Advantage of PET/CT in Target Delineation of MRI-negative Cervical Lymph Nodes In Intensity-Modulated Radiation Therapy Planning for Nasopharyngeal Carcinoma.
Advantage of PET/CT in Target Delineation of MRI-negative Cervical Lymph Nodes In Intensity-Modulated Radiation Therapy Planning for Nasopharyngeal Carcinoma.
复制标题
DOI:
10.7150/jca.21582
复制
发表时间:
2017
影响因子:
3.9
通讯作者:
Deng X
中科院分区:
文献类型:
--
作者:
Shen G;Xiao W;Han F;Fan W;Lin XP;Lu L;Zheng L;Yue N;Haffty B;Zhao C;Deng X
Introduction: In intensity-modulated radiation therapy (IMRT) planning for nasopharyngeal carcinoma (NPC), cervical lymph nodes (CLNs) that appear negative on magnetic resonance imaging (MRI) scans can be difficult to target. The purpose of this study was to assess the advantage of 18F-fluorodeoxyglucose positron emission tomography with computed tomography (18F-FDG PET/CT) for distinguishing MRI-negative CLNs and the effect of 18F-FDG PET/CT on diagnosis, target delineation, and dose prescription in IMRT planning for NPC. Methods: Thirty-five NPC patients with 37 MRI-negative CLNs underwent 18F-FDG PET/CT imaging before treatment. Ultrasonography-guided fine-needle aspiration cytology (USgFNAC) was performed to examine the pathology of CLNs. The 18F-FDG PET/CT and cytopathological results were compared, and the diagnostic accuracy of 18F-FDG PET/CT was calculated. The cytopathologically confirmed CLNs were delineated and treated as the gross tumor volume of lymph nodes (denoted as GTVnd). Results: Nineteen of the 37 MRI-negative CLNs were positive on 18F-FDG PET/CT, and metastasis was confirmed by USgFNAC in 16 CLNs. Of the remaining 18 18F-FDG PET/CT-negative lymph nodes, metastasis was confirmed in one. The diagnostic accuracy, sensitivity, and specificity of 18F-FDG PET/CT were 89.2%, 94.1%, and 85.0%, respectively. The positive and negative predictive values were 84.2% and 94.4%, respectively. With a median follow-up of 48.3 months, no relapse was observed among the 18F-FDG PET/CT-positive CLNs with metastasis confirmed by USgFNAC and treated as GTVnd. Conclusion: 18F-FDG PET/CT had high accuracy, sensitivity, and specificity for distinguishing MRI-negative CLNs. 18F-FDG PET/CT-positive CLNs could reasonably be categorized as high-risk clinical tumor volume in IMRT planning for NPC.
登录
查看更多内容
影响因子:
1.9
作者:
Sigg, MB;Steinert, H;Eyrich, GK
通讯作者:
Eyrich, GK
影响因子:
3.9
作者:
Xue, Fen;Hu, Chaosu;He, Xiayun
通讯作者:
He, Xiayun
影响因子:
2.6
作者:
DON, DM;ANZAI, Y;CALCATERRA, TC
通讯作者:
CALCATERRA, TC
DOI:
10.1186/s40644-016-0096-y
发表时间:
2016-11-03
期刊:
Cancer imaging : the official publication of the International Cancer Imaging Society
影响因子:
--
作者:
Hempel JM;Kloeckner R;Krick S;Pinto Dos Santos D;Schadmand-Fischer S;Boeßert P;Bisdas S;Weber MM;Fottner C;Musholt TJ;Schreckenberger M;Miederer M
通讯作者:
Miederer M
影响因子:
5.7
作者:
Sun, Xueming;Su, Shengfa;Lu, Taixiang
通讯作者:
Lu, Taixiang