Optical characterization of two-layered turbid media for non-invasive, absolute oximetry in cerebral and extracerebral tissue.

Optical characterization of two-layered turbid media for non-invasive, absolute oximetry in cerebral and extracerebral tissue.
复制标题

DOI:
10.1371/journal.pone.0064095
复制
发表时间:
2013
期刊:
影响因子:
3.7
通讯作者:
Fantini S
Fantini S
中科院分区:
综合性期刊3区
文献类型:
--
作者:
Hallacoglu B;Sassaroli A;Fantini S

文献摘要

参考文献

被引文献

相似文献

We introduce a multi-distance, frequency-domain, near-infrared spectroscopy (NIRS) method to measure the optical coefficients of two-layered media and the thickness of the top layer from diffuse reflectance measurements. This method features a direct solution based on diffusion theory and an inversion procedure based on the Levenberg-Marquardt algorithm. We have validated our method through Monte Carlo simulations, experiments on tissue-like phantoms, and measurements on the forehead of three human subjects. The Monte Carlo simulations and phantom measurements have shown that, in ideal two-layered samples, our method accurately recovers the top layer thickness (L), the absorption coefficient (µa) and the reduced scattering coefficient (µ′s) of both layers with deviations that are typically less than 10% for all parameters. Our method is aimed at absolute measurements of hemoglobin concentration and saturation in cerebral and extracerebral tissue of adult human subjects, where the top layer (layer 1) represents extracerebral tissue (scalp, skull, dura mater, subarachnoid space, etc.) and the bottom layer (layer 2) represents cerebral tissue. Human subject measurements have shown a significantly greater total hemoglobin concentration in cerebral tissue (82±14 µM) with respect to extracerebral tissue (30±7 µM). By contrast, there was no significant difference between the hemoglobin saturation measured in cerebral tissue (56%±10%) and extracerebral tissue (62%±6%). To our knowledge, this is the first time that an inversion procedure in the frequency domain with six unknown parameters with no other prior knowledge is used for the retrieval of the optical coefficients and top layer thickness with high accuracy on two-layered media. Our absolute measurements of cerebral hemoglobin concentration and saturation are based on the discrimination of extracerebral and cerebral tissue layers, and they can enhance the impact of NIRS for cerebral hemodynamics and oxygenation assessment both in the research arena and clinical practice.
DOI: 10.1002/cnm.1162
发表时间: 2008-08-15
影响因子: --
作者:
Dehghani, Hamid;Eames, Matthew E.;Yalavarthy, Phaneendra K.;Davis, Scott C.;Srinivasan, Subhadra;Carpenter, Colin M.;Pogue, Brian W.;Paulsen, Keith D.
通讯作者: Paulsen, Keith D.
DOI: 10.1203/pdr.0b013e318045be99
发表时间: 2007-05-01
期刊: PEDIATRIC RESEARCH
影响因子: 3.6
作者:
Franceschini, Maria Angela;Thaker, Sonal;Grant, P. Ellen
通讯作者: Grant, P. Ellen
DOI: 10.1364/ao.46.001717
发表时间: 2007-04-01
期刊: APPLIED OPTICS
影响因子: 1.9
作者:
Comelli, Daniela;Bassi, Andrea;Zaccanti, Giovanni
通讯作者: Zaccanti, Giovanni
DOI: 10.1117/1.1628242
发表时间: 2004-01-01
影响因子: 3.5
作者:
Choi, J;Wolf, M;Gratton, E
通讯作者: Gratton, E
DOI: 10.1371/journal.pone.0024981
发表时间: 2011-09-21
期刊: PLOS ONE
影响因子: 3.7
作者:
Beauchamp, Michael S.;Beurlot, Michelle R.;Oghalai, John S.
通讯作者: Oghalai, John S.