Real-time quantitative monitoring of hiPSC-based model of macular degeneration on Electric Cell-substrate Impedance Sensing microelectrodes.
Real-time quantitative monitoring of hiPSC-based model of macular degeneration on Electric Cell-substrate Impedance Sensing microelectrodes.
复制标题
DOI:
10.1016/j.bios.2015.04.079
复制
发表时间:
2015-09-15
影响因子:
12.6
通讯作者:
Dhillon, B.
中科院分区:
文献类型:
--
作者:
Gamal, W.;Borooah, S.;Smith, S.;Underwood, I.;Srsen, V.;Chandran, S.;Bagnaninchi, P. O.;Dhillon, B.
关键词:
Age-related macular degeneration (AMD) is the leading cause of blindness in the developed world. Humanized disease models are required to develop new therapies for currently incurable forms of AMD. In this work, a tissue-on-a-chip approach was developed through combining human induced pluripotent stem cells, Electric Cell–substrate Impedance Sensing (ECIS) and reproducible electrical wounding assays to model and quantitatively study AMD. Retinal Pigment Epithelium (RPE) cells generated from a patient with an inherited macular degeneration and from an unaffected sibling were used to test the model platform on which a reproducible electrical wounding assay was conducted to model RPE damage. First, a robust and reproducible real-time quantitative monitoring over a 25-day period demonstrated the establishment and maturation of RPE layers on the microelectrode arrays. A spatially controlled RPE layer damage that mimicked cell loss in AMD disease was then initiated. Post recovery, significant differences (P<0.01) in migration rates were found between case (8.6±0.46 μm/h) and control cell lines (10.69±0.21 μm/h). Quantitative data analysis suggested this was achieved due to lower cell–substrate adhesion in the control cell line. The ECIS cell–substrate adhesion parameter (α) was found to be 7.8±0.28 Ω1/2 cm for the case cell line and 6.5±0.15 Ω1/2 cm for the control. These findings were confirmed using cell adhesion biochemical assays. The developed disease model-on-a-chip is a powerful platform for translational studies with considerable potential to investigate novel therapies by enabling real-time, quantitative and reproducible patient-specific RPE cell repair studies. hiPSC-RPE model was established and characterised on ECIS microelectrode arrays. A reproducible electrical wound healing assay was used to mimic RPE cell damage. Significant differences in migration rates were found between case and control. Cells recovered through mesenchymal migration mirrored by impedance fluctuations. Case cell line showed significantly higher adhesion than the control cell line.
登录
查看更多内容
影响因子:
3.9
作者:
Lee, Jiyeon;Wang, Yu-Lin;Lele, Tanmay P.
通讯作者:
Lele, Tanmay P.
影响因子:
24.3
作者:
Heijink, I. H.;Brandenburg, S. M.;van Oosterhout, A. J. M.
通讯作者:
van Oosterhout, A. J. M.
DOI:
10.1073/pnas.1202922109
发表时间:
2012-04-10
影响因子:
11.1
作者:
Bilican, Bilada;Serio, Andrea;Chandran, Siddharthan
通讯作者:
Chandran, Siddharthan
影响因子:
4.8
作者:
Han, Jingyan;Liu, Guoquan;Voyno-Yasenetskaya, Tatyana
通讯作者:
Voyno-Yasenetskaya, Tatyana
影响因子:
2.7
作者:
Keese, CR;Bhawe, K;Giaever, I
通讯作者:
Giaever, I