown that the shear wave speed in a tendon increased linearly with increasing tunnel pressure enclosed the tendon in a simple tendon model. This study aimed to examine the relationship between the carpal tunnel pressure and the shear wave speeds inside and outside the carpal tunnel in a human cadaveric model. The result showed that the shear wave speed inside the carpal tunnel increased linearly with created carpal tunnel pressure, while the shear wave speed outside the carpal tunnel remained constant. These findings suggest that noninvasive measurement of carpal tunnel pressure is possible by measuring the shear wave speed in the tendon. After fully establishing this technology and being applicable in clinic, it would be useful in the diagnosis of carpal tunnel syndrome. For that reason, further validation with this technique in both healthy controls and patients with carpal tunnel syndrome is required. For the purpose of deducing the carpal tunnel pressure noninvasively, this study was conducted to evaluate the relationship between the carpal tunnel pressure and the shear wave speeds propagating the tendon inside and outside the carpal tunnel in a human cadaveric model by using the ultrasound surface wave elastography technique. The result showed that the shear wave speed inside the carpal tunnel increased linearly with created carpal tunnel pressure, while the shear wave speed outside the carpal tunnel remained constant.
登录
查看更多内容
影响因子:
2.8
作者:
Filius, Anika;Scheltens, Marjan;Selles, Ruud W.
通讯作者:
Selles, Ruud W.
影响因子:
1.9
作者:
FUCHS, PC;NATHAN, PA;MYERS, LD
通讯作者:
MYERS, LD
影响因子:
3.4
作者:
Cartwright, Michael S.;Hobson-Webb, Lisa D.;Walker, Francis O.
通讯作者:
Walker, Francis O.
影响因子:
2.7
作者:
Chen SF;Lu CH;Huang CR;Chuang YC;Tsai NW;Chang CC;Chang WN
通讯作者:
Chang WN
影响因子:
1.9
作者:
Nakamichi, K;Tachibana, S
通讯作者:
Tachibana, S